Detection and identification of nucleic acid engineered fluorescent labels in submicrometre fluidic channels

被引:29
作者
Stavis, SM
Edel, JB
Li, YG
Samiee, KT
Luo, D
Craighead, HG [1 ]
机构
[1] Cornell Univ, Sch Appl & Engn Phys, Ithaca, NY 14853 USA
[2] Cornell Univ, Dept Biol & Environm Engn, Ithaca, NY 14853 USA
关键词
D O I
10.1088/0957-4484/16/7/002
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Nucleic acid engineers have created nanoscale fluorescent labels that are uniquely identifiable by the number of conjugated fluorophores, and with binding characteristics that permit recognition of individual specific biomolecules. The viability of this technology for use in multi-analyte homogeneous assays depends on the ability to optically detect individual labels, and distinguish the fluorescence emission of each label. We describe the use of fluidic channels with submicrometre dimensions to rapidly detect individual labels in solution. Labels with small differences in fluorophore composition were differentiated with varying degrees of accuracy. Labels were synthesized at the molecular level from dendrimer-like DNA, with the identity encoded into the number of Alexa Fluor 488 and BODIPY 630/650 fluorophores conjugated with the structure. To explore the decoding resolution limit, labels with a single fluorophore of each colour were detected, and were found to be distinguishable as a group, but not individually, from labels with one additional red fluorophore. Labels with one green and three red fluorophores were individually distinguishable with greater than 80% accuracy from labels with one red and three green fluorophores. Photon counting histograms were analysed to differentiate the various labels, and fluorescence correlation spectroscopy was used to measure their mobilities. Fluidic channels were fabricated in fused silica with a 500 nm square cross section, resulting in a focal volume or approximately 500 al. Because the entire channel width was illuminated, every fluorescent molecule in solution passing through the channel was uniformly excited and analyzed. Flow control enabled a balance of rapid data acquisition and efficient fluorescence collection with these nanoscale systems.
引用
收藏
页码:S314 / S323
页数:10
相关论文
共 23 条
[1]   Two-color fluorescence in flow cytometry DNA sizing: Identification of single molecule fluorescent probes [J].
Agronskaia, A ;
Schins, JM ;
de Grooth, BG ;
Greve, J .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4684-4689
[2]  
Ambrose WP, 1999, CYTOMETRY, V36, P224, DOI 10.1002/(SICI)1097-0320(19990701)36:3<224::AID-CYTO12>3.3.CO
[3]  
2-A
[4]   Biased diffusion, optical trapping, and manipulation of single molecules in solution [J].
Chiu, DT ;
Zare, RN .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1996, 118 (27) :6512-6513
[5]   Fluorescence intensity fluctuations of individual labeled DNA fragments and a DNA binding protein in solution at the single molecule level: A comparison of photobleaching, diffusion, and binding dynamics [J].
Daniel, DC ;
Thompson, M ;
Woodbury, NW .
JOURNAL OF PHYSICAL CHEMISTRY B, 2000, 104 (06) :1382-1390
[6]  
DEMELLO A, 1996, SURFACE ANAL TECHNIQ, P1
[7]  
Doornbos RMP, 1997, CYTOMETRY, V29, P204, DOI 10.1002/(SICI)1097-0320(19971101)29:3<204::AID-CYTO3>3.0.CO
[8]  
2-B
[9]   Detection and enumeration of single nanometric particles: A confocal optical design for fluorescence flow cytometry [J].
Ferris, MM ;
Rowlen, KL .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (06) :2404-2410
[10]   Focal volume confinement by submicrometer-sized fluidic channels [J].
Foquet, M ;
Korlach, J ;
Zipfel, WR ;
Webb, WW ;
Craighead, HG .
ANALYTICAL CHEMISTRY, 2004, 76 (06) :1618-1626