Five-year Follow-up of Intracardiac Echocardiography-assisted Transcatheter Closure of Complex Ostium Secundum Atrial Septal Defect

被引:23
|
作者
Rigatelli, Gianluca [1 ]
Dell' Avvocata, Fabio [1 ]
Cardaioli, Paolo [1 ]
Giordan, Massimo [1 ]
Vassiliev, Dobrin [2 ]
Nghia, Nguyen T. [3 ]
Chen, Jack P. [4 ]
机构
[1] Rovigo Gen Hosp, Sect Adult Congenital & Adult Heart Dis, I-45100 Rovigo, Italy
[2] Natl Heart Inst, Sofia, Bulgaria
[3] Cho Rey Hosp, Intervent Cardiol Dept, Ho Chi Minh City, Vietnam
[4] St Josephs Heart & Vasc Inst, Atlanta, GA USA
关键词
Atrial Septal Defect; Percutaneous; Catheter-based Closure; Intravascular; PERCUTANEOUS CLOSURE; DEVICE; ADULTS; COMPLICATIONS; FEASIBILITY; OCCLUSION; OCCLUDER;
D O I
10.1111/j.1747-0803.2011.00567.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective. We sought to prospectively evaluate long-term follow-up results of intracardiac echocardiography-aided transcatheter closure of complex atrial septal defects (ASD) in the adults. Design and Settings. Prospective multicenter registry in tertiary care hospitals. Patients and Interventions. Over a 5-year period, we prospectively enrolled 56 patients (mean age 49 +/- 16.7 years, 24 females) who have been referred to our center for catheter-based closure of complex secundum ASD (> 25 mm diameter, deficiency of >= 1 rim, multiple secundum ASD, multiperforated ASD, associated incomplete floor of the fossa ovalis with or without aneurysm, embryonic remnants of incomplete atrial septation). All patients were screened by means of transesophageal echocardiography before the operation. Eligible patients underwent intracardiac echocardiography study and closure attempt. Results. Forty patients underwent a transcatheter closure attempt: transesophageal echocardiography-planned device type and size were modified in 32 patients (64%). Rates of procedural success, predischarge occlusion, and major complications rate were 100%, 90%, and 2%, respectively. On mean follow-up of 5.4 +/- 1.8 years, the follow-up occlusion rate was 98%. During follow-up, only one case of permanent atrial fibrillation was observed. There were no cases of aortic/atrial erosion, device thrombosis, or new atrioventricular valve dysfunction. Conclusions. Intracardiac echocardiography-guided complex secundum ASD transcatheter closure is safe and effective and appears to have excellent long-term results, thus minimizing potential complications resulting from the complex anatomy.
引用
收藏
页码:103 / 110
页数:8
相关论文
共 50 条
  • [31] Mid-to-long-term follow-up results of transcatheter closure of atrial septal defect in patients older than 40 years
    Wang, Jou-Kou
    Chiu, Shuenn-Nan
    Lin, Ming-Tai
    Chen, Chun-An
    Lu, Chun-Wei
    Wu, Mei-Hwan
    HEART AND VESSELS, 2017, 32 (04) : 467 - 473
  • [32] Management of ostium secundum atrial septal defect in the era of percutaneous trans-catheter device closure: 7-Year experience at a single institution
    Hoashi, Takaya
    Yazaki, Satoshi
    Kagisaki, Koji
    Kitano, Masataka
    Kubota, Sayaka Miura
    Shiraishi, Isao
    Ichikawa, Hajime
    JOURNAL OF CARDIOLOGY, 2015, 65 (5-6) : 418 - 422
  • [33] Transcatheter closure of atrial septal communication: Impact on quality of life in mid-term follow-up
    Lelakowska, Maria
    Matusik, Pawel Tomasz
    Podolec, Piotr Stanislaw
    Olszowska, Maria
    Nessler, Jadwiga Maria
    Podolec, Natalia
    Przewlocki, Tadeusz
    Komar, Monika
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2019, 28 (08): : 1079 - 1085
  • [34] Visualization of secundum atrial septal defect using transthoracic three-dimensional echocardiography in children: Implications for transcatheter closure
    Lu, JH
    Hsu, TL
    Hwang, B
    Weng, ZC
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1998, 15 (07): : 651 - 659
  • [35] Complete Transthoracic Echocardiography for the Assessment and Guidance of Percutaneous Atrial Septal Defect Closure in Adults without Balloon Sizing: An Observed Study with a 10-Year Follow-Up
    Xie, Lin-Feng
    Lin, Yong
    Chen, Mei-Fang
    Zhang, Gui-Can
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2023, 10 (08)
  • [36] Velocity Vector Imaging Assessment of Functional Change in the Right Ventricle during Transcatheter Closure of Atrial Septal Defect by Intracardiac Echocardiography
    Jung, Se Yong
    Shin, Jae Il
    Choi, Jae Young
    Park, Su-Jin
    Kim, Nam Kyun
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (04)
  • [37] Functional Tricuspid Regurgitation After Transcatheter Closure of Atrial Septal Defect in Adult Patients Long-Term Follow-Up
    Takaya, Yoichi
    Akagi, Teiji
    Kijima, Yasufumi
    Nakagawa, Koji
    Ito, Hiroshi
    JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (21) : 2211 - 2218
  • [38] Device closure of diverse layout of multi-hole secundum atrial septal defect: different techniques and long-term follow-up
    Farhaj, Zeeshan
    Li Hongxin
    Guo Wenbin
    Zhang, Wen-Long
    Liang, Fei
    Zhang, Hai-Zhou
    Yuan, Gui-Dao
    Zou, Cheng-Wei
    JOURNAL OF CARDIOTHORACIC SURGERY, 2019, 14 (1)
  • [39] Transcatheter Closure of Atrial Septal Defect in Children: Single-Center Experience, Mid-Term Follow-up Results
    Ozbay, Yesfa Sebnem
    Eker, Rukiye
    Dindar, Aygun
    Aydogan, Umrah
    Nisli, Kemal
    TURKISH ARCHIVES OF PEDIATRICS, 2022, 57 (04): : 406 - 412
  • [40] Safety of Occlutech Septal Occluder ACCELL Flex II for Transcatheter Closure of Secundum Atrial Septal Defects in Children: A Long-Term Follow-Up
    El-Sisi, Amal M.
    El-Saiedi, Sonia A.
    Ammar, Rasha
    Abdelhameed, Asmaa
    Hijazi, Ziyad M.
    Soliman, Mohammed M.
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2022, 2022