PERFORMANCE ENHANCEMENT OF VAPOR COMPRESSION HEAT PUMPS BY A COOLED COMPRESSION CYCLE

被引:2
作者
Kermani, Nasrin Arjomand [1 ]
Madsen, John Terpollari [2 ]
Heerup, Christian [3 ]
Elmegaard, Brian [1 ]
机构
[1] Tech Univ Denmark, DK-2800 Lyngby, Denmark
[2] Joma Tech, DK-5792 Arslev, Denmark
[3] Danish Technol Inst, DK-2630 Taastrup, Denmark
来源
13TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS: NATURAL REFRIGERANT SOLUTIONS FOR WARM CLIMATE COUNTRIES | 2018年
关键词
Heat pump; Combined compressor-condenser unit; refrigerant injection; Mathematical model; COP; SCROLL COMPRESSOR; PRESSURE-DROP; EVAPORATION; SYSTEM;
D O I
10.18462/iir.gl.2018.1374
中图分类号
O414.1 [热力学];
学科分类号
摘要
The presented study proposes a configuration combining the compression and condensation processes in a single unit and evaporation and expansion in another separate unit for application in a vapor compression heat pump cycle. The cycle includes injection of refrigerant into the compressor at a certain temperature. This system makes it possible to match the temperature glide of the heat sink and source and simultaneously condense the refrigerant during the compression. A mathematical model of a complete cycle was made to study the system parameters and performance improvement of the cycle. Moreover, thermodynamic models of compression-condensation processes as well as a sensitivity analysis were developed to investigate the heat transfer inside the compressor-condenser unit and determine the injection conditions which can achieve the desirable requirements in the cycle model. Advantages such as eliminating thermodynamic losses associated with the desuperheating of refrigerant, reduction of compression work, available hot liquid at the compressor outlet for the district heating system and COP closer to the Lorenz COP can be obtained compared to the conventional cycle. The proposed cycle reached COP of 4.1 and 59 % Lorenz efficiency for a case related to R717 as working fluid and district heating production.
引用
收藏
页码:1154 / 1164
页数:11
相关论文
共 18 条
[1]   Droplet evaporation with reference to the effectiveness of water-mist cooling [J].
Barrow, H. ;
Pope, C. W. .
APPLIED ENERGY, 2007, 84 (04) :404-412
[2]   Performance of vapor compression systems with compressor oil flooding and regeneration [J].
Bell, Ian H. ;
Groll, Eckhard A. ;
Braun, James E. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (01) :225-233
[3]   Evaporation heat transfer and pressure drop of refrigerant R-410A flow in a vertical plate heat exchanger [J].
Hsieh, YY ;
Lin, TF .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2003, 125 (05) :852-857
[4]  
Hugenroth J., 2006, IHR-IRHACE Conference, P492
[5]   Heat transfer analysis of liquid piston compressor for hydrogen applications [J].
Kermani, Nasrin Arjomand ;
Rokni, Masoud .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2015, 40 (35) :11522-11529
[6]  
Klein S.A., 2017, Engineering Equation Solver (FChart Software)
[7]  
Lambers K.J., 2008, INT COMPR ENG C, P9
[9]   Oil flooded compression cycle enhancement for two-stage heat pump in cold climate region: System design and theoretical analysis [J].
Luo, Baojun .
ENERGY CONVERSION AND MANAGEMENT, 2016, 115 :52-59
[10]   Performance limit for economized cycles with continuous refrigerant injection [J].
Mathison, Margaret M. ;
Braun, James E. ;
Groll, Eckhard A. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (01) :234-242