Three cases of resuscitative endovascular balloon occlusion of the aorta (REBOA) in austere pre-hospital environmenttechnical and methodological aspects

被引:41
作者
de Schoutheete, J. C. [1 ,2 ]
Fourneau, I. [3 ]
Waroquier, F. [1 ]
De Cupere, L. [1 ]
O'Connor, M. [4 ]
Van Cleynenbreugel, K. [1 ]
Ceccaldi, J. C. [1 ]
Nijs, S. [2 ]
机构
[1] Astrid Mil Hosp, Burn Unit, B-1120 Brussels, Belgium
[2] Univ Hosp Leuven, Dept Trauma Surg, B-3000 Leuven, Belgium
[3] Univ Hosp Leuven, Dept Vasc Surg, B-3000 Leuven, Belgium
[4] US Army, Surg Detachment 175, Ft Campbell, KY USA
关键词
Resuscitative endovascular balloon occlusion of the aorta; REBOA; Partial REBOA; Shock; Trauma; Pre-hospital; Austere surgery; INJURY SEVERITY SCORE; TRAUMA; MODEL; COMPLICATIONS; OUTCOMES; SKILLS; CARE;
D O I
10.1186/s13017-018-0213-2
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BackgroundThe present paper describes three cases where ER-REBOA (R) was used with partial aorta occlusion (AO), by performing a partial resuscitative endovascular balloon occlusion of the aorta or pREBOA, in an austere pre-hospital military environment.In addition, because no specific REBOA algorithm for pre-hospital environment exists yet, this paper seeks to fill this gap, proposing a new pragmatic REBOA algorithm.MethodsBelgian Special Operations Surgical Team applied REBOA in three patients according to a decisional algorithm, based on the MIST acronym used for trauma patients. Only 3ml, in the first instance, was inflated in the balloon to get AO. The balloon was then progressively deflated, and reperfusion was tracked through changes of end-tidal carbon dioxide (EtCO2).ResultsSystolic blood pressure (SBP) before ER-REBOA (R) placement was not higher than 60mmHg. However, within the first 5min after AO, SBP improved in all three cases. Due to the aortic compliance, a self-made pREBOA was progressively achieved while proximal SBP was raising with intravenous fluid infusion. Afterwards, during deflation, a steep inflection point was observed in SBP and EtCO2.ConclusionsER-REBOA (R) is suitable for use in an austere pre-hospital environment. The MIST acronym can be helpful to select the patients for which it could be beneficial. REBOA can also be performed with pREBOA in a dynamic approach, inflating only 3mL in the balloon and using the aortic compliance. Furthermore, while proximal SBP can be convenient to follow the occlusion, EtCO2 can be seen as an easy and interesting marker to follow the reperfusion.
引用
收藏
页数:11
相关论文
共 44 条
[11]   Contemporary outcomes of lower extremity vascular repairs extending below the knee: A multicenter retrospective study [J].
Fortuna, Gerald ;
DuBose, Joseph J. ;
Mendelsberg, Ranan ;
Inaba, Kenji ;
Haider, Ansab ;
Joseph, Bellal ;
Skarupa, David ;
Selleck, Matthew J. ;
O'Callaghan, Thomas A. ;
Charlton-Ouw, Kristofer .
JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2016, 81 (01) :63-70
[12]   Resuscitative Endovascular Balloon Occlusion of the Aorta in trauma: a systematic review of the literature [J].
Gamberini, Emiliano ;
Coccolini, Federico ;
Tamagnini, Beatrice ;
Martino, Costanza ;
Albarello, Vittorio ;
Benni, Marco ;
Bisulli, Marcello ;
Fabbri, Nicola ;
Horer, Tal Martin ;
Ansaloni, Luca ;
Coniglio, Carlo ;
Barozzi, Marco ;
Agnoletti, Vanni .
WORLD JOURNAL OF EMERGENCY SURGERY, 2017, 12
[13]   AIS 2005:: A contemporary injury scale [J].
Gennarelli, Thomas A. ;
Wodzin, Elaine .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2006, 37 (12) :1083-1091
[14]  
Hodgetts T, 1997, TRAUMA RULES
[15]   A case of partial aortic balloon occlusion in an unstable multi-trauma patient [J].
Horer, Tal M. ;
Cajander, Per ;
Jans, Anders ;
Nilsson, Kristofer F. .
TRAUMA-ENGLAND, 2016, 18 (02) :150-154
[16]   Retrospective study of the effectiveness of Intra-Aortic Balloon Occlusion (IABO) for traumatic haemorrhagic shock [J].
Irahara, Takayuki ;
Sato, Norio ;
Moroe, Yuuta ;
Fukuda, Reo ;
Iwai, Yusuke ;
Unemoto, Kyoko .
WORLD JOURNAL OF EMERGENCY SURGERY, 2015, 10
[17]   Partial resuscitative balloon occlusion of the aorta (P-REBOA): Clinical technique and rationale [J].
Johnson, M. Austin ;
Neff, Lucas P. ;
Williams, Timothy K. ;
DuBose, Joseph J. .
JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2016, 81 (05) :S133-S137
[18]   Resuscitative endovascular balloon occlusion of the aorta for major abdominal venous injury in a porcine hemorrhagic shock model [J].
Lallemand, Michael S. ;
Moe, Donald M. ;
McClellan, John M. ;
Smith, Joshua P. ;
Daab, Leo ;
Marko, Shannon ;
Nam Tran ;
Starnes, Benjamin ;
Martin, Matthew J. .
JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2017, 83 (02) :230-+
[19]   Emergent non-image-guided resuscitative endovascular balloon occlusion of the aorta (REBOA) catheter placement: A cadaver-based study [J].
Linnebur, Megan ;
Inaba, Kenji ;
Haltmeier, Tobias ;
Rasmussen, Todd E. ;
Smith, Jennifer ;
Mendelsberg, Ranan ;
Grabo, Daniel ;
Demetriades, Demetrios .
JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2016, 81 (03) :453-457
[20]  
Manley JD, 2017, J SPEC OPER MED, V17, P1