Dialysis adequacy predictions using a machine learning method

被引:17
作者
Kim, Hyung Woo [1 ]
Heo, Seok-Jae [2 ]
Kim, Jae Young [1 ,3 ]
Kim, Annie [2 ]
Nam, Chung-Mo [2 ,4 ]
Kim, Beom Seok [1 ]
机构
[1] Yonsei Univ, Coll Med, Dept Internal Med, Seoul, South Korea
[2] Yonsei Univ, Grad Sch, Dept Biostat & Comp, Seoul, South Korea
[3] Ilsan Hosp, Natl Hlth Insurance Serv, Dept Internal Med, Goyangshi, Gyeonggi Do, South Korea
[4] Yonsei Univ, Coll Med, Dept Prevent Med, Seoul, South Korea
关键词
UREA REDUCTION RATIO; ARTIFICIAL-INTELLIGENCE; FLOW-RATE; HEMODIALYSIS; PRESCRIPTION;
D O I
10.1038/s41598-021-94964-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Dialysis adequacy is an important survival indicator in patients with chronic hemodialysis. However, there are inconveniences and disadvantages to measuring dialysis adequacy by blood samples. This study used machine learning models to predict dialysis adequacy in chronic hemodialysis patients using repeatedly measured data during hemodialysis. This study included 1333 hemodialysis sessions corresponding to the monthly examination dates of 61 patients. Patient demographics and clinical parameters were continuously measured from the hemodialysis machine; 240 measurements were collected from each hemodialysis session. Machine learning models (random forest and extreme gradient boosting [XGBoost]) and deep learning models (convolutional neural network and gated recurrent unit) were compared with multivariable linear regression models. The mean absolute percentage error (MAPE), root mean square error (RMSE), and Spearman's rank correlation coefficient (Corr) for each model using fivefold cross-validation were calculated as performance measurements. The XGBoost model had the best performance among all methods (MAPE=2.500; RMSE=2.906; Corr=0.873). The deep learning models with convolutional neural network (MAPE=2.835; RMSE=3.125; Corr=0.833) and gated recurrent unit (MAPE=2.974; RMSE=3.230; Corr=0.824) had similar performances. The linear regression models had the lowest performance (MAPE=3.284; RMSE=3.586; Corr=0.770) compared with other models. Machine learning methods can accurately infer hemodialysis adequacy using continuously measured data from hemodialysis machines.
引用
收藏
页数:7
相关论文
共 28 条
[21]   Artificial intelligence outperforms experienced nephrologists to assess dry weight in pediatric patients on chronic hemodialysis [J].
Niel, Olivier ;
Bastard, Paul ;
Boussard, Charlotte ;
Hogan, Julien ;
Kwon, Theresa ;
Deschenes, Georges .
PEDIATRIC NEPHROLOGY, 2018, 33 (10) :1799-1803
[22]   Increasing dialysate flow rate increases dialyzer urea mass transfer-area coefficients during clinical use [J].
Ouseph, R ;
Ward, RA .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2001, 37 (02) :316-320
[23]   THE UREA REDUCTION RATIO AND SERUM-ALBUMIN CONCENTRATION AS PREDICTORS OF MORTALITY IN PATIENTS UNDERGOING HEMODIALYSIS [J].
OWEN, WF ;
LEW, NL ;
LIU, Y ;
LOWRIE, EG ;
LAZARUS, JM .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (14) :1001-1006
[24]   Intraoperative Arterial Pressure Variability and Postoperative Acute Kidney Injury [J].
Park, Sehoon ;
Lee, Hyung-Chul ;
Jung, Chul-Woo ;
Choi, Yunhee ;
Yoon, Hyung Jin ;
Kim, Sejoong ;
Chin, Ho Jun ;
Kim, Myoungsuk ;
Kim, Yong Chul ;
Kim, Dong Ki ;
Joo, Kwon Wook ;
Kim, Yon Su ;
Lee, Hajeong .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2020, 15 (01) :35-46
[25]   The eICU Collaborative Research Database, a freely available multi-center database for critical care research [J].
Pollard, Tom J. ;
Johnson, Alistair E. W. ;
Raffa, Jesse D. ;
Celi, Leo A. ;
Mark, Roger G. ;
Badawi, Omar .
SCIENTIFIC DATA, 2018, 5
[26]   ACCURACY OF THE UREA REDUCTION RATIO IN PREDICTING DIALYSIS DELIVERY [J].
SHERMAN, RA ;
CODY, RP ;
ROGERS, ME ;
SOLANCHICK, JC .
KIDNEY INTERNATIONAL, 1995, 47 (01) :319-321
[27]   A clinically applicable approach to continuous prediction of future acute kidney injury [J].
Tomasev, Nenad ;
Glorot, Xavier ;
Rae, Jack W. ;
Zielinski, Michal ;
Askham, Harry ;
Saraiva, Andre ;
Mottram, Anne ;
Meyer, Clemens ;
Ravuri, Suman ;
Protsyuk, Ivan ;
Connell, Alistair ;
Hughes, Cian O. ;
Karthikesalingam, Alan ;
Cornebise, Julien ;
Montgomery, Hugh ;
Rees, Geraint ;
Laing, Chris ;
Baker, Clifton R. ;
Peterson, Kelly ;
Reeves, Ruth ;
Hassabis, Demis ;
King, Dominic ;
Suleyman, Mustafa ;
Back, Trevor ;
Nielson, Christopher ;
Ledsam, Joseph R. ;
Mohamed, Shakir .
NATURE, 2019, 572 (7767) :116-+
[28]   Dialysis dose (Kt/V) and clearance variation sensitivity using measurement of ultraviolet-absorbance (on-line), blood urea, dialysate urea and ionic dialysance [J].
Uhlin, Fredrik ;
Fridolin, Ivo ;
Magnusson, Martin ;
Lindberg, Lars-Goran .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2006, 21 (08) :2225-2231