Kilovoltage intrafraction monitoring for real-time image guided adaptive radiotherapy reduces total dose for lung SABR

被引:9
作者
Juneja, Prabhjot [1 ,2 ,3 ]
Caillet, Vincent [1 ,2 ,3 ]
Shaw, Tom [2 ,3 ]
Martland, Judith [1 ]
Booth, Jeremy T. [1 ,2 ,3 ]
机构
[1] Royal North Shore Hosp, Northern Sydney Canc Ctr, Level 1,Reserve Rd, St Leonards, NSW 2065, Australia
[2] Univ Sydney, Sch Phys, Sydney, NSW, Australia
[3] Univ Sydney, Sch Med, Sydney, NSW, Australia
关键词
Lung cancer; Real time adaptive radiotherapy; MLC tracking; Imaging dose; STEREOTACTIC ABLATIVE RADIOTHERAPY; BEAM COMPUTED-TOMOGRAPHY; RADIATION-THERAPY; TUMOR POSITION; MLC TRACKING; GUIDANCE; MANAGEMENT;
D O I
10.1016/j.radonc.2016.08.030
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
This study presents estimation of typical kV fluoroscopic imaging doses for image-guided real-time adaptive radiotherapy. For a cohort of 10 lung SABR patients the estimated imaging dose to ipsi-lateral lung with real-time adaptation is 9.9-15.1 cGy, which is less than the extra lung dose from treatment with potentially larger ITV-based PTV approach. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:15 / 18
页数:4
相关论文
共 27 条
  • [1] Accuray, 2008, ACC ACH MIL 150 CYB
  • [2] Asa Palm, 2010, J APPL CLIN MED PHYS, V11
  • [3] Aukett R J, 2005, Phys Med Biol, V50, P2739, DOI 10.1088/0031-9155/50/12/001
  • [4] Effect of MLC tracking latency on conformal volumetric modulated arc therapy (VMAT) plans in 4D stereotactic lung treatment
    Bedford, James L.
    Fast, Martin F.
    Nil, Simeon
    McDonald, Fiona M. A.
    Ahmed, Merina
    Hansen, Vibeke N.
    Oelfke, Uwe
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 117 (03) : 491 - 495
  • [5] Stereotactic body radiation therapy: The report of AAPM Task Group 101
    Benedict, Stanley H.
    Yenice, Kamil M.
    Followill, David
    Galvin, James M.
    Hinson, William
    Kavanagh, Brian
    Keall, Paul
    Lovelock, Michael
    Meeks, Sanford
    Papiez, Lech
    Purdie, Thomas
    Sadagopan, Ramaswamy
    Schell, Michael C.
    Salter, Bill
    Schlesinger, David J.
    Shiu, Almon S.
    Solberg, Timothy
    Song, Danny Y.
    Stieber, Volker
    Timmerman, Robert
    Tome, Wolfgang A.
    Verellen, Dirk
    Wang, Lu
    Yin, Fang-Fang
    [J]. MEDICAL PHYSICS, 2010, 37 (08) : 4078 - 4101
  • [6] Clinical Impact of MLC Tracking for Lung SABR
    Caillet, V.
    Colvill, E.
    Szymura, K.
    Stevens, M.
    Booth, J.
    Keall, P.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3648 - 3649
  • [7] Caillet V, 2015, EPSM
  • [8] Measurement of patient imaging dose for real-time kilovoltage x-ray intrafraction tumour position monitoring in prostate patients
    Crocker, James K.
    Ng, Jin Aun
    Keall, Paul J.
    Booth, Jeremy T.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (10) : 2969 - 2980
  • [9] A model for decision making for the use of radiotherapy in lung cancer
    Delaney, G
    Barton, M
    Jacob, S
    Jalaludin, B
    [J]. LANCET ONCOLOGY, 2003, 4 (02) : 120 - 128
  • [10] Reducing radiation exposure to patients from kV-CBCT imaging
    Ding, George X.
    Munro, Peter
    Pawlowski, Jason
    Malcolm, Arnold
    Coffey, Charles W.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 97 (03) : 585 - 592