The Difference-Raman Spectra of Fluid Inclusion of Carbonate Reservoir

被引:5
作者
Li Jing [1 ,2 ]
Zha Ming [1 ]
机构
[1] China Univ Petr, Coll Resources & Informat, Qingdao 266555, Peoples R China
[2] China Univ Petr, Coll Storage & Architecture Engn, Qingdao 266555, Peoples R China
关键词
Fluid inclusion; Carbonate reservoir; Micro-Raman spectra; Difference spectra;
D O I
10.3964/j.issn.1000-0593(2010)09-2397-04
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In the present paper, the authors examined some inclusions of carbonate reservoir by microscopic confocal Raman spectral methods. The measurement temperature of sample was 18 degrees C, -40 degrees C, -80 degrees C and -170 degrees C, respectively. The experimental results show that the original experimental spectral curve of the inclusion was very similar to the original experimental spectral curve of pure main mineral (rock core). Because the size of some inclusions was relatively small or inclusions were hidden deeply in the sample, their Raman spectra signals were often buried in other signals (noises) which stem from main mineral. To overcome the above-mentioned difficulty we used the spectral subtraction method. In Raman spectral experimental process, X-Y scanning and depth profile (Z scanning) were finished around the inclusion. The final results show that spectral subtraction method allows the study of solid samples with high precision because some corrections can be made, if additive properties of spectral quantity are satisfied. Interfering spectral signal from main mineral can be removed, and the inclusion spectrum can be purified.
引用
收藏
页码:2397 / 2400
页数:4
相关论文
共 12 条
[1]   Raman spectra of fluid and crystal mixtures in the systems H2O, H2O-NaCl and H2O-MgCl2 at low temperatures:: Applications to fluid-inclusion research [J].
Bakker, RJ .
CANADIAN MINERALOGIST, 2004, 42 :1283-1314
[2]   THE DETERMINATION OF SULFATE IN FLUID INCLUSIONS USING THE MOLE RAMAN MICROPROBE - APPLICATION TO A KEUPER HALITE AND GEOCHEMICAL CONSEQUENCES [J].
DUBESSY, J ;
GEISLER, D ;
KOSZTOLANYI, C ;
VERNET, M .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1983, 47 (01) :1-10
[3]  
[葛云锦 GE Yunjin], 2008, [岩矿测试, Rock and Mineral Analysis], V27, P207
[4]  
*HUABEI OIL FIELD, 1988, PETR GEOL CHIN, V5
[5]  
[倪培 Ni Pei], 2009, [地学前缘, Earth Science Frontiers], V16, P173
[6]  
Koenig JackL., 1992, Spectroscopy of Polymers (aCS Professional Reference Books)
[7]  
Li N, 1997, LASER SCANNING CONFO
[8]  
Min Gu., 1996, Principles of three dimensional imaging in confocal microscopes
[9]   Cryogenic Raman spectroscopic studies in the system NaCl-CaCl2-H2O and implications for low-temperature phase behavior in aqueous fluid inclusions [J].
Samson, IM ;
Walker, RT .
CANADIAN MINERALOGIST, 2000, 38 :35-43
[10]  
Xu P., 1996, RAMAN SPECTROSCOPY G, P1