Extra- vs. intramedullary treatment of pertrochanteric fractures: a biomechanical in vitro study comparing dynamic hip screw and intramedullary nail

被引:38
作者
Weiser, Lukas [1 ]
Ruppel, Andreas A. [2 ]
Nuechtern, Jakob V. [1 ]
Sellenschloh, Kay [3 ]
Zeichen, Johannes [2 ]
Pueschel, Klaus [4 ]
Morlock, Michael M. [3 ]
Lehmann, Wolfgang [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Trauma Hand & Reconstruct Surg, D-20246 Hamburg, Germany
[2] Johannes Wesling Klinikum Minden, Trauma & Orthoped Dept, Minden, Germany
[3] TUHH Hamburg Univ Technol, Inst Biomech, Hamburg, Germany
[4] Univ Med Ctr Hamburg Eppendorf, Inst Forens Med, D-20246 Hamburg, Germany
关键词
Pertrochanteric fracture; Hip fracture; Sliding hip screw; Dynamic hip screw; Intramedullary nail; Intertan nail; PROXIMAL FEMORAL NAIL; INTERTROCHANTERIC FRACTURES; GAMMA-NAIL; FIXATION; ANTIROTATION; METAANALYSIS; INTERTAN; FAILURE; FORCES; FEMUR;
D O I
10.1007/s00402-015-2252-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Due to the demographic trend, pertrochanteric fractures of the femur will gain increasing importance in the future. Both extra- and intramedullary implants are used with good results in the treatment of these fractures. New, angular stable extramedullary implants promise increased postoperative stability even with unstable fractures. Additional trochanteric plates are intended to prevent secondary impaction, varisation and shortening of the fracture, as well as medialisation of the femoral shaft. The aim of this study was to perform a biomechanical comparison of both procedures regarding their postoperative stability and failure mechanisms. Twelve fresh-frozen human femurs were randomized into two groups based on the volumetric bone mineral density (vBMD). Standardized pertrochanteric fractures (AO31-A2.3) were generated and treated either with an angular stable dynamic hip screw (DHS) or an intramedullary nail (nail). Correct implant position and the tip-apex distance (TAD) were controlled postoperatively using X-ray. Specimens were mounted in a servohydraulic testing machine and an axial loading was applied according to a single-leg stance model. Both groups were biomechanically compared with regard to native and postoperative stiffness, survival during cyclic testing, load to failure, and failure mechanisms. TAD, vBMD, and native stiffness were similar for both groups. The stiffness decreased significantly from native to postoperative state in all specimens (p < 0.001). The postoperative stiffness of both groups varied non-significantly (p = 0.275). The failure loads for specimens treated with the nail were significantly higher than for those treated with the DHS (8480.8 +/- A 1238.9 N vs. 2778.2 +/- A 196.8 N; p = 0.008). Extra- and intramedullary osteosynthesis showed comparable results as regards postoperative stiffness and survival during cyclic testing. Since the failure load of the nail was significantly higher in the tested AO31-A2.3 fracture model, we conclude that intramedullary implants should be preferred in these, unstable, fractures.
引用
收藏
页码:1101 / 1106
页数:6
相关论文
共 26 条
[1]   Prospective randomised controlled trial of an intramedullary nail versus a sliding hip screw for intertrochanteric fractures of the femur [J].
Aktselis, Ioannis ;
Kokoroghiannis, Constantine ;
Fragkomichalos, Evaggelos ;
Koundis, Georgios ;
Deligeorgis, Anastasios ;
Daskalakis, Emmanouil ;
Vlamis, John ;
Papaioannou, Nikolaos .
INTERNATIONAL ORTHOPAEDICS, 2014, 38 (01) :155-161
[2]   Nail or plate fixation of intertrochanteric hip fractures: Changing pattern of practice [J].
Anglen, Jeffrey O. ;
Weinstein, James N. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (04) :700-707
[3]   A Comparison of the Long Gamma Nail with the Sliding Hip Screw for the Treatment of AO/OTA 31-A2 Fractures of the Proximal Part of the Femur A Prospective Randomized Trial [J].
Barton, Tristan M. ;
Gleeson, Robert ;
Topliss, Claire ;
Greenwood, Rosemary ;
Harries, William J. ;
Chesser, Timothy J. S. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (04) :792-798
[4]   HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS [J].
BERGMANN, G ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1993, 26 (08) :969-990
[5]   Hip contact forces and gait patterns from routine activities [J].
Bergmann, G ;
Deuretzbacher, G ;
Heller, M ;
Graichen, F ;
Rohlmann, A ;
Strauss, J ;
Duda, GN .
JOURNAL OF BIOMECHANICS, 2001, 34 (07) :859-871
[6]   Cutting out in pertrochanteric fractures -: problem of osteoporosis? [J].
Bonnaire, F. ;
Weber, A. ;
Boesl, O. ;
Eckhardt, C. ;
Schwieger, K. ;
Linke, B. .
UNFALLCHIRURG, 2007, 110 (05) :425-432
[7]   Internal forces and moments in the femur during walking [J].
Duda, GN ;
Schneider, E ;
Chao, EYS .
JOURNAL OF BIOMECHANICS, 1997, 30 (09) :933-941
[8]   Cement augmentation of the proximal femoral nail antirotation for the treatment of osteoporotic pertrochanteric fractures-A biomechanical cadaver study [J].
Fensky, F. ;
Nuechtern, J. V. ;
Kolb, J. P. ;
Huber, S. ;
Rupprecht, M. ;
Jauch, S. Y. ;
Sellenschloh, K. ;
Pueschel, K. ;
Morlock, M. M. ;
Rueger, J. M. ;
Lehmann, W. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (06) :802-807
[9]  
Gotze B., 1998, Aktuelle traumatologie, V28, P197
[10]   Failure of femoral head fixation: a cadaveric analysis of lag screw cut-out with the gamma locking nail and AO dynamic hip screw [J].
Haynes, RC ;
Poll, RG ;
Miles, AW ;
Weston, RB .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1997, 28 (5-6) :337-341