Temperature distribution in deep tissue phantom during laser irradiation at 1,064 nm measured by thermocouples and thermal imaging technique

被引:8
作者
Cho, Jiyong [2 ]
Byun, Hyuk [3 ]
Lee, Seungdeok [3 ]
Kim, Jung Kyung [1 ]
机构
[1] Kookmin Univ, Sch Mech Engn, Seoul 136702, South Korea
[2] Kookmin Univ, Grad Sch, Dept Mech Engn, Seoul 136702, South Korea
[3] Dongguk Univ, Dept Oriental Med, Grad Sch, Seoul 100715, South Korea
基金
新加坡国家研究基金会;
关键词
Moxibustion; Infrared laser; Laser irradiation; Tissue phantom; Agar gel; Sample holder; Temperature distribution; HEAT;
D O I
10.1007/s12650-011-0074-1
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Moxibustion generates heat stimulation which expands blood vessels and promotes blood circulation. Furthermore, moxibustion provokes the release of diffuse noxious inhibitory controls (DNIC) to treat and prevent diseases. However, inherent drawbacks, such as pain, burn scars, smoke and bad smells, limit its use. A novel noncontact-type laser therapy device having effect similar to that of commercial moxibustion is being developed using a 1,064-nm infrared (IR) diode-pumped solid state (DPSS) laser. The therapy device allows direct interaction of laser light with the skin rendering temperature distribution both on the skin surface and deep under the skin. We devised a sample holder containing a tissue phantom to measure the three-dimensional temperature distribution with thermocouples inserted deep inside the phantom. Agar gel of 2.5% concentration was used as the tissue phantom in our experiments. Our results revealed that the maximum temperature occurred far below the surface of the tissue phantom, which was heated by laser irradiation at 1,064 nm. This occurrence was also confirmed by a thermal imaging method. In contrast, temperature gradually decreased through the depth of the tissue phantom heated with commercial moxibustion. Simple analytical models were constructed to explain the underlying heat-transfer mechanisms involved in moxibustion and laser irradiation.
引用
收藏
页码:265 / 272
页数:8
相关论文
共 13 条
[1]   SUCCESSFUL USE OF A PHYSIOLOGICALLY ACCEPTABLE ARTIFICIAL SKIN IN THE TREATMENT OF EXTENSIVE BURN INJURY [J].
BURKE, JF ;
YANNAS, IV ;
QUINBY, WC ;
BONDOC, CC ;
JUNG, WK .
ANNALS OF SURGERY, 1981, 194 (04) :413-428
[2]  
Carslaw H.S., 1986, Conduction of Heat In Solids, V2nde
[3]  
CHO J, 2010, P 14 INT S FLOW VIS
[4]  
Dong-Eop Yoon, 2006, Transactions of the Korean Institute of Electrical Engineers, D, V55, P386
[5]   Temperature measurement on tissue surface during laser irradiation [J].
Gnyawali, Surya C. ;
Chen, Yicho ;
Wu, Feng ;
Bartels, Kenneth E. ;
Wicksted, James P. ;
Liu, Hong ;
Sen, Chandan K. ;
Chen, Wei R. .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2008, 46 (02) :159-168
[6]   Measurement of temperature-dependent specific heat of biological tissues [J].
Haemmerich, D ;
Schutt, DJ ;
dos Santos, I ;
Webster, JG ;
Mahvi, DM .
PHYSIOLOGICAL MEASUREMENT, 2005, 26 (01) :59-67
[7]   Heat-transfer analysis of indirect moxibustion using unsteady conjugate heat-transfer solutions [J].
Jeon, Byoung Jin ;
Choi, Hyoung Gwon .
JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2010, 24 (10) :2051-2057
[8]  
차지영, 2009, [System and Control, 전자공학회논문지 - SC], V46, P50
[9]  
JUNG B, 2006, P OPT SOC KOR ANN M, P361
[10]   DIFFUSE NOXIOUS INHIBITORY CONTROLS (DNIC) .1. EFFECTS ON DORSAL HORN CONVERGENT NEURONS IN THE RAT [J].
LEBARS, D ;
DICKENSON, AH ;
BESSON, JM .
PAIN, 1979, 6 (03) :283-304