Segmentation of Coronary Angiograms Using Gabor Filters and Boltzmann Univariate Marginal Distribution Algorithm

被引:7
作者
Cervantes-Sanchez, Fernando [1 ]
Cruz-Aceves, Ivan [2 ]
Hernandez-Aguirre, Arturo [1 ]
Gabriel Avina-Cervantes, Juan [3 ]
Solorio-Meza, Sergio [4 ]
Ornelas-Rodriguez, Manuel [5 ]
Torres-Cisneros, Andmiguel [3 ]
机构
[1] Ctr Invest Matemat CIMAT, AC, Jalisco S-N, Guanajuato 36000, GTO, Mexico
[2] Ctr Invest Matemat CIMAT, CONACYT, AC, Jalisco S-N, Guanajuato 36000, GTO, Mexico
[3] Univ Guanajuato, DICIS, Comunidad Palo Blanco S-N, Salamanca 36885, GTO, Mexico
[4] UMAE 1 Bajio, IMSS, Unidad Invest, Leon, GTO, Mexico
[5] Tecnol Nacl Mexico Inst Tecnol Leon, Av Tecnol S-N, Leon 37290, GTO, Mexico
关键词
BLOOD-VESSELS; ARTERY TREE; ENHANCEMENT; EXTRACTION;
D O I
10.1155/2016/2420962
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
This paper presents a novel method for improving the training step of the single-scale Gabor filters by using the Boltzmann univariate marginal distribution algorithm (BUMDA) in X-ray angiograms. Since the single-scale Gabor filters (SSG) are governed by three parameters, the optimal selection of the SSG parameters is highly desirable in order to maximize the detection performance of coronary arteries while reducing the computational time. To obtain the best set of parameters for the SSG, the area (A(z)) under the receiver operating characteristic curve is used as fitness function. Moreover, to classify vessel and nonvessel pixels from the Gabor filter response, the interclass variance thresholding method has been adopted. The experimental results using the proposed method obtained the highest detection rate with A(z) = 0.9502 over a training set of 40 images and A(z) = 0.9583 with a test set of 40 images. In addition, the experimental results of vessel segmentation provided an accuracy of 0.944 with the test set of angiograms.
引用
收藏
页数:9
相关论文
共 25 条
[21]   HISTOGRAM CONCAVITY ANALYSIS AS AN AID IN THRESHOLD SELECTION [J].
ROSENFELD, A ;
DELATORRE, P .
IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS, 1983, 13 (02) :231-235
[22]   Unsupervised Segmentation of Retinal Blood Vessels using a Single Parameter Vesselness Measure [J].
Salem, Nancy M. ;
Nandi, Asoke K. .
SIXTH INDIAN CONFERENCE ON COMPUTER VISION, GRAPHICS & IMAGE PROCESSING ICVGIP 2008, 2008, :528-534
[23]  
Sang N, 2004, LECT NOTES COMPUT SC, V3314, P570
[24]  
Shan Wang, 2012, 2012 International Conference on Biomedical Engineering and Biotechnology (iCBEB), P678, DOI 10.1109/iCBEB.2012.39
[25]   Morphological enhancement of vascular angiogram with multiscale detected by Gabor filters [J].
Sun, K. Q. ;
Sang, N. .
ELECTRONICS LETTERS, 2008, 44 (02) :86-87