Prospective self-gating for swallowing motion: A feasibility study in carotid artery wall MRI using three-dimensional variable-flip-angle turbo spin-echo

被引:14
作者
Fan, Zhaoyang [2 ,3 ]
Zuehlsdorff, Sven
Liu, Xin [4 ]
Li, Debiao [1 ,2 ,3 ]
机构
[1] Cedars Sinai Med Ctr, Biomed Imaging Res Inst, Pacific Theatres PACT, Dept Biomed Sci, Los Angeles, CA 90048 USA
[2] Univ Calif Los Angeles, Dept Bioengn, Los Angeles, CA USA
[3] Siemens Healthcare, Cardiovasc MR R&D, Chicago, IL USA
[4] Chinese Acad Sci, Paul C Lauterbur Res Ctr Biomed Imaging, Shenzhen Inst Adv Technol, Shenzhen, Peoples R China
基金
美国国家卫生研究院;
关键词
black-blood MRI; carotid artery; swallowing; self-gating; MAGNETIC-RESONANCE ANGIOGRAPHY; HEART CORONARY MRA; ATHEROSCLEROTIC PLAQUE; CINE MRI; COMPENSATION; CONTRAST; TSE;
D O I
10.1002/mrm.23295
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Three-dimensional black-blood MRI is a promising noninvasive imaging technique for the assessment of atherosclerotic carotid artery disease. However, this technique is inherently susceptible to motion. In particular, swallowing can result in considerable wall motion at the carotid bifurcations, which may induce drastic image degradation or substantial overestimation of wall thickness. Self-gating techniques have previously been shown to be capable of resolving and compensating for cardiac or respiratory motion during MRI. This work presents a self-gating-based prospective motion gating scheme that is combined with a three-dimensional variable-flip-angle turbo spin-echo sequence (SPACE) for detecting swallowing motion. Self-gating signal readouts along the superiorinferior direction during each repetition time period are used to derive the projection profiles of the imaging volume. Based on cross-correlation analysis between the projection profiles and the corresponding reference profiles, swallowing motion can be detected and the motion-contaminated data will subsequently be discarded and reacquired in the next repetition time. The self-gated SPACE sequence was validated on eight healthy volunteers and two patients and, when compared with the conventional SPACE sequence, proved to be more resistant to swallowing motion and significantly improved image quality as well as the sharpness of carotid artery wall boundaries. Magn Reson Med, 2012. (C) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:490 / 498
页数:9
相关论文
共 29 条
[1]   Pulsatile motion effects on 3D magnetic resonance angiography: Implications for evaluating carotid artery stenoses [J].
Al-Kwifi, O ;
Kim, JK ;
Stainsby, J ;
Huang, YX ;
Sussman, MS ;
Farb, RI ;
Wright, GA .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (03) :605-611
[2]   Comparison between 2D and 3D high-resolution black-blood techniques for carotid artery wall Imaging in clinically significant atherosclerosis [J].
Balu, Niranjan ;
Chu, Baocheng ;
Hatsukami, Thomas S. ;
Yuan, Chun ;
Yarnykh, Vasily L. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (04) :918-924
[3]   Swallowing, arterial pulsation, and breathing induce motion artifacts in carotid artery MRI [J].
Boussel, L ;
Herigault, G ;
de la Vega, A ;
Nonent, M ;
Douek, PC ;
Serfaty, JM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (03) :413-415
[4]   Prospective self-gating for simultaneous compensation of cardiac and respiratory motion [J].
Buehrer, Martin ;
Curcic, Jelena ;
Boesiger, Peter ;
Kozerke, Sebastian .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (03) :683-690
[5]  
CHAN CF, 2009, P 17 ANN M ISMRM HON, P1829
[6]   Novel Technique Used to Detect Swallowing in Volume-Selective Turbo Spin-Echo (TSE) for Carotid Artery Wall Imaging [J].
Chan, Cheuk F. ;
Gatehouse, Peter D. ;
Hughes, Ray ;
Roughton, Michael ;
Pennell, Dudley J. ;
Firmin, David N. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (01) :211-216
[7]   3D volume-selective turbo spin echo for carotid artery wall imaging with navigator detection of swallowing [J].
Crowe, LA ;
Keegan, J ;
Gatehouse, PD ;
Mohiaddin, RH ;
Varghese, A ;
Symmonds, K ;
Cannell, TM ;
Yang, GZ ;
Firmin, DN .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (04) :583-588
[8]   Volume-selective 3D turbo spin echo imaging for vascular wall imaging and distensibility measurement [J].
Crowe, LA ;
Gatehouse, P ;
Yang, GZ ;
Mohiaddin, RH ;
Varghese, A ;
Charrier, C ;
Keegan, J ;
Firmin, DN .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (05) :572-580
[9]   Carotid Arterial Wall MRI at 3T Using 3D Variable-Flip-Angle Turbo Spin-Echo (TSE) with Flow-Sensitive Dephasing (FSD) [J].
Fan, Zhaoyang ;
Zhang, Zhuoli ;
Chung, Yiu-Cho ;
Weale, Peter ;
Zuehlsdorff, Sven ;
Carr, James ;
Li, Debiao .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (03) :645-654
[10]   Clinical imaging of the high-risk or vulnerable atherosclerotic plaque [J].
Fayad, ZA ;
Fuster, V .
CIRCULATION RESEARCH, 2001, 89 (04) :305-316