Integration of microfluidic sample delivery system on silicon nanowire-based biosensor

被引:7
作者
Hemmila, Samu [1 ,2 ]
Gao, Anran [3 ,4 ]
Lu, Na [3 ,4 ]
Li, Tie [3 ,4 ]
Wang, Yuelin [3 ,4 ]
Kallio, Pasi [1 ,2 ]
机构
[1] Tampere Univ Technol, Tampere 33720, Finland
[2] Inst Biosci & Med Technol, Tampere 33520, Finland
[3] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, State Key Labs Transducer Technol, Shanghai 200050, Peoples R China
[4] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, Sci & Technol Microsyst Lab, Shanghai 200050, Peoples R China
来源
MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS | 2015年 / 21卷 / 03期
基金
中国国家自然科学基金;
关键词
ULTRASENSITIVE ELECTRICAL DETECTION; LABEL-FREE DETECTION; POLY(DIMETHYLSILOXANE); PDMS; NANOSENSORS; SURFACES; DNA; FABRICATION; ARRAYS;
D O I
10.1007/s00542-014-2076-0
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Silicon nanowire-based (SiNW) biosensors have gained a lot of attention during recent years. However, studies often totally neglect, or only briefly describe, the incorporation of microfluidic channel into the sensor architecture, although it is a crucial step towards a real lab-on-chip device. This paper proposes a process that can be applied to integration of microfluidic sample delivery system onto different SiNW biosensors. The sample delivery system includes a hydrophilic channel that enables the use of capillary action in delivering sample directly onto the sensor array, which leads to reduced sample loss, faster detection process, and frees from the use of external pumps. In addition, the microfluidic channel system protects the fragile SiNWs from mechanical shocks, chemical spatters, and dust. The sample delivery system was fabricated of surface treated polydimethylsiloxane (PDMS), using a four-step approach, as follows: (1) master molds for soft lithography were etched onto Si. (2) PDMS replicas of the molds were fabricated and (3) bonded onto example sensor chips using oxygen plasma. (4) Oxygen plasma treatment also enabled the attachment of polyvinylpyrrolidone (PVP) to the sample channel surfaces to synthesize hydrophilic polymer coating. A contact angle for the PVP treated PDMS was 21 after 17 days, indicating the formation of a long-term hydrophilic PDMS surface. Finally, the example SiNW sensor is modified to allow direct real-time detection of thyroid-stimulating hormone (TSH). The sensor was able to detect as low TSH concentration values as 0.5 mIU/l, which indicates a successfully integrated sample delivery system.
引用
收藏
页码:571 / 580
页数:10
相关论文
共 24 条
[1]   Highly stable hydrophilic surfaces of PDMS thin layer obtained by UV radiation and oxygen plasma treatments [J].
Atayde, Cleuson de Menezes ;
Doi, Ioshiaki .
PHYSICA STATUS SOLIDI C: CURRENT TOPICS IN SOLID STATE PHYSICS, VOL 7, NO 2, 2010, 7 (02) :189-192
[2]  
Foltmann H., 2008, Drug Delivery Technology, V8, P22
[3]   Silicon-Nanowire-Based CMOS-Compatible Field-Effect Transistor Nanosensors for Ultrasensitive Electrical Detection of Nucleic Acids [J].
Gao, Anran ;
Lu, Na ;
Dai, Pengfei ;
Li, Tie ;
Pei, Hao ;
Gao, Xiuli ;
Gong, Yibin ;
Wang, Yuelin ;
Fan, Chunhai .
NANO LETTERS, 2011, 11 (09) :3974-3978
[4]   Silicon nanowire arrays for label-free detection of DNA [J].
Gao, Zhiqiang ;
Agarwal, Ajay ;
Trigg, Alastair D. ;
Singh, Navab ;
Fang, Cheng ;
Tung, Chih-Hang ;
Fan, Yi ;
Buddharaju, Kavitha D. ;
Kong, Jinming .
ANALYTICAL CHEMISTRY, 2007, 79 (09) :3291-3297
[5]   Direct ultrasensitive electrical detection of DNA and DNA sequence variations using nanowire nanosensors [J].
Hahm, J ;
Lieber, CM .
NANO LETTERS, 2004, 4 (01) :51-54
[6]   POLYVINYLPYRROLIDONE AS A BLOCKING-AGENT IN IMMUNOCHEMICAL STUDIES [J].
HAYCOCK, JW .
ANALYTICAL BIOCHEMISTRY, 1993, 208 (02) :397-399
[7]   Rapid, simple, and cost-effective treatments to achieve long-term hydrophilic PDMS surfaces [J].
Hemmila, Samu ;
Cauich-Rodriguez, Juan V. ;
Kreutzer, Joose ;
Kallio, Pasi .
APPLIED SURFACE SCIENCE, 2012, 258 (24) :9864-9875
[8]   A thyroid-stimulating hormone immuno-electrode [J].
Lin, ZH ;
Shen, GL ;
Miao, Q ;
Yu, RQ .
ANALYTICA CHIMICA ACTA, 1996, 325 (1-2) :87-92
[9]  
Liu YX, 2013, PLOS ONE, V8, DOI [10.1371/journal.pone.0065361, 10.1371/journal.pone.0076105, 10.1371/journal.pone.0063447, 10.4161/psb.23864, 10.4161/psb.25079]
[10]   Long term hydrophilic coating on poly(dimethylsiloxane) substrates for microfluidic applications [J].
Maheshwari, Nidhi ;
Kottantharayil, Anil ;
Kumar, Mahesh ;
Mukherji, Soumyo .
APPLIED SURFACE SCIENCE, 2010, 257 (02) :451-457