An approach to integrated data assessment in a proficiency test on the enumeration of Escherichia coli

被引:9
作者
Bremser, W. [1 ]
Luecke, F. -K. [2 ]
Urmetzer, C. [3 ]
Fuchs, E. [4 ]
Leist, U. [4 ]
机构
[1] BAM Fed Inst Mat Res & Testing, Dept Analyt Chem, D-12489 Berlin, Germany
[2] Univ Appl Sci, Dept Nutr Food & Consumer Sci, Fulda, Germany
[3] WESSLING Lab GmbH, Walldorf, Germany
[4] Deutsch Referenzburo Lebensmittel Ringversuche &, Kempten, Germany
关键词
bias; data assessment; Escherichia coli; precision; proficiency testing; statistics; MEASUREMENT UNCERTAINTY; FOOD MICROBIOLOGY;
D O I
10.1111/j.1365-2672.2010.04866.x
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Aims: To develop appropriate statistical approaches to plan and evaluate proficiency tests for the enumeration of Escherichia coli, addressing, in particular, a possible but frequently unavoidable lack of test sample homogeneity. Methods and Results: Each of 50 laboratories analysed two samples of a stabilized suspension of E. coli in duplicate, using various media, inoculation methods, and incubation times and conditions. In parallel, the E. coli suspension was tested by the organiser for homogeneity and stability. Escherichia coli counts followed a log-normal distribution. After eliminating, by Youden analysis, two data sets that were considered outliers and eight data sets for underperformance of the laboratories (substantial lack of repeatability), the standard deviation of the mean was about 0 center dot 06 log(10) units. There was no evidence of bimodality of the data. Lack of homogeneity of distribution of bacteria had a strong effect on measurement uncertainty, in addition to laboratory bias and method repeatability. The homogeneity decreases during storage of the individual test vials; this effect could be modelled by the known kinetics of inactivation of micro-organisms. The results were confirmed by Monte Carlo simulations. Conclusions: By a tailored analysis of proficiency testing data, it is possible to distinguish the effect of lack of homogeneity, laboratory bias and method repeatability, on the measurement uncertainty. Significance and Impact of the Study: A statistic tool is provided to solve problems related to lack of stability of microbiological test material and to separate the effects of sample inhomogeneity from the performance of the individual laboratory.
引用
收藏
页码:128 / 138
页数:11
相关论文
共 21 条
[11]   Assessment of measurement uncertainty for quantitative methods of analysis: Comparative assessment of the precision (uncertainty) of bacterial colony counts [J].
Jarvis, Basil ;
Hedges, Alan J. ;
Corry, Janet E. L. .
INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2007, 116 (01) :44-51
[12]   Microbiological proficiency testing: a personal perspective [J].
Jewell, K .
ACCREDITATION AND QUALITY ASSURANCE, 2001, 6 (4-5) :154-159
[13]  
Koch Arthur L., 1994, P248
[14]  
LIGHTFOOT NF, 1998, MICROBIOLOGICAL ANAL, P109
[15]   Estimation of measurement uncertainty in food microbiology: The ISO approach [J].
Lombard, B .
ACCREDITATION AND QUALITY ASSURANCE, 2006, 11 (1-2) :94-100
[16]  
ML Speck, 1992, COMP METH MICR EX FO
[17]  
PETERZ M, 1993, J APPL BACTERIOL, V74, P143
[18]   Development of reference materials for microbiological analysis [J].
Philipp, Wolfgang J. ;
van Iwaarden, Pierre ;
Schimmel, Heinz ;
Meeus, Nele ;
Kollmorgen, Nadine .
ACCREDITATION AND QUALITY ASSURANCE, 2007, 12 (3-4) :134-138
[19]   Measurement uncertainty in water microbiology may not estimate the laboratory's precision [J].
Tillett, HE ;
Sartory, D .
ACCREDITATION AND QUALITY ASSURANCE, 2004, 9 (10) :629-632
[20]  
YOUDEN WJ, 1975, STAT METHODS ASS OFF