Graphene-Oxide-Coated Long-Period Grating-Based Fiber Optic Sensor for Relative Humidity and External Refractive Index

被引:67
|
作者
Dissanayake, Kasun Prabuddha Wasantha [1 ]
Wu, Weiping [1 ]
Hien Nguyen [1 ]
Sun, Tong [1 ]
Grattan, Kenneth T. V. [2 ,3 ]
机构
[1] City Univ London, Sch Math Comp Sci & Engn, London EC1V 0HB, England
[2] City Univ London, Sch Math Comp Sci & Engn, London EC1V 0HB, England
[3] City Univ London, City Grad Sch, London EC1V 0HB, England
关键词
Graphene oxide; humidity sensor; long period grating; optical fibre; refractive index sensor; MOISTURE;
D O I
10.1109/JLT.2017.2756097
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Graphene oxide is a very attractive material for refractive index and humidity sensing due to its unique 2-D structure, which results in faster response times and improved sensitivity over alternative materials. In this paper, response of a graphene-oxide-coated long-period grating-based sensor to changes in relative humidity (RH) and external refractive index (as well as temperature to provide a correction for any changes) is reported. In fabricating the probes, an improved Hummer's method was used to synthesize the graphene oxide dispersion used as its basis, allowing coating of a functionalized long-period grating by using a dip-coating technique. A consistent and stable response of the resonance band intensity of the graphene-oxide-coated long-period grating was observed to the change in humidity, achieving a sensitivity of 0.15 dB/% RH with a linear correlation coefficient of 0.980 over the RH range from 60% RH to 95% RH, at room temperature (25 degrees C). A blue shift of the resonance band wavelength was recorded when the sensor was exposed to vary temperature conditions from 25 degrees C to 70 degrees C and the response was found to be linear, with a correlation coefficient of 0.997. When evaluating its performance as an external refractive index sensor, sensitivities of similar to 17 dB/RIU in the lower refractive index region (1.33-1.38) and similar to 55 dB/RIU over the higher refractive index region (1.40-1.45) were achieved. The graphene-oxide-coated long-period grating sensor probe performed well, showing a good stability and repeatability over a number of test cycles in the performance evaluation carried out.
引用
收藏
页码:1145 / 1151
页数:7
相关论文
共 50 条
  • [1] Analysis of Polyimide-Coated Optical Fiber Long-Period Grating-Based Relative Humidity Sensor
    Alwis, Lourdes
    Sun, Tong
    Grattan, Kenneth V.
    IEEE SENSORS JOURNAL, 2013, 13 (02) : 767 - 771
  • [2] Various characteristics of long-period fiber grating-based refractive index sensor
    Singh, Amit
    OPTIK, 2015, 126 (24): : 5439 - 5443
  • [3] An Ultrasensitive Long-Period Fiber Grating-Based Refractive Index Sensor with Long Wavelengths
    Li, Qiu-Shun
    Zhang, Xu-Lin
    Shi, Jian-Guo
    Xiang, Dong
    Zheng, Lan
    Yang, Yan
    Yang, Jun-Hui
    Feng, Dong
    Dong, Wen-Fei
    SENSORS, 2016, 16 (12):
  • [4] Refractive Index Sensor Based on Graphene Oxide-Coated Long-Period Fiber Grating Inscribed in a Two-Mode Fiber
    Dong, Jie
    Sang, Mei
    Wang, Shuang
    Xu, Tianhua
    Yang, Lei
    Han, Yingdong
    Zhao, Fan
    Liu, Tiegen
    IEEE ACCESS, 2020, 8 (08): : 109028 - 109037
  • [5] Optimization of long-period grating-based refractive index sensor by bent-fiber interference
    Zhang, Xinpu
    Xie, Lingxiao
    Zhang, Yang
    Peng, Wei
    APPLIED OPTICS, 2015, 54 (31) : 9152 - 9156
  • [6] Graphene oxide coated long period grating based fibre optic humidity sensor
    Dissanayake, Kasun P. W.
    Wu, Weiping
    Nguyen, Hien
    Sun, Tong
    Grattan, Kenneth T. V.
    2017 25TH INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS (OFS), 2017, 10323
  • [7] Superimposed long period fiber grating-based refractive index sensor
    Garg, Ruchi
    Thyagarajan, K.
    JOURNAL OF MODERN OPTICS, 2012, 59 (21) : 1856 - 1862
  • [8] Fiber optic relative humidity sensor based on the tilted fiber Bragg grating coated with graphene oxide
    Wang, Youqing
    Shen, Changyu
    Lou, Weimin
    Shentu, Fengying
    Zhong, Chuan
    Dong, Xinyong
    Tong, Limin
    APPLIED PHYSICS LETTERS, 2016, 109 (03)
  • [9] Application of Graphene Oxide-Based, Long-Period Fiber Grating for Sensing Relative Humidity
    Tsai, Yao-Tung
    Wu, Chao-Wei
    Tsai, Liren
    Chiang, Chia-Chin
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2021, 39 (12) : 4124 - 4130
  • [10] Characteristics of coated long-period fiber grating sensor under refractive index modulation
    Gu Zhengtian
    Zhao Xiaoyun
    Deng Chuanlu
    ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS, 2007, : 3002 - 3005