Dialysis adequacy predictions using a machine learning method

被引:16
作者
Kim, Hyung Woo [1 ]
Heo, Seok-Jae [2 ]
Kim, Jae Young [1 ,3 ]
Kim, Annie [2 ]
Nam, Chung-Mo [2 ,4 ]
Kim, Beom Seok [1 ]
机构
[1] Yonsei Univ, Coll Med, Dept Internal Med, Seoul, South Korea
[2] Yonsei Univ, Grad Sch, Dept Biostat & Comp, Seoul, South Korea
[3] Ilsan Hosp, Natl Hlth Insurance Serv, Dept Internal Med, Goyangshi, Gyeonggi Do, South Korea
[4] Yonsei Univ, Coll Med, Dept Prevent Med, Seoul, South Korea
关键词
UREA REDUCTION RATIO; ARTIFICIAL-INTELLIGENCE; FLOW-RATE; HEMODIALYSIS; PRESCRIPTION;
D O I
10.1038/s41598-021-94964-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Dialysis adequacy is an important survival indicator in patients with chronic hemodialysis. However, there are inconveniences and disadvantages to measuring dialysis adequacy by blood samples. This study used machine learning models to predict dialysis adequacy in chronic hemodialysis patients using repeatedly measured data during hemodialysis. This study included 1333 hemodialysis sessions corresponding to the monthly examination dates of 61 patients. Patient demographics and clinical parameters were continuously measured from the hemodialysis machine; 240 measurements were collected from each hemodialysis session. Machine learning models (random forest and extreme gradient boosting [XGBoost]) and deep learning models (convolutional neural network and gated recurrent unit) were compared with multivariable linear regression models. The mean absolute percentage error (MAPE), root mean square error (RMSE), and Spearman's rank correlation coefficient (Corr) for each model using fivefold cross-validation were calculated as performance measurements. The XGBoost model had the best performance among all methods (MAPE=2.500; RMSE=2.906; Corr=0.873). The deep learning models with convolutional neural network (MAPE=2.835; RMSE=3.125; Corr=0.833) and gated recurrent unit (MAPE=2.974; RMSE=3.230; Corr=0.824) had similar performances. The linear regression models had the lowest performance (MAPE=3.284; RMSE=3.586; Corr=0.770) compared with other models. Machine learning methods can accurately infer hemodialysis adequacy using continuously measured data from hemodialysis machines.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Machine Learning-Assisted Simulations and Predictions for Battery Interfaces
    Sun, Zhaojun
    Li, Xin
    Wu, Yiming
    Gu, Qilin
    Zheng, Shiyou
    ADVANCED INTELLIGENT SYSTEMS, 2025,
  • [22] Explainable machine learning predictions to support personalized cardiology strategies
    Loh, De Rong
    Yeo, Si Yong
    Tan, Ru San
    Gao, Fei
    Koh, Angela S.
    EUROPEAN HEART JOURNAL - DIGITAL HEALTH, 2022, 3 (01): : 49 - 55
  • [23] Predictions of bitcoin prices through machine learning based frameworks
    Cocco L.
    Tonelli R.
    Marchesi M.
    PeerJ Computer Science, 2021, 7 : 1 - 23
  • [24] Dialysis Adequacy: A Cross-Sectional Study to Assess the Reliability of the Online Clearance Monitor to Measure Dialysis Dose
    Rajagopalan, Arul
    Raja, Niranjan
    Mohan, Gandhi
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)
  • [25] ADEQUACY OF CAPD - A COMPARISON WITH OTHER DIALYSIS MODALITIES
    RONCO, C
    BOSCH, JP
    LEW, SQ
    FERIANI, M
    CHIARAMONTE, S
    CONZ, P
    BRENDOLAN, A
    LAGRECA, G
    NIEREN-UND HOCHDRUCKKRANKHEITEN, 1994, 23 : S110 - S115
  • [26] UV-LEDs for Monitoring Dialysis Adequacy
    Rovati, Luigi
    Cattini, Stefano
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (05) : 1720 - 1726
  • [27] Monitoring dialysis adequacy: history and current practice
    Ding, Linda
    Johnston, James
    Pinsk, Maury N.
    PEDIATRIC NEPHROLOGY, 2021, 36 (08) : 2265 - 2277
  • [28] Dialysis adequacy and nutritional status of hemodialysis patients
    Nunes, Fernanda Teixeira
    de Campos, Gianine
    Xavier de Paula, Sandra M.
    Leandro Merhi, Vania A.
    Portero-Mclellan, Katia C.
    Da Motta, Denise G.
    de Oliveira, Maria R. M.
    HEMODIALYSIS INTERNATIONAL, 2008, 12 (01) : 45 - 51
  • [29] The effect of needle gauge on recirculation and dialysis adequacy
    Gallego, E
    Portoles, JM
    Llamas, F
    Serrano, A
    Tallon, S
    Andres, E
    Gomez, C
    Olivas, E
    Tarraga, LS
    NEFROLOGIA, 1997, 17 (04): : 322 - 328
  • [30] Clinical guideline on adequacy and prescription of peritoneal dialysis
    Borras Sans, Merce
    Ponz Clemente, Esther
    Rodriguez Carmona, Ana
    Vera Rivera, Manel
    Perez Fontan, Miguel
    Rodriguez-Navarro, Carlos Quereda
    Bajo Rubio, M. Auxiliadora
    de la Espada Pina, Veronica
    Moreiras Plaza, Mercedes
    Perez Contreras, Javier
    Peso Gilsanz, Gloria del
    Prieto Velasco, Mario
    Quiros Ganga, Pedro
    Remon Rodriguez, Cesar
    Sanchez Alvarez, Emilio
    Vega Rodriguez, Nicanor
    Areste Fosalba, Nuria
    Benito, Yolanda
    Fernandez Reyes, M. Jose
    Garcia Martinez, Isabel
    Minguela Pesquera, Jose Ignacio
    Rivera Gorrin, Maite
    Uson Nuno, Ana
    NEFROLOGIA, 2024, 44 : 1 - 29