A mixed-methods evaluation of continuous electronic fetal monitoring for an extended period

被引:6
作者
Crawford, Alexandra [1 ]
Anyadi, Patrick [1 ]
Stephens, Louise [2 ]
Thomas, Suzanne L. [2 ]
Reid, Holly [3 ]
Higgins, Lucy E. [1 ,2 ]
Warrander, Lynne K. [1 ]
Johnstone, Edward D. [1 ,2 ]
Heazell, Alexander E. P. [1 ,2 ]
机构
[1] Univ Manchester, St Marys Hosp, Maternal & Fetal Hlth Res Ctr, Div Dev Biol & Med,Sch Med Sci,Fac Biol Med & Hlt, Manchester, Lancs, England
[2] Manchester Univ NHS Fdn Trust, St Marys Hosp, Manchester Acad, Hlth Sci Ctr, Manchester, Lancs, England
[3] Univ Manchester, Sch Hlth Sci, Fac Biol Med & Hlth, Div Psychol & Mental Hlth, Manchester, Lancs, England
关键词
cardiotocography; continuous fetal monitoring; feasibility study; maternal anxiety; patient experience; pregnancy; HEART-RATE; CARE;
D O I
10.1111/aogs.13446
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Introduction Continuous fetal monitoring is used to objectively record the fetal heart rate and fetal activity over an extended period of time; however, its feasibility and acceptability to women is currently unknown. The study addressed the hypothesis that continuous fetal monitoring is feasible and acceptable to pregnant women. Material and methods Results Pregnant participants (n = 22) were monitored using a continuous fetal electrocardiography device, the Monica AN24. Signal quality, duration of recording and cardiotocography findings were correlated with maternal and fetal factors. Participants' change in anxiety before and after monitoring was assessed using validated questionnaires. Participants' experiences were explored through a questionnaire (n = 20) and semi-structured interview (n = 13). Recordings were successfully obtained in 19 of the 22 participants (86.3%). The mean recording quality of fetal heart rate was 69.0% (range 17.4%-99.4%) and maternal heart rate was 99.0% (90.9%-100.0%). Recording quality was positively correlated with gestational age (P = 0.05) and negatively correlated with uterine activity and maternal movement (P < 0.001). Overall, participants were satisfied with their experience of continuous fetal monitoring; 30% considered it preferable to intermittent monitoring. Continuous fetal monitoring did not significantly increase maternal anxiety, with a trend towards a reduction in Pregnancy Specific Anxiety score (P = 0.07). Qualitative analysis grouped women's responses into three themes: (a) reassurance and anxiety, (b) the physical device and (c) future developments in continuous fetal monitoring. Conclusions Continuous fetal monitoring is a feasible and acceptable form of monitoring to pregnant women although further practical improvements could be incorporated. Further research is required to assess the ability of continuous fetal monitoring to detect fetal compromise.
引用
收藏
页码:1515 / 1523
页数:9
相关论文
共 25 条
  • [1] Fetal and umbilical Doppler ultrasound in normal pregnancy
    Alfirevic, Zarko
    Stampalija, Tamara
    Gyte, Gillian M. L.
    [J]. COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2010, (08):
  • [2] Feasibility of Noninvasive Fetal Electrocardiographic Monitoring in a Clinical Setting
    Arya, Bhawna
    Govindan, Rathinaswamy
    Krishnan, Anita
    Duplessis, Adre
    Donofrio, Mary T.
    [J]. PEDIATRIC CARDIOLOGY, 2015, 36 (05) : 1042 - 1049
  • [3] Braun V., 2006, QUAL RES PSYCHOL, V3, P77, DOI [10.1191/1478088706qp063oa, DOI 10.1191/1478088706QP063OA]
  • [4] Brown R, 2014, THESIS
  • [5] Professionals' views of fetal-monitoring support the development of devices to provide objective longer-term assessment of fetal wellbeing
    Brown, Rebecca
    Johnstone, Edward D.
    Heazell, Alexander E. P.
    [J]. JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2016, 29 (10) : 1680 - 1686
  • [6] Continuous objective recording of fetal heart rate and fetal movements could reliably identify fetal compromise, which could reduce stillbirth rates by facilitating timely management
    Brown, Rebecca
    Wijekoon, Jayawan H. B.
    Fernando, Anura
    Johnstone, Edward D.
    Heazell, Alexander E. P.
    [J]. MEDICAL HYPOTHESES, 2014, 83 (03) : 410 - 417
  • [7] Cameron R., 2011, The Electronic Journal of Business Research Methods, V9, P96
  • [8] The Use of Triangulation in Qualitative Research
    Carter, Nancy
    Bryant-Lukosius, Denise
    DiCenso, Alba
    Blythe, Jennifer
    Neville, Alan J.
    [J]. ONCOLOGY NURSING FORUM, 2014, 41 (05) : 545 - 547
  • [9] Women's experiences of continuous fetal monitoring - a mixed-methods systematic review
    Crawford, Alexandra
    Hayes, Dexter
    Johnstone, Edward D.
    Heazell, Alexander E. P.
    [J]. ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2017, 96 (12) : 1404 - 1413
  • [10] Maternal Body Mass Index Does Not Affect Performance of Fetal Electrocardiography
    Graatsma, E. Margo
    Miller, Jena
    Mulder, Eduard J. H.
    Harman, Christopher
    Baschat, Ahmet A.
    Visser, Gerard H. A.
    [J]. AMERICAN JOURNAL OF PERINATOLOGY, 2010, 27 (07) : 573 - 577