THE ULTRASONIC MEASUREMENT OF CRYSTALLOGRAPHIC ORIENTATION FOR IMAGING ANISOTROPIC COMPONENTS WITH 2D ARRAYS

被引:3
作者
Lane, C. J. L. [1 ,2 ]
Dunhill, A. K. [1 ]
Drinkwater, B. W. [2 ]
Wilcox, P. D. [2 ]
机构
[1] Rolls Royce PLC, GP 4-1-4, Bristol BS34 7QE, Avon, England
[2] Univ Bristol, Dept Mech Engn, Bristol BS8 1TR, Avon, England
来源
REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 30A AND 30B | 2011年 / 1335卷
基金
英国工程与自然科学研究理事会;
关键词
Ultrasonic Arrays; Elastic Anisotropy; Single Crystals; APERTURE FOCUSING TECHNIQUE; FULL-MATRIX;
D O I
10.1063/1.3591930
中图分类号
O59 [应用物理学];
学科分类号
摘要
Single crystal components are used widely in the gas-turbine industry. However, these components are elastically anisotropic which causes difficulties when performing NDE inspections with ultrasound. Recently an ultrasonic algorithm for a 2D array has been corrected to perform the reliable volumetric inspection of single crystals. For the algorithm to be implemented the crystallographic orientation of the components must be known. This paper, therefore, develops and reviews crystallographic orientation methods using 2D ultrasonic arrays. The methods under examination are based on the anisotropic propagation of surface and bulk waves and an image-based orientation method is also considered.
引用
收藏
页码:803 / 810
页数:8
相关论文
共 9 条
  • [1] Engstrand CR, 2008, MATER EVAL, V66, P407
  • [2] Post-processing of the full matrix of ultrasonic transmit-receive array data for non-destructive evaluation
    Holmes, C
    Drinkwater, BW
    Wilcox, PD
    [J]. NDT & E INTERNATIONAL, 2005, 38 (08) : 701 - 711
  • [3] The Wavenumber Algorithm for Full-Matrix Imaging Using an Ultrasonic Array
    Hunter, Alan J.
    Drinkwater, Bruce W.
    Wilcox, Paul D.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2008, 55 (11) : 2450 - 2462
  • [4] THE ROLLS-ROYCE SCORPIO SYSTEM
    JONES, AT
    BAXTER, C
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 1995, 6 (01) : 131 - 133
  • [5] INSPECTION OF SINGLE CRYSTAL AEROSPACE COMPONENTS WITH ULTRASONIC ARRAYS
    Lane, C. J. L.
    Dunhill, A.
    Drinkwater, B. W.
    Wilcox, P. D.
    [J]. REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 29A AND 29B, 2010, 1211 : 2060 - +
  • [6] Lane C. J. L., IEEE T ULTR IN PRESS
  • [7] CUDA-based GPU computing for fast tomography visualisations
    Saxena, N.
    Baheti, G. L.
    Tripathi, D. K.
    Songara, K. C.
    Meghwal, L. R.
    Meena, V. L.
    [J]. INSIGHT, 2010, 52 (05) : 262 - 264
  • [8] An implementation of synthetic aperture focusing technique in frequency domain
    Stepinski, Tadeusz
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (07) : 1399 - 1408
  • [9] An analytical comparison of ultrasonic array imaging algorithms
    Velichko, Alexander
    Wilcox, Paul D.
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2010, 127 (04) : 2377 - 2384