Use of Smartphones to Detect Diabetic Retinopathy: Scoping Review and Meta-Analysis of Diagnostic Test Accuracy Studies

被引:45
作者
Tan, Choon Han [1 ]
Kyaw, Bhone Myint [2 ]
Smith, Helen [3 ]
Tan, Colin S. [1 ,4 ]
Car, Lorainne Tudor [3 ,5 ]
机构
[1] Nanyang Technol Univ, Lee Kong Chian Sch Med, Singapore, Singapore
[2] Nanyang Technol Univ, Lee Kong Chian Sch Med, Ctr Populat Hlth Sci, Singapore, Singapore
[3] Nanyang Technol Univ, Lee Kong Chian Sch Med, Family Med & Primary Care, 11 Mandalay Rd, Singapore, Singapore
[4] Tan Tock Seng Hosp, Dept Ophthalmol, Singapore, Singapore
[5] Imperial Coll London, Sch Publ Hlth, Dept Primary Care & Publ Hlth, London, England
关键词
diabetic retinopathy; smartphone; mobile phone; ophthalmoscopy; artificial intelligence; telemedicine; FUNDUS PHOTOGRAPHY; MANAGEMENT; SPECIFICITY; SENSITIVITY; ADAPTER;
D O I
10.2196/16658
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Diabetic retinopathy (DR), a common complication of diabetes mellitus, is the leading cause of impaired vision in adults worldwide. Smartphone ophthalmoscopy involves using a smartphone camera for digital retinal imaging. Utilizing smartphones to detect DR is potentially more affordable, accessible, and easier to use than conventional methods. Objective: This study aimed to determine the diagnostic accuracy of various smartphone ophthalmoscopy approaches for detecting DR in diabetic patients. Methods: We performed an electronic search on the Medical Literature Analysis and Retrieval System Online (MEDLINE), EMBASE, and Cochrane Library for literature published from January 2000 to November 2018. We included studies involving diabetic patients, which compared the diagnostic accuracy of smartphone ophthalmoscopy for detecting DR to an accurate or commonly employed reference standard, such as indirect ophthalmoscopy, slit-lamp biomicroscopy, and tabletop fundus photography. Two reviewers independently screened studies against the inclusion criteria, extracted data, and assessed the quality of included studies using the Quality Assessment of Diagnostic Accuracy Studies-2 tool, with disagreements resolved via consensus. Sensitivity and specificity were pooled using the random effects model. A summary receiver operating characteristic (SROC) curve was constructed. This review is reported in line with the Preferred Reporting Items for a Systematic Review and Meta-analysis of Diagnostic Test Accuracy Studies guidelines. Results: In all, nine studies involving 1430 participants were included. Most studies were of high quality, except one study with limited applicability because of its reference standard The pooled sensitivity and specificity for detecting any DR was 87% (95% CI 74%-94%) and 94% (95% CI 81%-98%); mild nonproliferative DR (NPDR) was 39% (95% CI 10%-79%) and 95% (95% CI 91%-98%); moderate NPDR was 71% (95% CI 57%-81%) and 95% (95% CI 88%-98%); severe NPDR was 80% (95% CI 49%-94%) and 97% (95% CI 88%-99%); proliferative DR (PDR) was 92% (95% CI 79%-97%) and 99% (95% CI 96%-99%); diabetic macular edema was 79% (95% CI 63%-89%) and 93% (95% CI 82%-97%); and referral-warranted DR was 91% (95% CI 86%-94%) and 89% (95% CI 56%-98%). The area under SROC curve ranged from 0.879 to 0.979. The diagnostic odds ratio ranged from 11.3 to 1225. Conclusions: We found heterogeneous evidence showing that smartphone ophthalmoscopy performs well in detecting DR. The diagnostic accuracy for PDR was highest. Future studies should standardize reference criteria and classification criteria and evaluate other available forms of smartphone ophthalmoscopy in primary care settings.
引用
收藏
页数:16
相关论文
共 46 条
[21]  
KIM T, 2017, INVEST OPHTH VIS SCI, V58
[22]   A Smartphone-Based Tool for Rapid, Portable, and Automated Wide-Field Retinal Imaging [J].
Kim, Tyson N. ;
Myers, Frank ;
Reber, Clay ;
Loury, P. J. ;
Loumou, Panagiota ;
Webster, Doug ;
Echanique, Chris ;
Li, Patrick ;
Davila, Jose R. ;
Maamari, Robi N. ;
Switz, Neil A. ;
Keenan, Jeremy ;
Woodward, Maria A. ;
Paulus, Yannis M. ;
Margolis, Todd ;
Fletcher, Daniel A. .
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2018, 7 (05)
[23]   Epidemiology of diabetic retinopathy, diabetic macular edema and related vision loss [J].
Lee, Ryan ;
Wong, Tien Y. ;
Sabanayagam, Charumathi .
EYE AND VISION, 2015, 2
[24]   Scoping studies: advancing the methodology [J].
Levac, Danielle ;
Colquhoun, Heather ;
O'Brien, Kelly K. .
IMPLEMENTATION SCIENCE, 2010, 5
[25]  
Lira Rodrigo Pessoa Cavalcanti, 2007, Arq. Bras. Oftalmol., V70, P615, DOI 10.1590/S0004-27492007000400011
[26]   Optical coherence tomography: a key to the future management of patients with diabetic macular oedema [J].
Massin, Pascale ;
Girach, Aniz ;
Erginay, Ali ;
Gaudric, Alain .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2006, 84 (04) :466-474
[27]   Preferred Reporting Items for a Systematic Review and Meta-analysis of Diagnostic Test Accuracy Studies The PRISMA-DTA Statement [J].
McInnes, Matthew D. F. ;
Moher, David ;
Thombs, Brett D. ;
McGrath, Trevor A. ;
Bossuyt, Patrick M. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2018, 319 (04) :388-396
[28]  
Micheletti J Morgan, 2016, J Diabetes Sci Technol, V10, P295, DOI 10.1177/1932296816629158
[29]   Management of diabetic retinopathy - A systematic review [J].
Mohamed, Quresh ;
Gillies, Mark C. ;
Wong, Tien Y. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (08) :902-916
[30]   Fundus Photography in the 21st Century-A Review of Recent Technological Advances and Their Implications for Worldwide Healthcare [J].
Panwar, Nishtha ;
Huang, Philemon ;
Lee, Jiaying ;
Keane, Pearse A. ;
Chuan, Tjin Swee ;
Richhariya, Ashutosh ;
Teoh, Stephen ;
Lim, Tock Han ;
Agrawal, Rupesh .
TELEMEDICINE AND E-HEALTH, 2016, 22 (03) :198-208