Quantitative comparison of five current protocols in gait analysis

被引:237
作者
Ferrari, Alberto [1 ,2 ]
Benedetti, Maria Grazia [1 ]
Pavan, Esteban [3 ]
Frigo, Carlo [3 ]
Bettinelli, Dario [4 ]
Rabuffetti, Marco [5 ]
Crenna, Paolo
Leardini, Alberto [1 ]
机构
[1] Univ Bologna, DEIS, Ist Ortoped Rizzoli, Movement Anal Lab, I-40136 Bologna, Italy
[2] Univ Bologna, Dept Elect Comp Sci & Syst, I-40136 Bologna, Italy
[3] Politecn Milan, Movement Biomech & Motor Control Lab, I-20133 Milan, Italy
[4] Aur SRL, Milan, Italy
[5] Fdn Don Carlo Gnocchi IRCCS, Ctr Bioingn, Milan, Italy
关键词
gait analysis; inter-protocol repeatability; kinematics; kinetics; data reduction;
D O I
10.1016/j.gaitpost.2007.11.009
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Data collection and reduction procedures, coherently structured in protocols, are necessary in gait analysis to make kinematic and kinetic measurements clinically comprehensible. The current protocols differ considerably for the marker-set and for the biomechanical model implemented. Nevertheless, conventional gait variables are compared without full awareness of these differences. A comparison was made of five worldwide representative protocols by analysing kinematics and kinetics of the trunk, pelvis and lower limbs exactly over the same gait cycles. A single comprehensive arrangement of markers was defined by merging the corresponding five marker-sets. This resulted in 60 markers to be positioned either on the skin or on wands, and in 16 anatomical landmark calibrations to be performed with an instrumented pointer. Two healthy subjects and one patient who had a special two degrees of freedom knee prosthesis implanted were analysed. Data from Up-right posture and at least three gait repetitions were collected. Five corresponding experts participated in the data collection and analysed independently the data according to their own procedures. All five protocols showed good intra-protocol repeatability. Joint flexion/extension showed good correlations and a small bias among protocols. Out-of-sagittal plane rotations revealed worse correlations, and in particular knee abduction/adduction had opposite trends. Joint moments compared well, despite the very different methods implemented. The abduction/adduction at the prosthetic knee, which was fully restrained, revealed an erroneous rotation as large as 30 degrees in one protocol. Higher correlations were observed between the protocols with similar biomechanical models, whereas little influence seems to be ascribed to the marker-set. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:207 / 216
页数:10
相关论文
共 36 条
[11]  
Dorociak RD, 2002, GAIT POSTURE, V16, pS102
[12]   Functionally oriented and clinically feasible quantitative gait analysis method [J].
Frigo, C ;
Rabuffetti, M ;
Kerrigan, DC ;
Deming, LC ;
Pedotti, A .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1998, 36 (02) :179-185
[13]   Multifactorial estimation of hip and knee joint centres for clinical application of gait analysis [J].
Frigo, C ;
Rabuffetti, M .
GAIT & POSTURE, 1998, 8 (02) :91-102
[14]  
GAGE JR, 1993, CLIN ORTHOP RELAT R, P126
[15]  
GORTON G, 2002, GAIT POSTURE S1, V16, pS65
[16]  
Hebert D., 2001, GAIT POSTURE, V13, P247, DOI DOI 10.1016/J.GAITP0ST.2008.10.060
[17]   REPEATABILITY OF KINEMATIC, KINETIC, AND ELECTROMYOGRAPHIC DATA IN NORMAL ADULT GAIT [J].
KADABA, MP ;
RAMAKRISHNAN, HK ;
WOOTTEN, ME ;
GAINEY, J ;
GORTON, G ;
COCHRAN, GVB .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1989, 7 (06) :849-860
[18]   MEASUREMENT OF LOWER-EXTREMITY KINEMATICS DURING LEVEL WALKING [J].
KADABA, MP ;
RAMAKRISHNAN, HK ;
WOOTTEN, ME .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1990, 8 (03) :383-392
[19]   Human movement analysis using stereophotogrammetry - Part 3. Soft tissue artifact assessment and compensation [J].
Leardini, A ;
Chiari, L ;
Della Croce, U ;
Cappozzo, A .
GAIT & POSTURE, 2005, 21 (02) :212-225
[20]  
LEARDINI A, 2007, GAIT POSTURE 0207