A two-dimensional approach for lossless EEG compression

被引:58
作者
Srinivasan, K. [1 ,2 ]
Dauwels, Justin [2 ]
Reddy, M. Ramasubba [1 ]
机构
[1] Indian Inst Technol, Dept Appl Mech, Biomed Engn Grp, Madras 600036, Tamil Nadu, India
[2] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore 639798, Singapore
关键词
Arithmetic coding; Correlation coefficient; Electroencephalogram (EEG); JPEG2000; Relative energy concentration; SPIHT; PERFORMANCE EVALUATION; IMAGE COMPRESSION; WAVELET TRANSFORM; SIGNALS; ALGORITHM; SCHEME;
D O I
10.1016/j.bspc.2011.01.004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper, we study various lossless compression techniques for electroencephalograph (EEG) signals. We discuss a computationally simple pre-processing technique, where EEG signal is arranged in the form of a matrix (2-D) before compression. We discuss a two-stage coder to compress the EEG matrix, with a lossy coding layer (SPIHT) and residual coding layer (arithmetic coding). This coder is optimally tuned to utilize the source memory and the lid. nature of the residual. We also investigate and compare EEG compression with other schemes such as JPEG2000 image compression standard, predictive coding based shorten, and simple entropy coding. The compression algorithms are tested with University of Bonn database and Physiobank Motor/Mental Imagery database. 2-D based compression schemes yielded higher lossless compression compared to the standard vector-based compression, predictive and entropy coding schemes. The use of pre-processing technique resulted in 6% improvement, and the two-stage coder yielded a further improvement of 3% in compression performance. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:387 / 394
页数:8
相关论文
共 40 条
[1]   Reversible integer-to-integer wavelet transforms for image compression: Performance evaluation and analysis [J].
Adams, MD ;
Kossentini, F .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2000, 9 (06) :1010-1024
[2]   Indications of nonlinear deterministic and finite-dimensional structures in time series of brain electrical activity: Dependence on recording region and brain state [J].
Andrzejak, RG ;
Lehnertz, K ;
Mormann, F ;
Rieke, C ;
David, P ;
Elger, CE .
PHYSICAL REVIEW E, 2001, 64 (06) :8-061907
[3]  
[Anonymous], IEEE INT S CIRC SYST
[4]  
[Anonymous], 2 NAT C BIOM IIT ROO
[5]  
[Anonymous], IEEE 17 ANN C ENG ME
[6]  
[Anonymous], INT C INF COMM SIGN
[7]  
[Anonymous], CUEDFINFENTR156
[8]  
[Anonymous], LOSSLESS COMPRESSION
[9]  
[Anonymous], P IEEE INT S CIRC SY
[10]  
[Anonymous], 6 INT C SIGN PROC