Optimization of background suppression for arterial spin labeling perfusion imaging

被引:85
作者
Maleki, Nasim [1 ,2 ]
Dai, Weiying [3 ]
Alsop, David C. [3 ]
机构
[1] Childrens Hosp, Dept Radiol, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Dept Radiol, Boston, MA 02115 USA
[3] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
基金
美国国家卫生研究院;
关键词
Magnetic resonance imaging; Arterial spin labeling; Perfusion; Background suppression; INVERSION; FREQUENCY; PULSES; SIGNAL; ECHO;
D O I
10.1007/s10334-011-0286-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To present an algorithm for optimization of background suppression pulse timing for arterial spin labeling (ASL) perfusion imaging. An algorithm for optimization of background suppression pulse timing is proposed. Numerical optimization of timing of the background suppression pulses is investigated in both constrained and unconstrained ASL sequences. The performance of the parameters from the algorithm is evaluated in phantom and also in vivo in five human subjects. The background signal is suppressed to less than 1% across a broad range of T1s with a modest number of inversion pulses using the timings acquired from the numerical optimization algorithm proposed in this study. The performance of the parameters from the algorithm is also confirmed in vivo. Successful background suppression over a broad range of tissues is achievable. Values for optimal pulse timing in both pulsed and continuous ASL studies are reported to facilitate sequence design with different labeling parameters.
引用
收藏
页码:127 / 133
页数:7
相关论文
共 23 条
  • [1] Alsop D, 1999, INT SOC MAGN RES MED, P601
  • [2] Blamire AM, 2000, MAGNET RESON MED, V43, P701, DOI 10.1002/(SICI)1522-2594(200005)43:5<701::AID-MRM12>3.0.CO
  • [3] 2-Y
  • [4] Combination of signals from array coils using image-based estimation of coil sensitivity profiles
    Bydder, M
    Larkman, DJ
    Hajnal, JV
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (03) : 539 - 548
  • [5] Dai W, 2011, MAGN RESON IN PRESS
  • [6] Continuous Flow-Driven Inversion for Arterial Spin Labeling Using Pulsed Radio Frequency and Gradient Fields
    Dai, Weiying
    Garcia, Dairon
    de Bazelaire, Cedric
    Alsop, David C.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (06) : 1488 - 1497
  • [7] MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: Preliminary results
    de Bazelaire, CMJ
    Duhamel, GD
    Rofsky, NM
    Alsop, DC
    [J]. RADIOLOGY, 2004, 230 (03) : 652 - 659
  • [8] MULTIPLE INVERSION RECOVERY REDUCES STATIC TISSUE SIGNAL IN ANGIOGRAMS
    DIXON, WT
    SARDASHTI, M
    CASTILLO, M
    STOMP, GP
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) : 257 - 268
  • [9] Duhamel G., 2004, Proc. 12'th ISMRM, P518
  • [10] High-sensitivity single-shot perfusion-weighted fMRI
    Duyn, JH
    Tan, CX
    van Gelderen, P
    Yongbi, MN
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (01) : 88 - 94