This case series describes the implantation of multiple acrylic intraocular lenses (IOLs) in the capsular bag of six eyes of three highly hyperopic patients (spherical equivalent +5.75 to +8.62) during cataract surgery. Two foldable acrylic lenses were placed in the capsular bag of each eye. Preoperative best corrected visual acuity (BCVA) ranged from 20/50 to 20/300. Postoperative uncorrected visual acuity ranged from 20/25 to 20/60, while BCVA ranged from 20/25 to 20/40. Multiple acrylic lenses were used successfully in cases in which a single IOL would have given inadequate correction.
引用
收藏
页码:1368 / 1372
页数:5
相关论文
共 16 条
[1]   EFFECT OF INCISION LENGTH, LOCATION, AND SHAPE ON LOCAL CORNEOSCLERAL DEFORMATION DURING CATARACT-SURGERY [J].
ARMENIADES, CD ;
BORIEK, A ;
KNOLLE, GE .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (01) :83-87
[2]   IMPLANTING 2 POSTERIOR CHAMBER INTRAOCULAR LENSES IN A CASE OF MICROPHTHALMOS [J].
GAYTON, JL ;
SANDERS, VN .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (06) :776-777
[3]  
HOFFER KJ, 1994, J CATARACT REFR SURG, V20, P677
[5]   A 3-PART SYSTEM FOR REFINING INTRAOCULAR-LENS POWER CALCULATIONS [J].
HOLLADAY, JT ;
PRAGER, TC ;
CHANDLER, TY ;
MUSGROVE, KH ;
LEWIS, JW ;
RUIZ, RS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1988, 14 (01) :17-24
[6]   EVALUATION OF 35 CONSECUTIVE SI-30 PHACOFLEX LENSES WITH HIGH-REFRACTIVE SILICONE OPTIC IMPLANTED IN THE CAPSULORHEXIS BAG [J].
MENAPACE, R .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1995, 21 (03) :339-347
[7]   EVALUATION OF THE 1ST 100 CONSECUTIVE PHACOFLEX SILICONE LENSES IMPLANTED IN THE BAG THROUGH A SELF-SEALING TUNNEL INCISION USING THE PRODIGY INSERTER [J].
MENAPACE, R ;
AMON, M ;
PAPAPANOS, P ;
RADAX, U .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1994, 20 (03) :299-309
[8]   NO-STITCH, SMALL-INCISION CATARACT-SURGERY WITH FLEXIBLE INTRAOCULAR-LENS IMPLANTATION [J].
MENAPACE, R ;
RADAX, U ;
AMON, M ;
PAPAPANOS, P .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1994, 20 (05) :534-542
[9]   PHACOEMULSIFICATION, CAPSULORHEXIS, AND INTRAOCULAR-LENS POWER PREDICTION ACCURACY [J].
OLSEN, T ;
GIMBEL, H .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (06) :695-699
[10]   Two year clinical study of a soft acrylic intraocular lens [J].
Oshika, T ;
Suzuki, Y ;
Kizaki, H ;
Yaguchi, S .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (01) :104-109