Complications of volar plating of distal radius fractures

被引:2
作者
Rampold, Michele [1 ]
Marsico, Salvatore [1 ]
机构
[1] Orthopaed & Traumatol Ctr, Dept Hand Surg Microsurg & Limb Replantat, Rome, Italy
来源
ACTA ORTHOPAEDICA BELGICA | 2007年 / 73卷 / 06期
关键词
distal radius fractures; volar plate fixation; complications;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Open reduction and internal fixation has been shown to be effective in the treatment of unstable distal radius fractures. When a dorsal approach is used, extensor tendons rupture or irritation are frequent and well known complications. Complications associated with volar plate fixation have not been studied to the same extent. In this study a homogenous series of 90 patients treated by volar plate fixation were retrospectively evaluated, focusing on the complications observed. The overall rate of complications was 8% (7 cases). Tendon rupture or irritation of extensor (3 cases) and flexor tendons (2 cases) were the complications most frequently seen. All but one were clearly related to direct attritional damage of the tendon caused by the prominent edge of the plate or by protruding screw tips. Loss of reduction requiring repeat internal fixation was observed in one marginal shear fracture involving the Innate facet fragment. One patient had a carpal tunnel release owing to median nerve irritation. In this study, volar plate fixation appeared as a safe procedure in the management of unstable distal radius fractures, with a low rate of complications. Accurate placement of the plate and exact measurement of the screws may further minimize the incidence of complications. When radiographs reveal conditions that may predispose to tendon attritional lesions (prominent edge of the plate, dorsal protrusion of the screw tips) we strongly recommend early removal of the fixation device.
引用
收藏
页码:714 / 719
页数:6
相关论文
共 19 条
[1]   Palmar locking plate for treatment of unstable dorsal dislocated distal radius fractures [J].
Arora, R ;
Lutz, M ;
Fritz, D ;
Zimmermann, R ;
Oberladstätter, J ;
Gabl, M .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2005, 125 (06) :399-404
[2]   OPEN REDUCTION AND INTERNAL-FIXATION OF COMMINUTED, INTRAARTICULAR FRACTURES OF THE DISTAL RADIUS [J].
AXELROD, TS ;
MCMURTRY, RY .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1990, 15A (01) :1-11
[3]   Rupture of flexor pollicis longus tendon - A complication of volar plating of the distal radius [J].
Bell, JSP ;
Wollstein, R ;
Citron, ND .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (02) :225-226
[4]   THE OUTCOME OF FRACTURES OF THE DISTAL RADIUS IN YOUNG-ADULTS [J].
BOYD, LG ;
HORNE, JG .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1988, 19 (02) :97-100
[5]   Open reduction and internal fixation of intra articular and unstable fractures of the distal radius using the AO distal radius plate [J].
Campbell, DA .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2000, 25B (06) :528-534
[6]   Open reduction and internal fixation of unstable distal radius fractures with a low-profile plate: A multicenter study of 73 fractures [J].
Carter, PR ;
Frederick, HA ;
Laseter, GF .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (02) :300-307
[7]  
Constantine KJ, 2002, ORTHOPEDICS, V25, P125
[8]   Radial artery pseudoaneurysm complication from use of AO/ASIF volar distal radius plate: A case report [J].
Dao, KD ;
Venn-Watson, E ;
Shin, AY .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2001, 26A (03) :448-453
[9]   Osteosynthesis of distal radial fractures with a volar locking screw plate system [J].
Drobetz, H ;
Kutscha-Lissberg, E .
INTERNATIONAL ORTHOPAEDICS, 2003, 27 (01) :1-6
[10]   Treatment of displaced intra-articular fractures of the distal end of the radius with plates [J].
Fitoussi, F ;
Ip, WY ;
Chow, SP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (09) :1303-1312