A locking compression plate as an external fixator for treating infected nonunion of the humeral diaphysis

被引:10
|
作者
Xiao, Cong [1 ]
Tang, Fan [1 ]
Zhou, Yong [1 ]
Zhang, Wenli [1 ]
Luo, Yi [1 ]
Duan, Hong [1 ]
Tu, Chongqi [1 ]
机构
[1] West China Hosp, Dept Orthoped, 37 Guoxue Xiang, Chengdu 610041, Sichuan, Peoples R China
来源
BMC SURGERY | 2016年 / 16卷
关键词
Nonunion; Humeral diaphysis; Infection; External fixator; Plate; DISTAL TIBIAL FRACTURES; SURGICAL-TREATMENT; FAILURE;
D O I
10.1186/s12893-016-0167-9
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Infected nonunion of the humeral diaphysis is a challenging problem for orthopedic surgeons. This study aimed to evaluate the outcome of using a locking compression plate (LCP) as a definitive external fixator in the management of infected nonunion of the humeral diaphysis after failure of internal fixation. Methods: We retrospectively reviewed a series of seven patients with infected nonunion of the humeral diaphysis treated with an LCP as an external fixator between June 2010 and August 2014. There were five males and two females, with an average age of 40.9 years. Six out of seven patients had been definitively diagnosed with infection due to known bacteria by germiculture. The clinical and radiographic outcomes were retrospectively evaluated. Results: All patients were followed-up for a mean period of 26.3 months (range 12-48 months). All fractures obtained complete bone union, and the average time to bone union was 7.9 months (range 3.5-15 months). All infections were eventually resolved without any recurrence of deep infection. Pin tract infection was only seen in one case. Only one patient had transient radial nerve palsy after surgery for traction. The average shortening length of the affected upper limb was 3 cm (range 2-4 cm) compared with the contralateral limb. At the last follow-up, the average Disabilities of the Arm, Shoulder and Hand score of the involved limbs was 3.2 (range 0-13.4). All patients obtained excellent or good functional results, and returned to their original work. Conclusions: The novel use of an LCP as a definitive external fixator was an effective method for treating infected nonunion of the humeral diaphysis. However, a large-scale prospective clinical study is still needed to verify these findings.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A locking compression plate as an external fixator for treating infected nonunion of the humeral diaphysis
    Cong Xiao
    Fan Tang
    Yong Zhou
    Wenli Zhang
    Yi Luo
    Hong Duan
    Chongqi Tu
    BMC Surgery, 16
  • [2] Locking Compression Plate as an External Fixator for the Treatment of Tibia Infected Bone Defects
    Xiao, Hong
    Wang, Shulin
    Wang, Feibo
    Dong, Sun
    Shen, Jie
    Xie, Zhao
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2023, 161 (03): : 311 - 317
  • [3] Delayed and non-union of the humeral diaphysis -: compression plate or internal plate fixator?
    Wenzl, ME
    Porté, T
    Fuchs, S
    Faschingbauer, M
    Jürgens, C
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2004, 35 (01): : 55 - 60
  • [4] Using a reconstruction locking compression plate as external fixator in infected open clavicle fracture
    Sirisreetreerux, Norachart
    Sa-Ngasoongsong, Paphon
    Chanplakorn, Pongsthorn
    Kulachote, Noratep
    Laohajaroensombat, Sukij
    Suphachatwong, Chanyut
    Phiphobmongkol, Vajara
    Wajanavisit, Wiwat
    ORTHOPEDIC REVIEWS, 2013, 5 (02) : 52 - 55
  • [5] Treatment of the humeral shaft aseptic nonunion using plate or unilateral external fixator
    Dragoljub, Micic Ivan
    Borivoje, Mitkovic Milorad
    Svetomir, Mladenovic Desimir
    Zoran, Golubovic Velimir
    Jeon, In-Ho
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2008, 64 (05): : 1290 - 1296
  • [6] Stiffness of the locking compression plate as an external fixator for treating distal tibial fractures: a biomechanics study
    Liu, Wei
    Yang, Lihui
    Kong, Xiaochuan
    An, Likun
    Hong, Gang
    Guo, Zicheng
    Zang, Lei
    BMC MUSCULOSKELETAL DISORDERS, 2017, 18 : 1 - 6
  • [7] Stiffness of the locking compression plate as an external fixator for treating distal tibial fractures: a biomechanics study
    Wei Liu
    Lihui Yang
    Xiaochuan Kong
    Likun An
    Gang Hong
    Zicheng Guo
    Lei Zang
    BMC Musculoskeletal Disorders, 18
  • [8] Efficacy of a compliant semicircular Ilizarov pin fixator module for treating infected nonunion of the femoral diaphysis
    Khanfour, Ashraf A.
    El-Sayed, Mohamed M.
    STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2014, 9 (02): : 101 - 109
  • [9] Metaphyseal locking compression plate as an external fixator for the distal tibia
    Tulner, Sven A. F.
    Strackee, Simon D.
    Kloen, Peter
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (09) : 1923 - 1927
  • [10] Supercutaneous Plating: Use of a Locking Compression Plate as an External Fixator
    Kloen, Peter
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (01) : 72 - 75