Radiation Protection in Pediatric Radiology

被引:97
作者
Alzen, Gerhard [1 ]
Benz-Bohm, Gabriele [2 ]
机构
[1] Univ Giessen, Abt Kinderradiol, Med Zentrum Radiol, D-35385 Giessen, Germany
[2] Univ Cologne, Radiol Inst & Poliklin, Funkt Bereich Kinderradiol, D-5000 Cologne 41, Germany
来源
DEUTSCHES ARZTEBLATT INTERNATIONAL | 2011年 / 108卷 / 24期
关键词
X-RAY-EXAMINATION; DOSE REDUCTION; CANCER RISKS; CT; EXPOSURE; CHILDREN; RECONSTRUCTION; PERFORMANCE; CRITERIA; QUALITY;
D O I
10.3238/arztebl.2011.0407
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The German Federal Law on Radiation Control contains no special provisions for X-ray studies in children and adolescents, even though exposure to ionizing radiation must be kept especially low in young persons, because their tissues are highly radiosensitive. Children, who have many years left to live, are more likely than adults to develop radiation-induced cancer; also, as future parents, they are at risk for passing on radiation-induced genetic defects to the next generation. Whenever possible, radiological studies on children and adolescents should be of a type that does not involve ionizing radiation, such as ultrasonography or magnetic resonance imaging. Pediatric conventional X-rays and computerized tomography (CT) require special examining techniques and protocols that are adapted to the patient's age and to the indication for the study. Methods: We selectively review the literature on pediatric dose reduction and discuss our own investigations on the subject as well. Results: The essential technical prerequisites for lowering the dose of ionizing radiation in conventional X-ray studies include the proper setting of tube voltage, the use of tube filters, suitable patient positioning and fixation, variable use of a scattered-radiation grid, and a modern storage-plate system. In CT studies, the use of age-and indication-adapted protocols can lower radiation exposure by as much as 95%. Conclusion: There are now many ways to lower the exposure of children and adolescents to ionizing radiation without sacrificing diagnostic reliability. The main factors in lowering exposure are proper attention to clinical indications, the use of special X-ray protocols, the use of alternative imaging studies without ionizing radiation wherever possible, and the expertise of the examiner.
引用
收藏
页码:407 / U1502
页数:10
相关论文
共 39 条
[1]  
ALZEN G, 2007, FORTSCHR RONTGENS S1, V179, P115
[2]  
BEIDERWELLEN KJ, 2010, THESIS JLU GIESSEN
[3]   Risk of cancer from diagnostic X-rays:: estimates for the UK and 14 other countries [J].
Berrington de González, A ;
Darby, S .
LANCET, 2004, 363 (9406) :345-351
[4]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[5]   Estimating cancer risks from pediatric CT: going from the qualitative to the quantitative [J].
Brenner, DJ .
PEDIATRIC RADIOLOGY, 2002, 32 (04) :228-231
[6]   Estimated radiation risks potentially associated with full-body CT screening [J].
Brenner, DJ ;
Elliston, CD .
RADIOLOGY, 2004, 232 (03) :735-738
[7]  
Brix G, 2005, RADIOLOGE, V45, P340, DOI 10.1007/s00117-005-1184-3
[8]  
*BUND STRAHL, 2003, BEK DIAGN REF RAD NU
[9]  
*BUND STRAHL, GRENZW DOS STRAHL
[10]  
*BUND UMW NAT REAK, 2003, RONTG, P604