Virtual commissioning of camera-based quality assurance systems for mixed model assembly lines

被引:6
作者
Piero, Nils [1 ]
Schmitt, Michael [2 ]
机构
[1] Uni Stuttgart, Grad Sch Excellence Adv Mfg Engn, D-70569 Stuttgart, Germany
[2] Fraunhofer Inst Comp Graph Res IGD, D-64283 Darmstadt, Germany
来源
27TH INTERNATIONAL CONFERENCE ON FLEXIBLE AUTOMATION AND INTELLIGENT MANUFACTURING, FAIM2017 | 2017年 / 11卷
关键词
Quality assurance; Mixed model assembly lines; Computer Vision; CAD-based; Augmeented-Reality;
D O I
10.1016/j.promfg.2017.07.195
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
We propose a new computer vision based technique that does not use data collected from real images to teach a decision-making algorithm. It uses CAD-Models which is already available from the product planning phase to check all product variants on the assembly line for misplaced or wrong components. This solution can hence be used already in the ramp-up phase of new models in which problems are more frequent. Our method can also easily adapt to changes of production, where existing methods need to redo the whole teach-in process, we just need to set the new nominal position of the part in the reference coordinate system, which can even be done semi automatically upfront the changes are initiated in the assembly line. (C) 2017 The Authors. Published by Elsevier B.V.
引用
收藏
页码:914 / 921
页数:8
相关论文
共 50 条
[11]   Balancing and Sequencing Optimization of the Mixed Model Assembly Lines [J].
Cao, Zhenxin ;
Ma, Shiping .
ISCSCT 2008: INTERNATIONAL SYMPOSIUM ON COMPUTER SCIENCE AND COMPUTATIONAL TECHNOLOGY, VOL 1, PROCEEDINGS, 2008, :732-736
[12]   Balancing and scheduling of flexible mixed model assembly lines [J].
Ozturk, Cemalettin ;
Tunali, Semra ;
Hnich, Brahim ;
Ornek, M. Arslan .
CONSTRAINTS, 2013, 18 (03) :434-469
[13]   Quality assurance procedures based on dosimetric, gamma analysis as a fast reliable tool for commissioning brachytherapy treatment planning systems [J].
Zwierzchowski, Grzegorz ;
Bieleda, Grzegorz ;
Skowronek, Janusz .
RADIOLOGY AND ONCOLOGY, 2017, 51 (04) :469-474
[14]   GEC-ESTRO guidelines for commissioning and quality assurance of TG-43 based brachytherapy treatment planning systems [J].
De Brabandere, Marisol ;
Beaulieu, Luc ;
Dejean, Catherine ;
Dempsey, Claire ;
Lee, Chris ;
Mason, Josh ;
Rivard, Mark J. ;
Perez-Calatayud, Jose ;
Smith, Ryan ;
Steenhuijsen, Jacco ;
Walter, Renate ;
Workman, Geraldine ;
Zuchora, Anysja ;
Siebert, Frank-Andre .
RADIOTHERAPY AND ONCOLOGY, 2025, 210
[15]   Infrared camera based thermometry for quality assurance of superficial hyperthermia applicators [J].
Mueller, Johannes ;
Hartmann, Josefin ;
Bert, Christoph .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (07) :2646-2664
[16]   A Coevolutionary Algorithm for Balancing and Sequencing in Mixed Model Assembly Lines [J].
Yeo Keun Kim ;
Jae Yun Kim ;
Yeongho Kim .
Applied Intelligence, 2000, 13 :247-258
[17]   Production Orders Sequencing in Mixed-Model Assembly Lines [J].
Zemczak, Marcin .
ENGINEERING SOLUTIONS AND TECHNOLOGIES IN MANUFACTURING, 2014, 657 :359-363
[18]   A coevolutionary algorithm for balancing and sequencing in mixed model assembly lines [J].
Kim, YK ;
Kim, JY ;
Kim, Y .
APPLIED INTELLIGENCE, 2000, 13 (03) :247-258
[19]   Sequencing mixed-model assembly lines: Survey, classification and model critique [J].
Boysen, Nils ;
Fliedner, Malte ;
Scholl, Armin .
EUROPEAN JOURNAL OF OPERATIONAL RESEARCH, 2009, 192 (02) :349-373
[20]   Balancing and scheduling of flexible mixed model assembly lines with parallel stations [J].
Cemalettin Öztürk ;
Semra Tunalı ;
Brahim Hnich ;
Arslan Örnek .
The International Journal of Advanced Manufacturing Technology, 2013, 67 :2577-2591