Organ dose in cardiac dual-energy computed tomography: a Monte Carlo study

被引:0
|
作者
Pakravan, Delaram [1 ]
Mofrad, Farshid Babapour [1 ]
Deevband, Mohammad Reza [2 ]
Ghorbani, Mahdi [2 ]
Pouraliakbar, Hamidreza [3 ]
机构
[1] Islamic Azad Univ, Dept Med Radiat Engn, Sci & Res Branch, Tehran, Iran
[2] Shahid Beheshti Univ Med Sci, Sch Med, Biomed Engn & Med Phys Dept, Tehran, Iran
[3] Iran Univ Med Sci, Rajaie Cardiovasc Med & Res Ctr, Tehran, Iran
关键词
Monte Carlo simulation; Dual-energy computed tomography; Cardiac; Organ dose; Dose index; MULTIDETECTOR CT MDCT; IMAGE QUALITY; ANGIOGRAPHY; SCANNER; PATIENT; MODEL;
D O I
10.1007/s13246-021-01098-9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dual-energy computed tomography (DECT) has appeared as a novel approach with the aim of evaluating artery-related diseases. With the advent of DECT, concerns have been raised about the induction of diseases such as cancer due to high radiation exposure of patients. Therefore, the dose received by patients in DECT should be considered. The parameter most commonly used for patient dosimetry is the effective dose (ED). The purpose of this study is to model and validate a DECT scanner by a developed MCNP Monte Carlo code and to calculate the organ doses, the ED, and the conversion factor (k-factor) used in determining ED in the cardiac imaging protocol. To validate the DECT scanner simulation, a standard dosimetry body phantom was modeled in two radiation modes of single energy CT and DECT. The results of simulated CT dose index (CTDI) were compared with those of ImPACT or measurement data. Then dosimetry phantom was replaced by the male and female ORNL phantoms and the organ doses were calculated. The organ doses were also calculated by ImPACT dose software. In the initial validation stage, the minimum and maximum observed relative differences between results of MNCP simulation and measured were 2.77% and 5.79% for the central CTDI and 1.91% and 5.83% for the averaged peripheral CTDI, respectively. The mean ED of simulation and the ImPACT were 3.23 and 5.55 mSv/100 mAs, and the mean k-factor was 0.016 and 0.032 mSv mGy(-1) cm(-1) in the male and female phantoms, respectively. The k-factor obtained for males is close to the currently used k-factor, but the k-factor for females is almost twice.
引用
收藏
页码:157 / 166
页数:10
相关论文
共 50 条
  • [31] Vascular Imaging: Utilization of Dual-Energy Computed Tomography
    Ahmed Alharthy
    Matthew D’Mello
    Hatim Alabsi
    Nicolas Murray
    Omar Metwally
    Khaled Y. Elbanna
    Mohammed F. Mohammed
    Faisal Khosa
    Current Radiology Reports, 7
  • [32] Dual-energy computed tomography angiography for evaluating the renal vascular variants
    Tao Xiao-feng
    Zhu Jing-qi
    Wu Ying-wei
    Tang Guang-yu
    Sri Yu-zhen
    Zhang Lei
    Lin Yi
    Wang Zhong-qiu
    CHINESE MEDICAL JOURNAL, 2013, 126 (04) : 650 - 654
  • [33] Vascular Imaging: Utilization of Dual-Energy Computed Tomography
    Alharthy, Ahmed
    D'Mello, Matthew
    Alabsi, Hatim
    Murray, Nicolas
    Metwally, Omar
    Elbanna, Khaled Y.
    Mohammed, Mohammed F.
    Khosa, Faisal
    CURRENT RADIOLOGY REPORTS, 2019, 7 (09)
  • [34] Dual-Energy Computed Tomography for Gout Diagnosis and Management
    Dalbeth, Nicola
    Choi, Hyon K.
    CURRENT RHEUMATOLOGY REPORTS, 2013, 15 (01)
  • [35] Optimization of low-dose scan parameters in dual-energy computed tomography for displaying the anterior cruciate ligament
    Bai, Rui
    Li, Xiangdong
    Li, Rurui
    He, Xiaohua
    Wen, Zhibo
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2020, 48 (07)
  • [36] A comprehensive review of dual-energy and multi-spectral computed tomography
    Garnett, Richard
    CLINICAL IMAGING, 2020, 67 : 160 - 169
  • [37] Dual-Energy Computed Tomography to Photon Counting Computed Tomography: Emerging Technological Innovations
    Srinivas-Rao, Shravya
    Cao, Jinjin
    Marin, Daniele
    Kambadakone, Avinash
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2023, 61 (06) : 933 - 944
  • [38] Myocardial iodine concentration measurement using dual-energy computed tomography for the diagnosis of cardiac amyloidosis: a pilot study
    Chevance, Virgile
    Damy, Thibaud
    Tacher, Vania
    Legou, Francois
    Ridouani, Fourat
    Luciani, Alain
    Kobeiter, Hicham
    Rahmouni, Alain
    Deux, Jean-Francois
    EUROPEAN RADIOLOGY, 2018, 28 (02) : 816 - 823
  • [39] Myocardial iodine concentration measurement using dual-energy computed tomography for the diagnosis of cardiac amyloidosis: a pilot study
    Virgile Chevance
    Thibaud Damy
    Vania Tacher
    François Legou
    Fourat Ridouani
    Alain Luciani
    Hicham Kobeiter
    Alain Rahmouni
    Jean-François Deux
    European Radiology, 2018, 28 : 816 - 823
  • [40] Study of the Natural Crystalline Lens Characteristics Using Dual-Energy Computed Tomography
    Sachs, Jeffrey R.
    Nahmias, Javier A.
    Hiatt, Kevin D.
    Bomar, James G.
    West, Thomas G.
    Bunch, Paul M.
    Benayoun, Marc D.
    Lack, Chris
    Thompson, Atalie C.
    DIAGNOSTICS, 2022, 12 (11)