Single-image phase retrieval using an edge illumination X-ray phase-contrast imaging setup

被引:34
作者
Diemoz, Paul C. [1 ,2 ]
Vittoria, Fabio A. [1 ,2 ]
Hagen, Charlotte K. [1 ]
Endrizzi, Marco [1 ]
Coan, Paola [3 ,4 ]
Brun, Emmanuel [4 ,5 ]
Wagner, Ulrich H. [6 ]
Rau, Christoph [6 ]
Robinson, Ian K. [2 ,7 ]
Bravin, Alberto [5 ]
Olivo, Alessandro [1 ,2 ]
机构
[1] UCL, Dept Biomed Engn & Med Phys, London WC1E 6BT, England
[2] Res Complex Harwell, Didcot OX11 0FA, Oxon, England
[3] Univ Munich, Inst Clin Radiol, D-81377 Munich, Germany
[4] Univ Munich, Dept Phys, D-85748 Garching, Germany
[5] European Synchrotron Radiat Facil, F-38043 Grenoble, France
[6] Diamond Light Source, Didcot OX11 0DE, Oxon, England
[7] London Ctr Nanotechnol, London WC1H 0AH, England
基金
英国工程与自然科学研究理事会;
关键词
X-ray imaging; phase-contrast imaging; phase retrieval; image formation theory; MASS-DENSITY IMAGES; SYNCHROTRON-RADIATION; TOMOGRAPHY; RESOLUTION; SYSTEMS;
D O I
10.1107/S1600577515008978
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A method is proposed which enables the retrieval of the thickness or of the projected electron density of a sample from a single input image acquired with an edge illumination phase-contrast imaging setup. The method assumes the case of a quasi-homogeneous sample, i.e. a sample with a constant ratio between the real and imaginary parts of its complex refractive index. Compared with current methods based on combining two edge illumination images acquired in different configurations of the setup, this new approach presents advantages in terms of simplicity of acquisition procedure and shorter data collection time, which are very important especially for applications such as computed tomography and dynamical imaging. Furthermore, the fact that phase information is directly extracted, instead of its derivative, can enable a simpler image interpretation and be beneficial for subsequent processing such as segmentation. The method is first theoretically derived and its conditions of applicability defined. Quantitative accuracy in the case of homogeneous objects as well as enhanced image quality for the imaging of complex biological samples are demonstrated through experiments at two synchrotron radiation facilities. The large range of applicability, the robustness against noise and the need for only one input image suggest a high potential for investigations in various research subjects.
引用
收藏
页码:1072 / 1077
页数:6
相关论文
共 34 条
  • [1] Born M., 1980, Wolf Principles of Optics, Vsixth
  • [2] X-ray phase-contrast imaging: from pre-clinical applications towards clinics
    Bravin, Alberto
    Coan, Paola
    Suortti, Pekka
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (01) : R1 - R35
  • [3] Analyser-based mammography using single-image reconstruction
    Briedis, D
    Siu, KKW
    Paganin, DM
    Pavlov, KM
    Lewis, RA
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (15) : 3599 - 3611
  • [4] Phase retrieval in X-ray phase-contrast imaging suitable for tomography
    Burvall, Anna
    Lundstrom, Ulf
    Takman, Per A. C.
    Larsson, Daniel H.
    Hertz, Hans M.
    [J]. OPTICS EXPRESS, 2011, 19 (11): : 10359 - 10376
  • [5] Diffraction enhanced x-ray imaging
    Chapman, D
    Thomlinson, W
    Johnston, RE
    Washburn, D
    Pisano, E
    Gmur, N
    Zhong, Z
    Menk, R
    Arfelli, F
    Sayers, D
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) : 2015 - 2025
  • [6] Evaluation of imaging performance of a taper optics CCD 'FReLoN' camera designed for medical imaging
    Coan, P
    Peterzol, A
    Fiedler, S
    Ponchut, C
    Labiche, JC
    Bravin, A
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2006, 13 : 260 - 270
  • [7] PHASE-CONTRAST IMAGING OF WEAKLY ABSORBING MATERIALS USING HARD X-RAYS
    DAVIS, TJ
    GAO, D
    GUREYEV, TE
    STEVENSON, AW
    WILKINS, SW
    [J]. NATURE, 1995, 373 (6515) : 595 - 598
  • [8] Dejus R. J., 1996, REV SCI INSTRUM, V67, P3356
  • [9] Sensitivity of laboratory based implementations of edge illumination X-ray phase-contrast imaging
    Diemoz, P. C.
    Hagen, C. K.
    Endrizzi, M.
    Olivo, A.
    [J]. APPLIED PHYSICS LETTERS, 2013, 103 (24)
  • [10] X-Ray Phase-Contrast Imaging with Nanoradian Angular Resolution
    Diemoz, P. C.
    Endrizzi, M.
    Zapata, C. E.
    Pesic, Z. D.
    Rau, C.
    Bravin, A.
    Robinson, I. K.
    Olivo, A.
    [J]. PHYSICAL REVIEW LETTERS, 2013, 110 (13)