Fault Detection Using ANN for Three-level NPC Inverter fed Induction Motor Drive

被引:0
作者
Lee, Hong Hee [1 ]
Phan Quoc Dzung [2 ]
Truong Phuoc Hoa [2 ]
Le Minh Phuong [2 ]
Nguyen Xuan Bac [2 ]
机构
[1] Univ Ulsan, Sch Elect Engn, Ulsan 680749, South Korea
[2] HCMC Univ Technol, Fac Elect & Elect Engn, Ho Chi Minh City, Vietnam
来源
TENCON 2010: 2010 IEEE REGION 10 CONFERENCE | 2010年
关键词
Pulse-Width-Modulation; Artificial Neural Network; Three-level NPC Inverter; diagnosis; open circuit fault; short circuit fault; VOLTAGE-FED INVERTER; STRATEGY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper is to present the investigation of ANN for fault detection Three-level Neutral Point Clamped (NPC) Inverter fed induction motor drive. Such detection requires only motor currents and DC-link current to be measured for detecting and identifying the power switch in which the open circuit fault or short circuit fault has occurred. Furthermore, a diagnosis controller using ANN for real-time fault detection of power switches is suggested. A computer simulation program is developed using Matlab/Simulink together with the Neural Network Toolbox for training the ANN-controller. This method has been validated experimentally using kit ACE 1104 (DSPACE).
引用
收藏
页码:2148 / 2153
页数:6
相关论文
共 12 条
[11]   Real-time detection of intermittent misfiring in a voltage-fed PWM inverter induction-motor drive [J].
Smith, KS ;
Ran, L ;
Penman, J .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1997, 44 (04) :468-476
[12]   A COMPARATIVE INVESTIGATION OF A 3-PHASE INDUCTION MACHINE DRIVE WITH A COMPONENT MINIMIZED VOLTAGE-FED INVERTER UNDER DIFFERENT CONTROL OPTIONS [J].
VANDERBROECK, HW ;
VANWYK, JD .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1984, 20 (02) :309-320