Closure of the annulus fibrosus of the intervertebral disc using a novel suture application device-in vivo porcine and ex vivo biomechanical evaluation

被引:37
作者
Bateman, Antony H. [1 ]
Balkovec, Christian [2 ]
Akens, Margarete K. [3 ,4 ,5 ]
Chan, Andrea H. W. [1 ]
Harrison, Robert D. [6 ]
Oakden, Wendy [7 ]
Yee, Albert J. M. [1 ]
McGill, Stuart M. [2 ]
机构
[1] Sunnybrook Hlth Sci Ctr, 2075 Bayview Ave,MG 371B, Toronto, ON M4N 3M5, Canada
[2] Univ Waterloo, Dept Kinesiol, 200 Univ Ave West, Waterloo, ON N2L 3G1, Canada
[3] Univ Hlth Network, Techna Inst, 100 Coll St,Rm 211, Toronto, ON M5G 1P5, Canada
[4] Univ Toronto, Dept Med Biophys, 101 Coll St, Toronto, ON M5T 1L7, Canada
[5] Univ Toronto, Dept Surg, 101 Coll St, Toronto, ON M5T 1L7, Canada
[6] Anchor Orthoped XT Inc, 2645 Matheson Blvd East, Mississauga, ON L4W 5S4, Canada
[7] Sunnybrook Res Inst, 2075 Bayview Ave, Toronto, ON M4N 3M5, Canada
关键词
Annular repair; Annulus fibrosus closure; Disc repair; Discectomy; Intervertebral disc; Minimally invasive; Porcine model; Re-herniation; Surgery; Suture application device; LUMBAR DISKECTOMY; PROSPECTIVE COHORT; CERVICAL-SPINE; HERNIATION; MODEL; OUTCOMES; REPAIR; MULTICENTER; PRESSURE; SCIATICA;
D O I
10.1016/j.spinee.2016.03.005
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Defects in the annulus fibrosus (AF) remain a challenge in the surgical treatment of lumbar disc herniations with persistent defects, allowing potential re herniation of nucleus pulposus (NP) tissue. A cervical porcine model was chosen to simulate human lumbar intervertebral disc (IVD). PURPOSE: The aim of this study was to determine the technical feasibility of closure of the AF of the IVD using a novel minimally invasive Kerrison-shaped suture application device. STUDY DESIGN: Ex vivo biomechanical and in vivo porcine device evaluations were performed. METHODS: Ex vivo biomechanical evaluation: 15 porcine spinal units were explanted and subjected to mock discectomy. The annular defect was closed using 2-0 non-absorbable (ultra-high molecular-weight polyethylene, UHMWPE) suture and Dines knot. The knot was backed up with two, three, or four throws. The spinal unit was subject to 4000 cycles of flexion/extension with 1500 N of axial load, and assessed for knot slippage. In vivo porcine device evaluation: three pigs (53-57 kg) were anesthetized and underwent a ventral surgical approach to the cervical spine. The AF of two discs was incised, and simulated partial NP discectomy was performed. The defect was closed at one level using the AnchorKnot device to apply the suture with a Dines knot and four throws. The pigs were observed for 4 weeks before euthanasia, allowing 7T magnetic resonance imaging (MRI) and histological evaluation. RESULTS: A Dines knot with four throws experienced no slippage after 4000 cycles. This configuration was tested in vivo. Clinically, the neurological examination in treated pigs was normal following surgery. Histological and MRI assessment confirmed sustained defect closure at 4 weeks. There was no reaction to the suture material and no NP extrusion at any of the sutured levels. CONCLUSIONS: This study demonstrates that it is technically feasible to perform AF defect closure in a porcine model. This novel device achieved AF defect closure that was maintained through 4 weeks in vivo. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:889 / 895
页数:7
相关论文
共 29 条
  • [1] 'Stress' distributions inside intervertebral discs - The effects of age and degeneration
    Adams, MA
    McNally, DS
    Dolan, P
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (06): : 965 - 972
  • [2] [Anonymous], ACTA ORTHOP SCA S100
  • [3] The Quebec Task Force classification for spinal disorders and the severity, treatment, and outcomes of sciatica and lumbar spinal stenosis
    Atlas, SJ
    Deyo, RA
    Patrick, DL
    Convery, K
    Keller, RB
    Singer, DE
    [J]. SPINE, 1996, 21 (24) : 2885 - 2892
  • [4] Prospective, Multicenter, Randomized, Controlled Study of Anular Repair in Lumbar Discectomy Two-Year Follow-up
    Bailey, Alexander
    Araghi, Ali
    Blumenthal, Scott
    Huffmon, George V.
    [J]. SPINE, 2013, 38 (14) : 1161 - 1169
  • [5] Two-year outcome after lumbar microdiscectomy versus microscopic sequestrectomy -: Part 2:: Radiographic evaluation and correlation with clinical outcome
    Barth, Martin
    Diepers, Michael
    Weiss, Christel
    Thome, Claudius
    [J]. SPINE, 2008, 33 (03) : 273 - 279
  • [6] Baums MH, 2013, KNEE SURG SPORT TR A, V23, P1351
  • [7] Development of poly(trimethylene carbonate) network implants for annulus fibrosus tissue engineering
    Blanquer, Sebastien B. G.
    Sharifi, Shahriar
    Grijpma, Dirk W.
    [J]. JOURNAL OF APPLIED BIOMATERIALS & FUNCTIONAL MATERIALS, 2012, 10 (03): : 177 - 184
  • [8] FATIGUE FRACTURE OF HUMAN LUMBAR VERTEBRAE
    BRINCKMANN, P
    JOHANNLEWELING, N
    HILWEG, D
    BIGGEMANN, M
    [J]. CLINICAL BIOMECHANICS, 1987, 2 (02) : 94 - 96
  • [9] CHANGE OF DISK HEIGHT, RADIAL DISK BULGE, AND INTRADISCAL PRESSURE FROM DISCECTOMY - AN INVITRO INVESTIGATION ON HUMAN LUMBAR DISKS
    BRINCKMANN, P
    GROOTENBOER, H
    [J]. SPINE, 1991, 16 (06) : 641 - 646
  • [10] Biomechanical and in vivo evaluation of experimental closure devices of the annulus fibrosus designed for a goat nucleus replacement model
    Bron, Johannes L.
    van der Veen, Albert J.
    Helder, Marco N.
    van Royen, Barend J.
    Smit, Theodoor H.
    [J]. EUROPEAN SPINE JOURNAL, 2010, 19 (08) : 1347 - 1355