Dose Average LET of Electrons Generated Outside of 6 MV X-Ray Small Radiotherapy Field Edges

被引:0
|
作者
Huerta-juan, Y. [1 ]
Xicohtencatl-hernandez, N. [2 ]
Massillon-JL, G. [3 ]
机构
[1] Univ Nacl Autonoma Mexico, Mexico City, DF, Mexico
[2] Univ Popular Autonoma Estado Puebla, Puebla, Mexico
[3] Univ Nacl Autonoma Mexico, Inst Fis, Mexico City, DF, Mexico
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
WE-C930-Ie
引用
收藏
页码:E494 / E494
页数:1
相关论文
共 50 条
  • [1] Linear energy transfer (LET) distribution outside small radiotherapy field edges produced by 6 MV X-rays
    Huerta-Juan, Y.
    Xicohtencatl-Hernandez, N.
    Massillon-JL, G.
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [2] Linear energy transfer (LET) distribution outside small radiotherapy field edges produced by 6 MV X-rays
    Y. Huerta-Juan
    N. Xicohténcatl-Hernández
    G. Massillon-JL
    Scientific Reports, 13
  • [3] Electron and Photon Energy Spectra Outside of 6 MV X-ray Small Radiotherapy Field Edges Produced by a Varian iX Linac
    Xicohtencatl-Hernandez, Nahum
    Moreno-Ramirez, Adriana
    Massillon-JL, Guerda
    FRONTIERS IN PHYSICS, 2021, 9
  • [4] Neutron dose from a 6-MV X-ray beam in radiotherapy
    Matsubara, Hiroaki
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2023, 16 (02) : 186 - 194
  • [5] Neutron dose from a 6-MV X-ray beam in radiotherapy
    Hiroaki Matsubara
    Radiological Physics and Technology, 2023, 16 : 186 - 194
  • [6] Depth dose-equivalent and effective energies of photoneutrons generated by 6-18 MV X-ray beams for radiotherapy
    d'Errico, F
    Luszik-Bhadra, M
    Nath, R
    Siebert, BRL
    Wolf, U
    HEALTH PHYSICS, 2001, 80 (01): : 4 - 11
  • [7] Absorbed dose and transmission factor in blocked fields for radiotherapy treatments with 6 MV X-ray
    Buenfil A.E.
    Rodríguez-González M.F.
    González G.R.
    Brandan M.E.
    Clinical & Translational Oncology, 2006, 8 (4): : 279 - 283
  • [8] Variations in 6MV x-ray radiotherapy build-up dose with treatment distance
    M. J. Butson
    T. Cheung
    P. K. N. Yu
    Australasian Physics & Engineering Sciences in Medicine, 2003, 26 (2): : 87 - 89
  • [9] Practical considerations for reporting surface dose in external beam radiotherapy: a 6 MV X-ray beam study
    Kim, J. -H.
    Hill, R.
    Kuncic, Z.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2012, 35 (03) : 271 - 282
  • [10] Practical considerations for reporting surface dose in external beam radiotherapy: a 6 MV X-ray beam study
    J.-H. Kim
    R. Hill
    Z. Kuncic
    Australasian Physical & Engineering Sciences in Medicine, 2012, 35 : 271 - 282