A Novel Low Unity-Gain Frequency and Low Power Consumption Instrumentation Amplifier Design for RuO2 Uric Acid Biosensor Measurement

被引:19
作者
Kuo, Po-Yu [1 ]
Chen, Yung-Yu [1 ]
机构
[1] Natl Yunlin Univ Sci & Technol, Grad Sch Elect Engn, Touliu 64002, Taiwan
关键词
Biosensor measurement system; instrumentation amplifier (IA); readout circuit; ruthenium dioxide (RuO2); uric acid (UA) biosensor; RUTHENIUM DIOXIDE; THIN-FILM; MEMBRANE; DRIFT; CMRR;
D O I
10.1109/TIM.2021.3060571
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this study, a novel low unity-gain frequency and low power consumption instrumentation amplifier (UGFPCIA) was designed and applied to the readout circuit of the potentiometric biosensor measurement system. The proposed UGFPCIA was developed using the Taiwan Semiconductor Manufacturing Company (TSMC) 0.18-mu m process technology, and simulated in a Laker analog design environment, and had a 1.5-V supply voltage for reduced power consumption. The uric acid (UA) biosensor based on RuO2 thin film was fabricated in this study. The sensing characteristics of the RuO2 UA biosensor were measured by the proposed UGFPCIA and the LT1167, a commercial instrumentation amplifier; then, their readout circuits were compared. According to the chip measurement results, the proposed UGFPCIA achieved a common-mode gain of -54 dB and a unity-gain frequency (UGF) of 588 kHz. Its power consumption was 397.92 mu W. Moreover, the measurement results showed that the sensitivity and linearity of the flexible arrayed RuO2 UA biosensor were 7.15 mV/(mg/dL) and 0.997, respectively. The LT1167 used a 2.3-V minimum supply voltage, while the proposed UGFPCIA used a 1.5-V minimum supply voltage; the power consumption is 84% lower than the former. This indicates that UGFPCIA was more stable during the measurement process and consumes lesser power.
引用
收藏
页数:9
相关论文
共 36 条
  • [1] Abhilash KN, 2013, 2013 IEEE ASIA PACIFIC CONFERENCE ON POSTGRADUATE RESEARCH IN MICROELECTRONICS & ELECTRONICS (PRIMEASIA), P40, DOI 10.1109/PrimeAsia.2013.6731175
  • [2] CMRR in Voltage-Op-Amp-Based Current-Mode Instrumentation Amplifiers (CMIA)
    Azhari, Seyed Javad
    Fazlalipoor, Hossein
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (03) : 563 - 569
  • [3] The impact of active electrode guard layer in capacitive measurements of biosignals
    Bednar, Tadeas
    Babusiak, Branko
    Smondrk, Maros
    Cap, Ivo
    Borik, Stefan
    [J]. MEASUREMENT, 2021, 171
  • [4] Introduction to biosensors
    Bhalla, Nikhil
    Jolly, Pawan
    Formisano, Nello
    Estrela, Pedro
    [J]. BIOSENSOR TECHNOLOGIES FOR DETECTION OF BIOMOLECULES, 2016, 60 (01): : 1 - 8
  • [5] Portable urea biosensor based on the extended-gate field effect transistor
    Chen, JC
    Chou, JC
    Sun, TP
    Hsiung, SK
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2003, 91 (1-3) : 180 - 186
  • [6] Chou J.-C., 2020, IEEE SENSORS J, V21, P7218
  • [7] Development of a Disposable All-Solid-State Ascorbic Acid Biosensor and Miniaturized Reference Electrode Fabricated on Single Substrate
    Chou, Jung Chuan
    Tsai, Yen His
    Chen, Chien Cheng
    [J]. IEEE SENSORS JOURNAL, 2008, 8 (9-10) : 1571 - 1577
  • [8] Integrating a Plastic Glucose Biosensor Based on Arrayed Screen-Printed Electrodes Utilizing Magnetic Beads with a Microfluidic Device
    Chou, Jung-Chuan
    Lin, Si-Hong
    Kuo, Po-Yu
    Lai, Chih-Hsien
    Nien, Yu-Hsun
    Lai, Tsu-Yang
    Su, Tzu-Yu
    [J]. IEEE JOURNAL OF THE ELECTRON DEVICES SOCIETY, 2019, 7 (01): : 1151 - 1160
  • [9] Immobilization of the urease on eggshell membrane and its application in biosensor
    D'Souza, S. F.
    Kumar, Jitendra
    Jha, Sandeep Kumar
    Kubal, B. S.
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2013, 33 (02): : 850 - 854
  • [10] BIENZYME REACTOR FOR ELECTROCHEMICAL DETECTION OF LOW CONCENTRATIONS OF URIC-ACID AND GLUCOSE
    ELEKES, O
    MOSCONE, D
    VENEMA, K
    KORF, J
    [J]. CLINICA CHIMICA ACTA, 1995, 239 (02) : 153 - 165