A Novel Alignment Procedure and Results for the LHCb Silicon Tracker Detector

被引:0
作者
Dupertuis, Frederic [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Lab Phys Hautes Energies, CH-1015 Lausanne, Switzerland
来源
2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2011年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The LHCb experiment is designed to perform high-precision measurements of CP-violation and rare decays of B hadrons at the Large Hadron Collider. The Silicon Tracker (ST) is a silicon strip detector intended to precisely measure the particle trajectories produced by proton-proton interactions. It has a total sensitive area of about 12 m(2) around the beam axis. The Silicon Tracker has a single hit resolution better than 60 mu m that put strict constrains on its alignment. The current alignment procedure is demonstrated to be fast, robust and able to achieve a suitable alignment precision. Two novelties have been added to the method to improve significantly the alignment accuracy using tracks from vertex-and mass-constrained resonances and as well as track extrapolation with magnet off data. Selected results demonstrating alignment improvements are presented.
引用
收藏
页码:1314 / 1318
页数:5
相关论文
共 6 条