Five-year Follow-up of Intracardiac Echocardiography-assisted Transcatheter Closure of Complex Ostium Secundum Atrial Septal Defect

被引:23
|
作者
Rigatelli, Gianluca [1 ]
Dell' Avvocata, Fabio [1 ]
Cardaioli, Paolo [1 ]
Giordan, Massimo [1 ]
Vassiliev, Dobrin [2 ]
Nghia, Nguyen T. [3 ]
Chen, Jack P. [4 ]
机构
[1] Rovigo Gen Hosp, Sect Adult Congenital & Adult Heart Dis, I-45100 Rovigo, Italy
[2] Natl Heart Inst, Sofia, Bulgaria
[3] Cho Rey Hosp, Intervent Cardiol Dept, Ho Chi Minh City, Vietnam
[4] St Josephs Heart & Vasc Inst, Atlanta, GA USA
关键词
Atrial Septal Defect; Percutaneous; Catheter-based Closure; Intravascular; PERCUTANEOUS CLOSURE; DEVICE; ADULTS; COMPLICATIONS; FEASIBILITY; OCCLUSION; OCCLUDER;
D O I
10.1111/j.1747-0803.2011.00567.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective. We sought to prospectively evaluate long-term follow-up results of intracardiac echocardiography-aided transcatheter closure of complex atrial septal defects (ASD) in the adults. Design and Settings. Prospective multicenter registry in tertiary care hospitals. Patients and Interventions. Over a 5-year period, we prospectively enrolled 56 patients (mean age 49 +/- 16.7 years, 24 females) who have been referred to our center for catheter-based closure of complex secundum ASD (> 25 mm diameter, deficiency of >= 1 rim, multiple secundum ASD, multiperforated ASD, associated incomplete floor of the fossa ovalis with or without aneurysm, embryonic remnants of incomplete atrial septation). All patients were screened by means of transesophageal echocardiography before the operation. Eligible patients underwent intracardiac echocardiography study and closure attempt. Results. Forty patients underwent a transcatheter closure attempt: transesophageal echocardiography-planned device type and size were modified in 32 patients (64%). Rates of procedural success, predischarge occlusion, and major complications rate were 100%, 90%, and 2%, respectively. On mean follow-up of 5.4 +/- 1.8 years, the follow-up occlusion rate was 98%. During follow-up, only one case of permanent atrial fibrillation was observed. There were no cases of aortic/atrial erosion, device thrombosis, or new atrioventricular valve dysfunction. Conclusions. Intracardiac echocardiography-guided complex secundum ASD transcatheter closure is safe and effective and appears to have excellent long-term results, thus minimizing potential complications resulting from the complex anatomy.
引用
收藏
页码:103 / 110
页数:8
相关论文
共 50 条
  • [21] Transcatheter secundum atrial septal defect closure using intracardiac echocardiography in adult patient with azygos/hemiazygos continuation of the inferior vena cava
    Varotto, Leonardo
    Dotto, Alberto
    Spigolon, Luca
    Spadaro, Gian Luca
    Caprioglio, Francesco
    INTERNATIONAL JOURNAL OF CARDIOLOGY CONGENITAL HEART DISEASE, 2023, 12
  • [22] Recent Experience and Follow-Up After Surgical Closure of Secundum Atrial Septal Defect in 120 Children
    Geoffroy de Beco
    Natasha Mambour
    Christophe Vô
    Laetitia Vanhoutte
    Stéphane Moniotte
    Alain Poncelet
    Thierry Sluysmans
    Pediatric Cardiology, 2018, 39 : 1440 - 1444
  • [23] Transthoracic Echocardiography as a Measuring and Guiding Tool for Transcatheter Device Closure of Secundum Atrial Septal Defect in Young Children
    Sadiq, Nadeem
    Ullah, Maad
    Sultan, Mehboob
    Akhtar, Khurram
    JOURNAL OF INVASIVE CARDIOLOGY, 2014, 26 (06) : 245 - 248
  • [24] Transcatheter closure of atrial septal defect in the elderly: Early outcomes and mid-term follow-up
    Giordano, Mario
    Gaio, Gianpiero
    D'Alto, Michele
    Santoro, Giuseppe
    Scognamiglio, Giancarlo
    Bigazzi, Maurizio Cappelli
    Palladino, Maria Teresa
    Sarubbi, Berardo
    Golino, Paolo
    Russo, Maria Giovanna
    INTERNATIONAL JOURNAL OF CARDIOLOGY CONGENITAL HEART DISEASE, 2020, 1
  • [25] Value of the Ratio of Occluder Versus Atrial Septal Length for Predicting Arrhythmia Occurrence after Transcatheter Closure in Children with Ostium Secundum Atrial Septal Defect
    Jin Mei
    Ding Wen-Hong
    Wang Xiao-Fang
    Guo Bao-Jing
    Liang Yong-Mei
    Xiao Yan-Yan
    Sun Chu-Fan
    中华医学杂志英文版, 2015, 128 (12) : 1574 - 1578
  • [26] Value of the Ratio of Occluder Versus Atrial Septal Length for Predicting Arrhythmia Occurrence after Transcatheter Closure in Children with Ostium Secundum Atrial Septal Defect
    Jin, Mei
    Ding, Wen-Hong
    Wang, Xiao-Fang
    Guo, Bao-Jing
    Liang, Yong-Mei
    Xiao, Yan-Yan
    Sun, Chu-Fan
    CHINESE MEDICAL JOURNAL, 2015, 128 (12) : 1574 - 1578
  • [27] Long-term follow up after transcatheter closure of atrial septal defect and patent foramen vale in adults
    Jure, Dolenc
    Andraz, Cerar
    Marta, Cvijic
    Katja, Prokselj
    Mirta, Kozelj
    ZDRAVNISKI VESTNIK-SLOVENIAN MEDICAL JOURNAL, 2013, 82 (12): : 809 - 817
  • [28] Transcatheter closure of atrial septal defect using intracardiac echocardiography: a two-center, retrospective study
    Lucarelli, Katya
    Acquaviva, Tommaso
    Ferrero, Paolo
    De Cillis, Emanuela
    Casamassima, Vito
    Basile, Eloisa
    Cacciapaglia, Erasmo
    Iorio, Elia
    Martimucci, Marcello
    Cecere, Giacomo
    Petti, Pierpaolo
    Caruso, Rosa
    Langialonga, Tommaso
    Bortone, Alessandro
    Grimaldi, Massimo
    Chessa, Massimo
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2024, 25 (04) : 311 - 317
  • [29] Percutaneous transcatheter atrial septal defect closure with Amplatzer septal occluder device using three different techniques in three adult patients with complex ostium secundum type atrial defects
    Kilic, Teoman
    Sahin, Tayfun
    Ural, Ertan
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2013, 41 (02): : 148 - 153
  • [30] Percutaneous closure of secundum type atrial septal defects: More than 5-year follow-up
    Snijder, Roel J. R.
    Suttorp, Maarten J.
    Ten Berg, Jurren M.
    Post, Martijn C.
    WORLD JOURNAL OF CARDIOLOGY, 2015, 7 (03): : 150 - 156