A nondestructive testing technique based on magnetic flux leakage is presented to inspect automatically the stay cables with large diameters of a cable-stayed bridge. Using the proposed inspection method, an online nondestructive testing (NDT) modular sensor is developed. The wreath-like sensor is composed of several sensor units that embrace the cable at equal angles. Each sensor unit consists of two permanent magnets and a hall sensor to detect the magnetic flux density. The modular sensor can be installed conveniently on cables with various diameters by increasing the number of sensor units and adjusting the relative distances between adjacent sensor units. Results of the experiments performed on a man-made cable with faults prove that the proposed sensor can inspect the status signals Of the inner wires of the cables. To filter the interfering signals, three processing algorithms are discussed, including the moving average method, improved detrending algorithm, and signal processing based on a digital filter. Results show that the developed NDT sensor carried by a cable inspection robot can move along the cable and monitor the state of the stay cables.
引用
收藏
页码:661 / 669
页数:9
相关论文
共 25 条
[1]   A multiscale polynomial filter for adaptive smoothing [J].
Browne, M. ;
Mayer, N. ;
Cutmore, T. R. H. .
DIGITAL SIGNAL PROCESSING, 2007, 17 (01) :69-75
[2]  
Chase S.B., 1997, Public Roads, V61, P16
[3]   Automatic flaw detection in NDE signals using a panel of neural networks [J].
Christen, R. ;
Bergamini, A. .
NDT & E INTERNATIONAL, 2006, 39 (07) :547-553
[4]   Three-dimensional localization of defects in stay cables using magnetic flux leakage methods [J].
Christen, R ;
Bergamini, A ;
Motavalli, M .
JOURNAL OF NONDESTRUCTIVE EVALUATION, 2003, 22 (03) :93-101
[5]   Influence of steel wrapping on magneto-inductive testing of the main cables of suspension bridges [J].
Christen, R. ;
Bergamini, A. ;
Motavalli, M. .
NDT & E INTERNATIONAL, 2009, 42 (01) :22-27
[6]  
COOPER M, 1992, MATER EVAL, V50, P1383
[7]   Tubing thread inspection by magnetic flux leakage [J].
Ding, JF ;
Kang, YH ;
Wu, XJ .
NDT & E INTERNATIONAL, 2006, 39 (01) :53-56
[8]  
GELLER LB, 1995, MATER EVAL, V53, P1002
[9]  
Haight R.Q., 1997, Journal of Bridge Engineering, V2, P157
[10]   Development of inspection gauge system for gas pipeline [J].
Han, HS ;
Yu, JJ ;
Park, CG ;
Lee, JG .
KSME INTERNATIONAL JOURNAL, 2004, 18 (03) :370-378