Application of Contrast-Enhanced Sonography With Time-Intensity Curve Analysis to Explore Hypervascularity in Achilles Tendinopathy by Using a Rabbit Model

被引:1
|
作者
Chang, Ke-Vin [1 ]
Wu, Chueh-Hung [2 ]
Ding, Yu-Hui [1 ]
Shen, Hsiu-Yu [1 ]
Wang, Tyng-Guey [1 ]
Chen, Wen-Shiang [1 ,1 ]
机构
[1] Natl Taiwan Univ, Coll Med, Taipei 10764, Taiwan
[2] Natl Taiwan Univ Hosp, Dept Phys Med & Rehabil, Yun Lin Branch, Touliu, Taiwan
关键词
Achilles tendon; contrast agent; sonography; sport; tendinopathy; ROTATOR CUFF; BLOOD-FLOW; DOPPLER; TENDON; QUANTIFICATION; TENDINOSIS; ARTIFACTS; INJECTION;
D O I
10.7863/jum.2012.31.5.737
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-The purpose of this study was to investigate the ability of contrast, enhanced sonography in staging and grading hypervascularity in tendinopathic tissues by using a rabbit model. Methods-Fourteen rabbits were injected with 100 and 50 mu L of collagenase in their left and right Achilles tendons, respectively. The vascularity was assessed by non contrast-enhanced and contrast-enhanced power Doppler sonography on day 0 (baseline) and days 1, 7, and 14 after collagenase injections. Color pixels within targeted areas were plotted according to time and analyzed by a curve-fitting method. Results-Non contrast-enhanced power Doppler sonography failed to differentiate vascularity at various stages or between bilateral tendons, whereas contrast-enhanced sonography showed that the peak color pixel amount reached its maximum on day 1 and declined over time in tendons treated with 100 mu L of collagenase. A similar trend was observed in tendons receiving 50 mu L of collagenase. For comparisons between bilateral tendons, higher vascularity was detected in those treated with more collagenase on day 1 or 7. Time-intensity curve analysis revealed rapid microbubble replenishment in both tendons during their initial phase after collagenase injections. Conclusions-Contrast-enhanced sonography discriminated the vascularity of various injury grades at different time points after collagenase injections. Time-intensity curve analysis detailed the hemodynamics in tendinopathic tissues, which helped differentiate vascularity in acute inflammatory from later degenerative phases.
引用
收藏
页码:737 / 746
页数:10
相关论文
共 50 条
  • [1] Contrast-enhanced ultrasound using a time-intensity curve for the diagnosis of renal cell carcinoma
    Aoki, Shigeyuki
    Hattori, Ryohei
    Yamamoto, Tokunori
    Funahashi, Yasuhito
    Matsukawa, Yoshihisa
    Gotoh, Momokazu
    Yamada, Yoshiaki
    Honda, Nobuaki
    BJU INTERNATIONAL, 2011, 108 (03) : 349 - 354
  • [2] Value of time-intensity curve analysis of contrast-enhanced ultrasound in the differential diagnosis of thyroid nodules
    Gu, Fen
    Han, Lu
    Yang, Xiao
    Liu, Haijing
    Li, Xiaoyu
    Guo, Kai
    Zhao, Zhen
    Zhou, Xiaodong
    Luo, Wen
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 105 : 182 - 187
  • [3] USEFULNESS OF CONTRAST-ENHANCED ULTRASOUND USING A TIME-INTENSITY CURVE FOR THE DIAGNOSIS OF CYSTIC RENAL CELL CARCINOMA
    Aoki, Shigeyuki
    Nishikawa, Genya
    Yoshizawa, Takahiko
    Kato, Yoshiharu
    Zennami, Kenji
    Tobiume, Motoi
    Nakamura, Kogenta
    Yamada, Yoshiaki
    Honda, Nobuaki
    Yamamoto, Tokunori
    Hattori, Rhohei
    Gotoh, Momokazu
    JOURNAL OF UROLOGY, 2011, 185 (04): : E926 - E926
  • [4] Role of contrast-enhanced ultrasound with time-intensity curve analysis for differentiating hypovascular solid pancreatic lesions
    Wang, Lan
    Nie, Fang
    Dong, Tiantian
    Li, Ming
    Li, Yuanyuan
    Yin, Ci
    EUROPEAN RADIOLOGY, 2023, 33 (07) : 4885 - 4894
  • [5] Role of contrast-enhanced ultrasound with time-intensity curve analysis for differentiating hypovascular solid pancreatic lesions
    Lan Wang
    Fang Nie
    Tiantian Dong
    Ming Li
    Yuanyuan Li
    Ci Yin
    European Radiology, 2023, 33 : 4885 - 4894
  • [6] Factors influencing the time-intensity curve analysis of contrast-enhanced ultrasound in kidney transplanted patients: Toward a standardized contrast-enhanced ultrasound examination
    Friedl, Sarah
    Jung, Ernst Michael
    Bergler, Tobias
    Tews, Hauke C.
    Banas, Miriam C.
    Banas, Bernhard
    Putz, Franz Josef
    FRONTIERS IN MEDICINE, 2022, 9
  • [7] Contrast-enhanced harmonic endoscopic ultrasound using time-intensity curve analysis predicts pathological grade of pancreatic neuroendocrine neoplasm
    Takada, Saimon
    Kato, Hironari
    Saragai, Yosuke
    Muro, Shinichiro
    Uchida, Daisuke
    Tomoda, Takeshi
    Matsumoto, Kazuyuki
    Horiguchi, Shigeru
    Tanaka, Noriyuki
    Okada, Hiroyuki
    JOURNAL OF MEDICAL ULTRASONICS, 2019, 46 (04) : 449 - 458
  • [8] CONTRAST ENHANCED ULTRASOUND USING A TIME-INTENSITY CURVE FOR DIAGNOSIS OF RENAL MASSES
    Aoki, Shigeyuki
    Yamamoto, Tokunori
    Funahashi, Yasuhito
    Hattori, Ryohei
    Gotoh, Momokazu
    JOURNAL OF UROLOGY, 2009, 181 (04): : 250 - 251
  • [9] Contrast-enhanced harmonic endoscopic ultrasonography with time-intensity curve analysis for intraductal papillary mucinous neoplasms of the pancreas
    Yamamoto, Naoki
    Kato, Hironari
    Tomoda, Takeshi
    Matsumoto, Kazuyuki
    Sakakihara, Ichiro
    Noma, Yasuhiro
    Horiguchi, Shigeru
    Harada, Ryo
    Tsutsumi, Koichiro
    Hori, Keisuke
    Tanaka, Takehiro
    Okada, Hiroyuki
    de Yamamoto, Kazuh
    ENDOSCOPY, 2016, 48 (01) : 26 - 34
  • [10] Noninvasive diagnosis of compensated cirrhosis using an analysis of the time-intensity curve portal vein slope gradient on contrast-enhanced ultrasonography
    Goto, Yuichi
    Okuda, Koji
    Akasu, Gen
    Kinoshita, Hisafumi
    Tanaka, Hiroyuki
    SURGERY TODAY, 2014, 44 (08) : 1496 - 1505