Effect of thermal shock due to rapid cooling on residual mechanical properties of fiber concrete exposed to high temperatures

被引:144
作者
Peng, Gai-Fei [1 ]
Bian, Song-Hua [1 ]
Guo, Zhan-Qi [2 ]
Zhao, Jie [1 ]
Peng, Xin-Lai [1 ]
Jiang, Yu-Chuang [1 ]
机构
[1] Beijing JiaoTong Univ, Fac Civil Engn & Architecture, Beijing 100044, Peoples R China
[2] Delft Univ Technol, Fac Civil Engn & Geosci, NL-2628 CN Delft, Netherlands
基金
中国国家自然科学基金;
关键词
high temperature; thermal shock; mechanical properties; fiber reinforcement; high-performance concrete; fire; rapid cooling;
D O I
10.1016/j.conbuildmat.2006.12.002
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An experimental investigation was conducted on the effect of thermal shock during cooling on residual mechanical properties of fiber concrete exposed to elevated temperatures from 200 to 800 degrees C. Various cooling regimes were used including natural cooling, spraying water for a series of durations from 5 to 60 min, and quenching in water. The temperature determination results prove that the rapid cooling regimes such as quenching in water, or water spraying for 30 min or more, caused an action of "thermal shock" to concrete under elevated temperature, characterized by a high temperature decreasing rate ranged from 25 to 44 min/degrees C. The experimental results indicate that, compared with natural cooling, thermal shock induced by water quenching and spraying water caused more severe damage to concrete, in terms of greater losses in compressive strength, tensile splitting strength, and fracture energy. The fact that the impact of spraying water for 30 min or more on mechanical properties was almost the same as that of water quenching, indicates that spraying water for 30 min or more could cause thermal shock to a similar degree to water quenching, which is in good agreement with the results of the temperature determination. Hybrid fiber (steel fiber and polypropylene fiber) can enhance residual strength and fracture energy of concrete subjected to thermal shock induced by rapid cooling from high temperatures up to 800 degrees C to room temperature. (C) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:948 / 955
页数:8
相关论文
共 50 条
[31]   Thermal and mechanical properties of concrete and its constituents at elevated temperatures: A review [J].
Malik, Manisha ;
Bhattacharyya, S. K. ;
Barai, Sudhirkumar, V .
CONSTRUCTION AND BUILDING MATERIALS, 2021, 270
[32]   Mechanical properties of geopolymer concrete containing polyvinyl alcohol fiber exposed to high temperature [J].
Tanyildizi, Harun ;
Yonar, Yavuz .
CONSTRUCTION AND BUILDING MATERIALS, 2016, 126 :381-387
[33]   Mechanical Properties of Hybrid Steel-Polypropylene Fiber Reinforced High Strength Concrete Exposed to Various Temperatures [J].
Tawfik, Maged ;
El-said, Amr ;
Deifalla, Ahmed ;
Awad, Ahmed .
FIBERS, 2022, 10 (06)
[34]   Mechanical properties and pore structure of basalt-polypropylene fiber fly ash concrete exposed to high temperatures [J].
Zheng, Qianqian ;
Zhang, Jingshuang .
AIP ADVANCES, 2022, 12 (08)
[35]   Effect of thermal damage on mineralogical and strength properties of basic volcanic rocks exposed to high temperatures [J].
Ersoy, Hakan ;
Kolayli, Hasan ;
Karahan, Murat ;
Karahan, Hilal Harputlu ;
Sunnetci, Muhammed Oguz .
BULLETIN OF ENGINEERING GEOLOGY AND THE ENVIRONMENT, 2019, 78 (03) :1515-1525
[36]   An experimental study on the residual mechanical properties of fiber reinforced concrete with high temperature and load [J].
Kim, Young-sun ;
Lee, Tae-gyu ;
Kim, Gyu-yong .
MATERIALS AND STRUCTURES, 2013, 46 (04) :607-620
[37]   Evolution of mechanical and physical properties of a lining concrete exposed to high temperatures and different relative humidities [J].
Abdo, Sh. ;
Phung, Q. T. ;
Caspeele, R. ;
Seetharam, S. C. ;
Wan-Wendner, R. .
CONSTRUCTION AND BUILDING MATERIALS, 2025, 476
[38]   Residual strength and microstructure of fiber reinforced self-compacting concrete exposed to high temperatures [J].
Sadrmomtazi, Ali ;
Gashti, Saeed Haghighat ;
Tahmouresi, Behzad .
CONSTRUCTION AND BUILDING MATERIALS, 2020, 230
[39]   Experimental study on residual mechanical properties of steel-PVA hybrid fiber high performance concrete after high temperature [J].
Xu, Qiqi ;
Jiang, Xuepeng ;
Zhang, Zhiyun ;
Xu, Chengxiang ;
Zhang, Jicheng ;
Zhou, Bowen ;
Hang, Wenjie ;
Zheng, Zezhong .
CONSTRUCTION AND BUILDING MATERIALS, 2025, 458
[40]   Effect of amorphous metallic fiber on mechanical properties of high-strength concrete exposed to high-temperature [J].
Choe, Gyeongcheol ;
Kim, Gyuyong ;
Kim, Hongseop ;
Hwang, Euichul ;
Lee, Sangkyu ;
Nam, Jeongsoo .
CONSTRUCTION AND BUILDING MATERIALS, 2019, 218 :448-456