Peak distortions arising from large-volume injections in supercritical fluid chromatography

被引:24
作者
Dai, Yun [1 ]
Li, Geng [1 ]
Rajendran, Arvind [1 ,2 ]
机构
[1] Nanyang Technol Univ, Sch Chem & Biomed Engn, Singapore 637459, Singapore
[2] Univ Alberta, Dept Chem & Mat Engn, Edmonton, AB T6G 2V4, Canada
关键词
Supercritical fluid chromatography; Carbon dioxide; Injection; Modeling; Viscous fingering; COLUMN EFFICIENCY; PRESSURE-DROP; SOLUTE RETENTION; CARBON-DIOXIDE; SOLVENT; SEPARATION; ISOTHERMS; VISCOSITY;
D O I
10.1016/j.chroma.2015.02.063
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Preparative separations in supercritical fluid chromatography (SFC) involve the injection of large volumes of the solute. In SFC, the mobile phase is typically high pressure CO2 + modifier and the solute to be injected is usually dissolved in the modifier. Two-types of injection methods, modifier-stream and mixed-stream, are common in commercial preparative SFC systems. In modifier-stream injection, the injection is made in the modifier stream which is later mixed with the CO2 stream, while in the mixed-stream injection, the injection is made in a mixed CO2 + modifier stream. In this work a systematic experimental and modelling study of the two techniques is reported using single-enantiomers of flurbiprofen on Chiralpak AD-H with CO2 + methanol as the mobile phase. While modifier-stream injection shows non-distorted peaks, mixed-stream injection results in severe peak-distortion. By comparing the modelling and experimental results, it is shown that the modifier "plug" introduced in the mixed-stream injection is the primary cause of the peak distortions. The experimental results also point to the possible existence of viscous fingering which contributes to further peak distortion. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:91 / 99
页数:9
相关论文
共 35 条
[1]  
Berger T.A., 2003, METHOD SAMPLE INJECT
[2]   Visualization of viscous fingering in chromatographic columns [J].
Broyles, BS ;
Shalliker', RA ;
Cherrak, DE ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 1998, 822 (02) :173-187
[3]   Visualising the onset of viscous fingering in chromatography columns [J].
Catchpoole, Heather J. ;
Shalliker, R. Andrew ;
Dennis, Gary R. ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1117 (02) :137-145
[4]   Solubility of Flurbiprofen in CO2 and CO2 + Methanol [J].
Chin, Gui Jin ;
Chee, Zi Hui ;
Chen, Wenda ;
Rajendran, Arvind .
JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2010, 55 (04) :1542-1546
[5]   EFFECT OF SAMPLE VISCOSITY IN HIGH-PERFORMANCE SIZE-EXCLUSION CHROMATOGRAPHY AND ITS CONTROL [J].
CZOK, M ;
KATTI, AM ;
GUIOCHON, G .
JOURNAL OF CHROMATOGRAPHY, 1991, 550 (1-2) :705-719
[6]   THE CHANGE OF PRESSURE-DROP DURING LARGE-SCALE CHROMATOGRAPHY OF VISCOUS SAMPLES [J].
FELINGER, A ;
GUIOCHON, G .
BIOTECHNOLOGY PROGRESS, 1993, 9 (05) :450-455
[7]   Enantioselective chromatography as a powerful alternative for the preparation of drug enantiomers [J].
Francotte, ER .
JOURNAL OF CHROMATOGRAPHY A, 2001, 906 (1-2) :379-397
[8]   Preparative liquid chromatography [J].
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2002, 965 (1-2) :129-161
[9]  
Guiochon G., 2006, FUNDAMENTALS PREPARA, V2nd ed.
[10]   Fundamental challenges and opportunities for preparative supercritical fluid chromatography [J].
Guiochon, Georges ;
Tarafder, Abhijit .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (08) :1037-1114