Bowel Preparations Administered the Morning of Colonoscopy Provide Similar Efficacy to a Split Dose Regimen A Meta Analysis

被引:37
作者
Avalos, Danny J. [1 ]
Castro, Fernando J. [2 ]
Zuckerman, Marc J. [1 ]
Keihanian, Tara [5 ]
Berry, Andrew C. [3 ]
Nutter, Benjamin [4 ]
Sussman, Daniel A. [6 ]
机构
[1] Texas Tech Univ Hlth Sci Ctr, Div Gastroenterol, El Paso, TX USA
[2] Cleveland Clin Florida, Dept Gastroenterol, Weston, FL USA
[3] Univ S Alabama, Dept Internal Med, Mobile, AL USA
[4] Cleveland Clin Fdn, Dept Quantitat Hlth Sci, 9500 Euclid Ave, Cleveland, OH 44195 USA
[5] Univ Miami, Jackson Mem Hosp, Dept Internal Med, Miami, FL 33136 USA
[6] Univ Miami, Jackson Mem Hosp, Dept Gastroenterol, Miami, FL 33136 USA
关键词
bowel preparation; same-day bowel preparation; morning bowel preparation; split-dose bowel preparation; colonoscopy; colorectal cancer; L POLYETHYLENE-GLYCOL; AFTERNOON COLONOSCOPY; COLORECTAL-CANCER; CLEANSING REGIMENS; REPORTED BARRIERS; CONTROLLED-TRIALS; RANDOMIZED-TRIAL; PLUS BISACODYL; VOLUME; QUALITY;
D O I
10.1097/MCG.0000000000000866
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Comparative efficacy of same-day bowel preparations for colonoscopy remains unclear. Aims: A meta-analysis of randomized controlled trials comparing the efficacy of same-day versus split dose bowel preparations for colonoscopy. Methods: A systematic search was conducted in MEDLINE, clinicaltrials.gov, Cochrane Registry, EMBASE, SCOPUS, Web of Science and CINAHL. Studies were gathered using keywords: "morning preparation", "morning bowel preparation", "same day bowel preparation", and "colonoscopy." Pooled estimates of bowel preparation quality were analyzed among studies with categorical and continuous outcomes according to relative risk (RR) or mean difference (MD). A random effects model was chosen a priori for all analyses. Results: A total of 1216 studies were retrieved with 15 trials meeting inclusion criteria. The categorical outcome of high quality bowel preparation for any same-day bowel preparation versus any split preparation was no different with a RR 0.95 [0.90;1.00] (P = 0.62). Adenoma detection rate (ADR) was not different between groups, RR 0.97 [0.79;1.20] (P = 0.81). Willingness to repeat and tolerability did not differ (RR 1.14 [0.96,1.36] (P = 0.14) and RR 1.00 [0.96;1.04] (P = 0.98), respectively. Adverse events were similar except for bloating, which was less frequent among the same-day preparation group, RR 0.68 [0.40;0.94] (P = 0.02). Conclusion: No clinically significant differences were noted among recipients of same day or split dose regimens. Adenoma detection rate, willingness to repeat and tolerability were similar, but bloating and interference with sleep favored the same-day preparations. Given lack of clinical differences, patient preference should dictate timing of colonoscopy preparation.
引用
收藏
页码:859 / 868
页数:10
相关论文
共 39 条
[21]   A randomized, endoscopist-blinded, prospective trial to compare the preference and efficacy of four bowel-cleansing regimens for colonoscopy [J].
Kim, Eun Sun ;
Lee, Woo Jin ;
Jeen, Yoon Tae ;
Choi, Hyuk Soon ;
Keum, Bora ;
Seo, Yeon Seok ;
Chun, Hoon Jai ;
Lee, Hong Sik ;
Um, Soon Ho ;
Kim, Chang Duck ;
Ryu, Ho Sang .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2014, 49 (07) :871-877
[22]   How to predict adequate bowel preparation before colonoscopy using conventional polyethylene glycol: Prospective observational study based on survey [J].
Kim, Hyun Gun ;
Jeon, Seong Ran ;
Kim, Mi Young ;
Lee, Tae Hee ;
Cho, Jun-Hyung ;
Ko, Bong Min ;
Kim, Jin-Oh ;
Cho, Joo Young ;
Lee, Joon Seong .
DIGESTIVE ENDOSCOPY, 2015, 27 (01) :87-94
[23]   Morning- only Polyethylene Glycol Is Noninferior but Less Preferred by Hospitalized Patients as Compared With Split- dose Bowel Preparation [J].
Kotwal, Vikram S. ;
Attar, Bashar M. ;
Carballo, Mauricio D. ;
Lee, Salina S. ;
Kaura, Tarun ;
Go, Benjamin ;
Zhang, Huiyuan ;
Trick, William E. .
JOURNAL OF CLINICAL GASTROENTEROLOGY, 2014, 48 (05) :414-418
[24]  
Law Wai-Lun, 2004, Asian J Surg, V27, P120, DOI 10.1016/S1015-9584(09)60324-9
[25]   Same-day Bowel Cleansing Regimen is Superior to a Split-dose Regimen Over Two Days for Afternoon Colonoscopy Results From a Large Prospective Series [J].
Longcroft-Wheaton, Gaius ;
Bhandari, Pradeep .
JOURNAL OF CLINICAL GASTROENTEROLOGY, 2012, 46 (01) :57-61
[26]   Split-Dose Preparations Are Superior to Day-Before Bowel Cleansing Regimens: A Meta-analysis [J].
Martel, Myriam ;
Barkun, Alan N. ;
Menard, Charles ;
Restellini, Sophie ;
Kherad, Omar ;
Vanasse, Alain .
GASTROENTEROLOGY, 2015, 149 (01) :79-88
[27]   Efficacy of Morning-Only Compared With Split-Dose Polyethylene Glycol Electrolyte Solution for Afternoon Colonoscopy: A Randomized Controlled Single-Blind Study [J].
Matro, Rebecca ;
Shnitser, Anastasia ;
Spodik, Maya ;
Daskalakis, Constantine ;
Katz, Leo ;
Murtha, Alexandra ;
Kastenberg, David .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2010, 105 (09) :1954-1961
[28]   Patients' experiences and reported barriers to colonoscopy in the screening context-A systematic review of the literature [J].
McLachlan, Sue-Anne ;
Clements, Alison ;
Austoker, Joan .
PATIENT EDUCATION AND COUNSELING, 2012, 86 (02) :137-146
[29]   Low-residue versus clear liquid diet before colonoscopy: a meta-analysis of randomized, controlled trials [J].
Nguyen, Douglas L. ;
Jamal, M. Mazen ;
Nguyen, Emily T. ;
Puli, Srinivas R. ;
Bechtold, Matthew L. .
GASTROINTESTINAL ENDOSCOPY, 2016, 83 (03) :499-U283
[30]   Efficacy and Tolerability of Split-Dose Magnesium Citrate: Low-Volume (2 Liters) Polyethylene Glycol vs. Single- or Split-Dose Polyethylene Glycol Bowel Preparation for Morning Colonoscopy [J].
Park, Sin Sil ;
Sinn, Dong Hyun ;
Kim, Young-Ho ;
Lim, Yeun Jung ;
Sun, Yang ;
Lee, Jun Haeng ;
Kim, Jin Yong ;
Chang, Dong Kyung ;
Son, Hee Jung ;
Rhee, Poong-Lyul ;
Rhee, Jong Chul ;
Kim, Jae J. .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2010, 105 (06) :1319-1326