Alternate Electrode Positions for the Measurement of Hand Volumes Using Bioimpedance Spectroscopy

被引:1
作者
Edwick, Dale O. [1 ,2 ,3 ]
Hince, Dana A. [4 ]
Rawlins, Jeremy M. [1 ,5 ]
Wood, Fiona M. [1 ,3 ,6 ]
Edgar, Dale W. [1 ,3 ,4 ]
机构
[1] Fiona Stanley Hosp, State Adult Burns Unit, CD15,102-118 Murdoch Dr, Murdoch, WA 6150, Australia
[2] Univ Notre Dame Australia, Sch Physiotherapy, Fremantle, WA, Australia
[3] Fiona Stanley Hosp, Fiona Wood Fdn, Murdoch, WA, Australia
[4] Univ Notre Dame Australia, Inst Hlth Res, Fremantle, WA, Australia
[5] Royal Perth Hosp, Dept Plast & Maxillofacial Surg, Perth, WA, Australia
[6] Univ Western Australia, Burn Injury Res Unit, Nedlands, WA, Australia
关键词
bioelectrical impedance analysis; electrode sites; body composition; body fluid distribution; wounds; hand volume; BIOELECTRICAL-IMPEDANCE ANALYSIS; CONCURRENT VALIDITY; EDEMA; LYMPHEDEMA; WATER; BODY; RELIABILITY; FREQUENCY; AGREEMENT; SITES;
D O I
10.1089/lrb.2019.0078
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Bioimpedance spectroscopy (BIS) is a tool that can be used to measure body composition in a variety of populations. Previous studies have investigated novel applications to utilize BIS to measure localized body composition, including in the hand. According to BIS guidelines, there should be no skin wounds at the site of electrodes, and that electrode positions may be modified in specific circumstances, as our group has validated previously in burn wound populations. Methods and Results: To determine in noninjured participants, whether BIS measurements recorded using alternate electrode positions on the palm of the hand and forearm, or a combination of electrodes on the dorsum and volar surface of the hand and forearm, were comparable with electrode positions on the dorsum of the hand and forearm. The study demonstrated that drive and sense electrodes on the palm of the hand and volar forearm, and a combination of electrodes on the palm of the hand and dorsum of the forearm, resulted in comparable measures of impedance of extracellular water (difference from reference position: 1.26%-4.75%, p = 0.411-0.558) and total water (difference from reference: 2.15%-2.40%, p = 0.258-0.781). Electrodes on the dorsum of the hand and volar forearm resulted in significantly different measures for the same BIS variables (percentage difference range 4.66%-6.15%, p < 0.001-0.003). Conclusion: Electrode positions on the palm of the hand and volar forearm, or on the palm of the hand and dorsum of the forearm, are interchangeable as clinical measures of hand lymphedema and total water impedance.
引用
收藏
页码:560 / 571
页数:12
相关论文
共 50 条
  • [21] Effect of regional muscle damage and inflammation following eccentric exercise on electrical resistance and the body composition assessment using bioimpedance spectroscopy
    Shiose, Keisuke
    Tanabe, Yoko
    Ohnishi, Takahiro
    Takahashi, Hideyuki
    [J]. JOURNAL OF PHYSIOLOGICAL SCIENCES, 2019, 69 (06) : 895 - 901
  • [22] Comparison of bioimpedance spectroscopy and X-Ray micro-computed tomography for total fat volume measurement in mice
    Aubertin, Gaelle
    Sayeh, Amira
    Dillenseger, Jean-Philippe
    Ayme-Dietrich, Estelle
    Choquet, Philippe
    Niederhoffer, Nathalie
    [J]. PLOS ONE, 2017, 12 (08):
  • [23] Segmental measurement of breast cancer-related arm lymphoedema using perometry and bioimpedance spectroscopy
    Czerniec, Sharon A.
    Ward, Leigh C.
    Lee, Mi-Joung
    Refshauge, Kathryn M.
    Beith, Jane
    Kilbreath, Sharon L.
    [J]. SUPPORTIVE CARE IN CANCER, 2011, 19 (05) : 703 - 710
  • [24] A Practical Method to Reduce Electrode Mismatch Artefacts during 4-electrode BioImpedance Spectroscopy Measurements
    Montalibet, A.
    McAdams, E.
    [J]. 2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 5775 - 5779
  • [25] Resistivity coefficients for body composition analysis using bioimpedance spectroscopy: effects of body dominance and mixture theory algorithm
    Ward, L. C.
    Isenring, E.
    Dyer, J. M.
    Kagawa, M.
    Essex, T.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2015, 36 (07) : 1529 - 1549
  • [26] Influence of electrode mismatch on Cole parameter estimation from Total Right Side Electrical Bioimpedance Spectroscopy measurements
    Buendia, Ruben
    Bogonez-Franco, Paco
    Nescolarde, Lexa
    Seoane, Fernando
    [J]. MEDICAL ENGINEERING & PHYSICS, 2012, 34 (07) : 1024 - 1028
  • [27] Skin-Electrode Contact Area in Electrical Bioimpedance Spectroscopy. Influence in Total Body Composition Assessment
    Marquez, J. C.
    Seoane, F.
    Lindecrantz, K.
    [J]. 2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 1867 - 1870
  • [28] Measurement of Fluid Status Using Bioimpedance Methods in Korean Pediatric Patients on Hemodialysis
    Yang, Eun Mi
    Park, Eujin
    Ahn, Yo Han
    Choi, Hyun Jin
    Kang, Hee Gyung
    Cheong, Hae Il
    Ha, Il Soo
    [J]. JOURNAL OF KOREAN MEDICAL SCIENCE, 2017, 32 (11) : 1828 - 1834
  • [29] Fluid balance assessment in pediatric hemodialysis patients by using whole-body bioimpedance spectroscopy ( WB-BIS)
    Khin, Ei E.
    Elmaghrabi, Ayah Y.
    Alvarado, Luis A.
    Modem, Vinai
    Quigley, Raymond
    [J]. PEDIATRIC NEPHROLOGY, 2022, 37 (10) : 2449 - 2456
  • [30] Clinical Utility of Fluid Volume Assessment in Heart Failure Patients Using Bioimpedance Spectroscopy
    Accardi, Andrew J.
    Matsubara, Bradley S.
    Gaw, Richelle L.
    Daleiden-Burns, Anne
    Heywood, James Thomas
    [J]. FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8