Matched Loading for Calibration of Passive Matrix Millimeter Wave Imaging System

被引:9
|
作者
Liu, Hao [1 ]
Yin, Xinyu [1 ]
Li, Hao [1 ]
Qiu, Jinghui [1 ]
Chu, Hongjun [1 ]
Denisov, Alexander [1 ]
机构
[1] Harbin Inst Technol, Dept Microwave Engn, Harbin, Heilongjiang, Peoples R China
来源
PROCEEDINGS OF THE SEVENTH INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS AND REMOTE SENSING (ICTRS 2018) | 2018年
关键词
Microwave radiometer; calibration; temperature; matched loading;
D O I
10.1145/3278161.3278169
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Passive microwave imaging system are widely designed for the remote sensing, radio-astronomical observation and especially for the detection of weapons and contraband concealed on persons under clothing in the special control devices for public security. This system must have various special calibration at the used temperatures. There described in technical details simple square matched loading for the calibration matrix radiometric 8 mm receiving array which has VSWR not pure than 1,10.
引用
收藏
页码:45 / 47
页数:3
相关论文
共 50 条
  • [1] Calibration of Visibility Samples for Real-Time Passive Millimeter Wave Imaging
    Zhao, Yan
    Hu, Anyong
    Si, Weikang
    Guo, Xiangzhou
    Miao, Jungang
    IEEE ACCESS, 2021, 9 : 106441 - 106450
  • [2] A Real-time Calibration Method of Visibility Function for Passive Millimeter Wave Imaging
    Zhao, Yan
    Si, Weikang
    Hu, Anyong
    Miao, Jungang
    2020 INTERNATIONAL CONFERENCE ON MICROWAVE AND MILLIMETER WAVE TECHNOLOGY (ICMMT 2020 ONLINE), 2020,
  • [3] Study on multichannel passive millimeter-wave radiometer imaging and superresolution
    Yan Luxin
    Zhang Tianxu
    Sheng, Zhong
    Huang, Jian
    Zhang Jianmao
    INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 2006, 27 (10): : 1403 - 1414
  • [4] STUDY ON MULTICHANNEL PASSIVE MILLIMETER-WAVE RADIOMETER IMAGING AND SUPERRESOLUTION
    Luxin Yan
    Tianxu Zhang
    Sheng Zhong
    Jian Huang
    Jianmao Zhang
    International Journal of Infrared and Millimeter Waves, 2006, 27 : 1403 - 1414
  • [5] Calibration of a collinear backscattering Mueller matrix imaging system
    Zhou, Xinrong
    Fu, Yao
    Liao, Helin
    Chen, Zhenhua
    Ji, Yanhong
    Tang, Zhilie
    FRONTIERS IN PHYSICS, 2023, 10
  • [6] Calibration of a Two-Port Millimeter-wave Quasioptical Measurement System
    Masyukov, Maxim
    Tamminen, Aleksi
    Nefedova, Irma
    Ala-Laurinaho, Juha
    Palli, Samu-Ville
    Generalov, Andrey
    Taylor, Zachary
    2024 49TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES, IRMMW-THZ 2024, 2024,
  • [7] A Deep Learning Approach for Microwave and Millimeter-Wave Radiometer Calibration
    Ogut, Mehmet
    Bosch-Lluis, Xavier
    Reising, Steven C.
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2019, 57 (08): : 5344 - 5355
  • [8] A K-Band Backscatter Fiducial for Continuous Calibration in Coherent Millimeter-Wave Imaging
    Sharma, Apoorva
    Pedross-Engel, Andreas
    Arnitz, Daniel
    Watts, Claire M.
    Smith, David R.
    Reynolds, Matthew S.
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2018, 66 (01) : 431 - 438
  • [9] A practical millimeter-wave radar calibration target
    Ruoskanen, J
    Eskelinen, P
    Heikkila, H
    Kuosmanen, P
    Kiuru, T
    IEEE ANTENNAS AND PROPAGATION MAGAZINE, 2004, 46 (02) : 94 - 97
  • [10] Simplest Passive Millimeter Wave Discriminator for the Finding of Objects
    Liu, Hao
    Qiu, Jinghui
    Yin, Xinyu
    Denisov, Alexander
    TERAHERTZ, RF, MILLIMETER, AND SUBMILLIMETER-WAVE TECHNOLOGY AND APPLICATIONS X, 2017, 10103