Dynamic model of wind energy conversion systems with variable speed synchronous generator and full-size power converter for large-scale power system stability studies

被引:21
作者
Sanchez, J. A. [2 ]
Veganzones, C. [1 ]
Martinez, S. [1 ]
Blazquez, F. [1 ]
Herrero, N. [2 ]
Wilhelmi, J. R. [2 ]
机构
[1] Univ Politecn Madrid, ETSII, Dept Elect Engn, Madrid 28006, Spain
[2] Univ Politecn Madrid, ETSICCP, Dept Civil Engn Hydraul & Energy, Madrid 28040, Spain
关键词
modeling; power system stability; wind power generation;
D O I
10.1016/j.renene.2007.06.019
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper presents a dynamic model for variable speed wind energy conversion systems, equipped with a variable pitch wind turbine, a synchronous electrical generator, and a full power converter, specially developed for its use in power system stability studies involving large networks, with a high number of buses and a high level of wind generation penetration. The validity of the necessary simplifications has been contrasted against a detailed model that allows a thorough insight into the mechanical and electrical behavior of the system, and its interaction with the grid. The developed dynamic model has been implemented in a widely used power system dynamics simulation software, PSS/E, and its performance has been tested in a well-documented test power network. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1186 / 1198
页数:13
相关论文
共 20 条
[1]  
Ahlstrom M., 2005, IEEE POWER ENERGY M, V3, p57
[2]   An aggregate model of a grid-connected, large-scale, offshore wind farm for power stability investigations - importance of windmill mechanical system [J].
Akhmatov, V ;
Knudsen, H .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2002, 24 (09) :709-717
[3]  
Anderson P., 2002, Power System Control and Stability
[4]  
[Anonymous], 1979, IEEE T POWER AP SYST, V98, P2047, DOI 10.1109/TPAS.1979.319398
[5]  
[Anonymous], P 14 POW SYST COMP C
[6]   A wind park reduced-order model using singular perturbations theory [J].
Castro, RMG ;
deJesus, JMF .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1996, 11 (04) :735-741
[7]  
CASTRO RMG, 1999, P 13 PSCC POW SYST C, V2, P1302
[8]   Control of permanent-magnet generators applied to variable-speed wind-energy systems connected to the grid [J].
Chinchilla, M ;
Arnaltes, S ;
Burgos, JC .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2006, 21 (01) :130-135
[9]  
DeMeo E. A., 2005, IEEE Power & Energy Magazine, V3, P38, DOI 10.1109/MPAE.2005.1524619
[10]  
Eriksen P. B., 2005, IEEE Power & Energy Magazine, V3, P65, DOI 10.1109/MPAE.2005.1524622