Thermal performance of a window shutter containing PCM: Numerical validation and experimental analysis

被引:96
作者
Silva, Tiago [1 ]
Vicente, Romeu [1 ]
Amaral, Claudia [1 ,2 ,3 ]
Figueiredo, Antonio [1 ]
机构
[1] Univ Aveiro, Dept Civil Engn, RISCO, Campus Univ Santiago, P-3810193 Aveiro, Portugal
[2] Univ Aveiro, CICECO Aveiro Inst Mat, Aveiro, Portugal
[3] Univ Aveiro, Dept Chem, Aveiro, Portugal
关键词
Heat transfer; Phase change material (PCM); Simulation; Thermal energy storage (TES); Thermal performance; Validation; PHASE-CHANGE MATERIALS; ENERGY STORAGE TECHNOLOGIES; BUILDING APPLICATIONS; SIMULATION-MODELS; GLAZING SYSTEMS; SOLAR; WALL; CALIBRATION; COMFORT; FACADES;
D O I
10.1016/j.apenergy.2016.06.126
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The present paper describes a numerical and experimental testing of a thermal energy storage system (TES) that contains phase change material (PCM). The definitions and assumptions of the developed numerical models to assess the performance and to simulate the thermal energy behavior are presented. The numerical calculation was performed using a computational fluid dynamics (CFD) analysis, and a real scale test cell with two window shutters, one with and the other without phase change materials, was used to validate the numerical model. The windows shutters were applied into two similar compartments that were tested and the thermal behavior was analyzed. The numerical models are based on 2D analysis and the indoor temperature comparison between the experimental and the simulated model are evaluated for both compartment models. To validate and evaluate the data agreement of the numerical results were used the most common statistical indexes (based on ASHRAE, IPMVP) and FEMP). According to the used criteria acceptance, the results of the numerical model presented good agreement and reliability, and the numerical model was considered as calibrated with well prediction data. Comparing the temperature improvement and the time delay between both compartments, the compartment with the PCM window shutter (i) decreased the maximum indoor temperature up to 8.7% for the warming period, (ii) increased 16.7% the minimum indoor temperature for the night period and (iii) increased the time delay 1 h for the maximum temperature peak and 30 min for the minimum temperature peak, compared with the reference compartment. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:64 / 84
页数:21
相关论文
共 56 条
[1]   Using phase change materials in window shutter to reduce the solar heat gain [J].
Alawadhi, Esam M. .
ENERGY AND BUILDINGS, 2012, 47 :421-429
[2]  
American Society of Heating R, 2002, ASHRAE GUID MEAS EN
[3]   Curbing global warming with phase change materials for energy storage [J].
Anisur, M. R. ;
Mahfuz, M. H. ;
Kibria, M. A. ;
Saidur, R. ;
Metselaar, I. H. S. C. ;
Mahlia, T. M. I. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 18 :23-30
[4]  
[Anonymous], 2009, World Energy Outlook 2009
[5]  
ANSYS, 2012, ANSYS FLUENT 14 5 TH
[6]  
ANSYS, 2012, ANSYS FLUENT 14 5 US
[7]   Phase change materials for building applications: A state-of-the-art review [J].
Baetens, Ruben ;
Jelle, Bjorn Petter ;
Gustavsen, Arild .
ENERGY AND BUILDINGS, 2010, 42 (09) :1361-1368
[8]   Materials used as PCM in thermal energy storage in buildings: A review [J].
Cabeza, L. F. ;
Castell, A. ;
Barreneche, C. ;
de Gracia, A. ;
Fernandez, A. I. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (03) :1675-1695
[9]   Passive performance of glazed components in heating and cooling of an open-space office under controlled indoor thermal comfort [J].
Cappelletti, Francesca ;
Prada, Alessandro ;
Romagnoni, Piercarlo ;
Gasparella, Andrea .
BUILDING AND ENVIRONMENT, 2014, 72 :131-144
[10]   Seasonal shading of vertical south-facades with prismatic panes [J].
Christoffers, D .
SOLAR ENERGY, 1996, 57 (05) :339-343