Effect of thermal shock due to rapid cooling on residual mechanical properties of fiber concrete exposed to high temperatures

被引:144
作者
Peng, Gai-Fei [1 ]
Bian, Song-Hua [1 ]
Guo, Zhan-Qi [2 ]
Zhao, Jie [1 ]
Peng, Xin-Lai [1 ]
Jiang, Yu-Chuang [1 ]
机构
[1] Beijing JiaoTong Univ, Fac Civil Engn & Architecture, Beijing 100044, Peoples R China
[2] Delft Univ Technol, Fac Civil Engn & Geosci, NL-2628 CN Delft, Netherlands
基金
中国国家自然科学基金;
关键词
high temperature; thermal shock; mechanical properties; fiber reinforcement; high-performance concrete; fire; rapid cooling;
D O I
10.1016/j.conbuildmat.2006.12.002
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An experimental investigation was conducted on the effect of thermal shock during cooling on residual mechanical properties of fiber concrete exposed to elevated temperatures from 200 to 800 degrees C. Various cooling regimes were used including natural cooling, spraying water for a series of durations from 5 to 60 min, and quenching in water. The temperature determination results prove that the rapid cooling regimes such as quenching in water, or water spraying for 30 min or more, caused an action of "thermal shock" to concrete under elevated temperature, characterized by a high temperature decreasing rate ranged from 25 to 44 min/degrees C. The experimental results indicate that, compared with natural cooling, thermal shock induced by water quenching and spraying water caused more severe damage to concrete, in terms of greater losses in compressive strength, tensile splitting strength, and fracture energy. The fact that the impact of spraying water for 30 min or more on mechanical properties was almost the same as that of water quenching, indicates that spraying water for 30 min or more could cause thermal shock to a similar degree to water quenching, which is in good agreement with the results of the temperature determination. Hybrid fiber (steel fiber and polypropylene fiber) can enhance residual strength and fracture energy of concrete subjected to thermal shock induced by rapid cooling from high temperatures up to 800 degrees C to room temperature. (C) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:948 / 955
页数:8
相关论文
共 22 条
[1]  
[Anonymous], 1996, 5934 NISTIR BUILD FI
[2]  
[Anonymous], 2003, CHINA NEWS WEEK 1117
[3]  
[Anonymous], 2004, CEMENT CONCRETE RES, DOI DOI 10.1016/j.cemconres.2003.11.010
[4]   The effect of exposure to elevated temperatures on the fracture energy of plain concrete [J].
Baker, G .
MATERIALS AND STRUCTURES, 1996, 29 (190) :383-388
[5]  
Bentz DP, 2000, ACI MATER J, V97, P351
[6]  
Chan SYN, 1999, ACI MATER J, V96, P405
[7]   Residual strength and pore structure of high-strength concrete and normal strength concrete after exposure to high temperatures [J].
Chan, YN ;
Peng, GF ;
Anson, M .
CEMENT & CONCRETE COMPOSITES, 1999, 21 (01) :23-27
[8]  
Chen JQ., 2004, FIRE SCI TECHNOL, V23, P99
[9]  
*CHIN STAND, 1999, 176711999 GBT CHIN S, P1
[10]   Crack propagation behavior of cermets and cemented carbides under repeated thermal shocks by the improved quench test [J].
Ishihara, S ;
Goshima, T ;
Nomura, K ;
Yoshimoto, T .
JOURNAL OF MATERIALS SCIENCE, 1999, 34 (03) :629-636