MR imaging and MR arthrography of the postoperative shoulder: Spectrum of normal and abnormal findings

被引:53
作者
Mohana-Borges, AVR [1 ]
Chung, CB [1 ]
Resnick, D [1 ]
机构
[1] Vet Adm Med Ctr, Dept Radiol, La Jolla, CA 92161 USA
关键词
magnetic resonance (MR); arthrography; shoulder; injuries; MR; surgery;
D O I
10.1148/rg.241035081
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The postoperative shoulder may be evaluated with various imaging modalities, including radiography, ultrasonography, computed tomography, and magnetic resonance (MR) imaging, each of which has advantages and disadvantages. For optimal soft-tissue visualization, MR imaging and MR arthrography are widely used. Several factors, however, may decrease the accuracy of MR imaging in the evaluation of the postoperative shoulder. These factors include surgical distortions of native anatomy, changes in the signal intensity of tissues, and image degradation caused by metallic artifacts. To maximize the accuracy of MR imaging, the radiologist must select the most appropriate pulse sequences and techniques for the given anatomic structure and the suspected postoperative condition. To avoid magnetic susceptibility artifacts at MR imaging, inversion recovery may be used instead of fat saturation and fast spin-echo sequences may be used instead of conventional spin-echo sequences or gradient-echo sequences. MR arthrography is most useful for optimal delineation of the rotator cuff, capsulolabral structures, and tendon defects. To achieve accurate image interpretation the radiologist must be familiar with the arthroscopic and the open surgical techniques currently used to repair internal derangements of the glenohumeral joint, as well as with the typical imaging findings in each postoperative situation. ((C))RSNA, 2004.
引用
收藏
页码:69 / 85
页数:17
相关论文
共 26 条
[1]   Long-term results of the Latarjet procedure for the treatment of anterior instability of the shoulder [J].
Allain, J ;
Goutallier, D ;
Glorion, C .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (06) :841-852
[2]  
Arroyo JS, 1999, DISORDERS SHOULDER D, P31
[3]   MR arthrography of the shoulder: Variants and pitfalls - Response [J].
Beltran, J .
RADIOGRAPHICS, 1997, 17 (06) :1414-1415
[4]   MR arthrography of the glenohumeral joint: Two concentrations of gadoteridol versus Ringer solution as the intraarticular contrast material [J].
Binkert, CA ;
Zanetti, M ;
Gerber, C ;
Hodler, J .
RADIOLOGY, 2001, 220 (01) :219-224
[5]   MR arthrography of the glenohumeral joint: A tailored approach [J].
Chung, CB ;
Dwek, JR ;
Feng, S ;
Resnick, D .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (01) :217-219
[6]   Comparison of clinical and patient-based measures to assess medium-term outcomes following shoulder surgery for disorders of the rotator cuff [J].
Dawson, J ;
Hill, G ;
Fitzpatrick, R ;
Carr, A .
ARTHRITIS & RHEUMATISM-ARTHRITIS CARE & RESEARCH, 2002, 47 (05) :513-519
[7]   Prospective longitudinal analysis of postoperative shoulder function - A ten-year follow-up study of full-thickness rotator cuff tears [J].
Galatz, LM ;
Griggs, S ;
Cameron, BD ;
Iannotti, JP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (07) :1052-1056
[8]   Metallic artefacts in MR imaging: Effects of main field orientation and strength [J].
Guermazi, A ;
Miaux, Y ;
Zaim, S ;
Peterfy, CG ;
White, D ;
Genant, HK .
CLINICAL RADIOLOGY, 2003, 58 (04) :322-328
[9]   The changes occurring after the Putti-Platt procedure using magnetic resonance imaging [J].
Hashiuchi, T ;
Ozaki, J ;
Sakurai, G ;
Imada, E .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2000, 120 (5-6) :286-289
[10]  
Haygood T M, 1993, Magn Reson Imaging Clin N Am, V1, P143