Organ dose in cardiac dual-energy computed tomography: a Monte Carlo study

被引:0
|
作者
Pakravan, Delaram [1 ]
Mofrad, Farshid Babapour [1 ]
Deevband, Mohammad Reza [2 ]
Ghorbani, Mahdi [2 ]
Pouraliakbar, Hamidreza [3 ]
机构
[1] Islamic Azad Univ, Dept Med Radiat Engn, Sci & Res Branch, Tehran, Iran
[2] Shahid Beheshti Univ Med Sci, Sch Med, Biomed Engn & Med Phys Dept, Tehran, Iran
[3] Iran Univ Med Sci, Rajaie Cardiovasc Med & Res Ctr, Tehran, Iran
关键词
Monte Carlo simulation; Dual-energy computed tomography; Cardiac; Organ dose; Dose index; MULTIDETECTOR CT MDCT; IMAGE QUALITY; ANGIOGRAPHY; SCANNER; PATIENT; MODEL;
D O I
10.1007/s13246-021-01098-9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dual-energy computed tomography (DECT) has appeared as a novel approach with the aim of evaluating artery-related diseases. With the advent of DECT, concerns have been raised about the induction of diseases such as cancer due to high radiation exposure of patients. Therefore, the dose received by patients in DECT should be considered. The parameter most commonly used for patient dosimetry is the effective dose (ED). The purpose of this study is to model and validate a DECT scanner by a developed MCNP Monte Carlo code and to calculate the organ doses, the ED, and the conversion factor (k-factor) used in determining ED in the cardiac imaging protocol. To validate the DECT scanner simulation, a standard dosimetry body phantom was modeled in two radiation modes of single energy CT and DECT. The results of simulated CT dose index (CTDI) were compared with those of ImPACT or measurement data. Then dosimetry phantom was replaced by the male and female ORNL phantoms and the organ doses were calculated. The organ doses were also calculated by ImPACT dose software. In the initial validation stage, the minimum and maximum observed relative differences between results of MNCP simulation and measured were 2.77% and 5.79% for the central CTDI and 1.91% and 5.83% for the averaged peripheral CTDI, respectively. The mean ED of simulation and the ImPACT were 3.23 and 5.55 mSv/100 mAs, and the mean k-factor was 0.016 and 0.032 mSv mGy(-1) cm(-1) in the male and female phantoms, respectively. The k-factor obtained for males is close to the currently used k-factor, but the k-factor for females is almost twice.
引用
收藏
页码:157 / 166
页数:10
相关论文
共 50 条
  • [21] Dual-energy computed tomography: pediatric considerations
    Gallo-Bernal, Sebastian
    Pena-Trujillo, Valeria
    Gee, Michael S.
    PEDIATRIC RADIOLOGY, 2024, 54 (13) : 2112 - 2126
  • [22] Head and neck automatic multi-organ segmentation on Dual-Energy Computed Tomography
    Le, Anh Thu
    Sambourg, Killian
    Sun, Roger
    Deny, Nicolas
    Cifliku, Vjona
    Rouhi, Rahimeh
    Deutsch, Eric
    Fournier-Bidoz, Nathalie
    Robert, Charlotte
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 32
  • [23] The Feasibility of Dual-Energy Computed Tomography in Cardiac Contusion Imaging for Mildest Blunt Cardiac Injury
    Sade, Recep
    Kantarci, Mecit
    Ogul, Hayri
    Bayraktutan, Ummugulsum
    Uzkeser, Mustafa
    Aslan, Sahin
    Aksakal, Enbiya
    Becit, Necip
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (03) : 354 - 359
  • [24] Does dual-energy abdominal computed tomography increase the radiation dose to patients: a prospective observational study
    John, Dilip
    Athira, R.
    Selvaraj, Swathigha
    Renganathan, Rupa
    Gunasekaran, Kannan
    Arunachalam, Venkatesh Kasi
    POLISH JOURNAL OF RADIOLOGY, 2021, 86 : E208 - E216
  • [25] Optimization of energy level for coronary angiography with dual-energy and dual-source computed tomography
    Okayama, Satoshi
    Seno, Ayako
    Soeda, Tsunenari
    Takami, Yasuhiro
    Kawakami, Rika
    Somekawa, Satoshi
    Ishigami, Ken-ichi
    Takeda, Yukiji
    Kawata, Hiroyuki
    Horii, Manabu
    Uemura, Shiro
    Saito, Yoshihiko
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (04) : 901 - 909
  • [26] Estimation of Computed Tomography Dose Index (CTDI) Using Monte Carlo Simulation
    Talbi, Mohammed
    Aabid, Mohammed
    El Mansouri, M'hamed
    Nhila, Oussama
    Semghouli, Slimane
    Sebihi, Rajaa
    Choukri, Abdelmajid
    Khalis, Mohammed
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2021, 76 (SUPPL 1) : S103 - S109
  • [27] Dual-Energy Computed Tomography in Cardiothoracic Vascular Imaging
    De Santis, Domenico
    Eid, Marwen
    De Cecco, Carlo N.
    Jacobs, Brian E.
    Albrecht, Moritz H.
    Varga-Szemes, Akos
    Tesche, Christian
    Caruso, Damiano
    Laghi, Andrea
    Schoepf, Uwe Joseph
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (04) : 521 - +
  • [28] The value of dual-energy computed tomography in the evaluation of myocarditis
    Kantarci, Mecit
    Bayraktutan, Ummugulsum
    Akbulut, Abdusselam
    Taydas, Onur
    Ceviz, Naci
    Guven, Fadime
    Ogul, Hayri
    Aydin, Sonay
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2023, 29 (02): : 276 - 282
  • [29] Clinical Applications of Dual-Energy Computed Tomography in the Liver
    Kim, Sooah
    Shuman, William P.
    SEMINARS IN ROENTGENOLOGY, 2016, 51 (04) : 284 - 291
  • [30] Dual-Energy Computed Tomography for Gout Diagnosis and Management
    Nicola Dalbeth
    Hyon K. Choi
    Current Rheumatology Reports, 2013, 15