The development and course of patch-test reactions to 2-hydroxyethyl methacrylate and ethyleneglycol dimethacrylate

被引:49
作者
Isaksson, M [1 ]
Lindberg, M
Sundberg, K
Hallander, A
Bruze, M
机构
[1] Lund Univ, Malmo Univ Hosp, Dept Occupat & Environm Dermatol, SE-20502 Malmo, Sweden
[2] Karolinska Inst, Dept Med, Stockholm, Sweden
[3] Stockholm Cty Council, Stockholm, Sweden
[4] Ryhov Hosp, Dept Dermatol, Jonkoping, Sweden
关键词
2-hydroxyethyl methacrylate; acrylates; active sensitization; contact allergy; ethyleneglycol dimethacrylate; flare-up reaction; late reactions; methacrylates; persistent patch-test reactions;
D O I
10.1111/j.0105-1873.2005.00705.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Because Methacrylic monomers are used in dental work, dental personnel, technicians, and patients are at risk of being sensitized. 2-hydroxyethyl methacrylate (2-HEMA) and ethyleneglycol dimethacrylate (EGDMA) are commonly used. Allergic test reactions to them sometimes appear beyond D7. This study was designed to study the development and course of positive test reactions to 2-HEMA and EGDMA in allergic patients as a mean to elucidate the issue of patch-test sensitization. 12 patients with contact allergy to 2-HEMA and EGDMA were retested with dilution series. The clinical course was followed for 1 month. During the study, 25 positive test reactions to 2-HEMA and 19 to EGDMA were diagnosed. Within the 1st week, 21 were noted for 2-HEMA and 18 for EGDMA. After 10 days, another 2 reactions appeared for 2-HEMA and 1 for EGDMA. All but 1 patient with the latter reactions also had positive reactions within the 1st week. After 1 month, 12 reactions for 2-HEMA and 10 for EGDMA remained. Patch-test reactions to 2-HEMA and EGDMA are long-lasting. The patch-test concentrations of 2.0% for 2-HEMA and EGDMA may be continually used. Positive test reactions emerging after 10 days do not automatically imply active sensitization.
引用
收藏
页码:292 / 297
页数:6
相关论文
共 24 条
[1]  
[Anonymous], 1980, CONTACT DERMATITIS
[2]  
Bruze M, 1995, CONTACT DERMATITIS, V33, P386
[3]   A STUDY ON EXPERT READING OF PATCH TEST REACTIONS - INTERINDIVIDUAL ACCORDANCE [J].
BRUZE, M ;
ISAKSSON, M ;
EDMAN, B ;
BJORKNER, B ;
FREGERT, S ;
MOLLER, H .
CONTACT DERMATITIS, 1995, 32 (06) :331-337
[5]  
*CHEM DIAGN, 2005, PATCH TEST PROD CAT
[6]   HAND DERMATITIS IN DENTAL-TECHNICIANS [J].
ESTLANDER, T ;
RAJANIEMI, R ;
JOLANKI, R .
CONTACT DERMATITIS, 1984, 10 (04) :201-205
[7]  
*FINN ADV BOARD CH, 1992, ACR COMP US EV HLTH
[8]  
Fisher A.A., 1986, CONTACT DERMATITIS, V3rd
[9]   ALLERGIC SENSITIZATION OF THE SKIN AND ORAL MUCOSA TO ACRYLIC DENTURE MATERIALS [J].
FISHER, AA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1954, 156 (03) :238-242
[10]  
Fregert S, 1981, MANUAL CONTACT DERMA