COMPARISON OF PROSTATE IMRT AND VMAT BIOLOGICALLY OPTIMISED TREATMENT PLANS

被引:60
作者
Hardcastle, Nicholas [1 ]
Tome, Wolfgang A.
Foo, Kerwyn
Miller, Andrew
Carolan, Martin
Metcalfe, Peter
机构
[1] Univ Wisconsin, Sch Med & Publ Hlth, Dept Human Oncol & Med Phys, Madison, WI 53792 USA
基金
美国国家卫生研究院;
关键词
VMAT; IMRT; Prostate; Biological Optimisation; SINGLE-ARC IMRT; VOLUMETRIC MODULATED ARC; BIOL-PHYS; 2008/70996-1001; CONFORMAL RADIOTHERAPY; COMPLICATION PROBABILITY; RADIATION-THERAPY; CANCER; DELIVERY; MODELS; TRIAL;
D O I
10.1016/j.meddos.2010.06.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Recently, a new radiotherapy delivery technique has become clinically available-volumetric modulated arc therapy (VMAT). VMAT is the delivery of IMRT while the gantry is in motion using dynamic leaf motion. The perceived benefit of VMAT over IMRT is a reduction in delivery time. In this study, VMAT was compared directly with IMRT for a series of prostate cases. For 10 patients, a biologically optimized seven-field IMRT plan was compared with a biologically optimized VMAT plan using the same planning objectives. The Pinnacle RTPS was used. The resultant target and organ-at-risk dose-volume histograms (DVHs) were compared. The normal tissue complication probability (NTCP) for the IMRT and VMAT plans was calculated for 3 model parameter sets. The delivery efficiency and time for the IMRT and VMAT plans was compared. The VMAT plans resulted in a statistically significant reduction in the rectal V25Gy parameter of 8.2% on average over the DIRT plans. For one of the NTCP parameter sets, the VMAT plans had a statistically significant lower rectal NTCP. These reductions in rectal dose were achieved using 18.6% fewer monitor units and a delivery time reduction of up to 69%. VMAT plans resulted in reductions in rectal doses for all 10 patients in the study. This was achieved with significant reductions in delivery time and monitor units. Given the target coverage was equivalent, the VMAT plans were superior. (C) 2011 American Association of Medical Dosimetrists.
引用
收藏
页码:292 / 298
页数:7
相关论文
共 50 条
  • [31] VMAT VS. 7-FIELD-IMRT: ASSESSING THE DOSIMETRIC PARAMETERS OF PROSTATE CANCER TREATMENT WITH A 292-PATIENT SAMPLE
    Kopp, Robert W.
    Duff, Michael
    Catalfamo, Frank
    Shah, Dhiren
    Rajecki, Michael
    Ahmad, Kehkashan
    MEDICAL DOSIMETRY, 2011, 36 (04) : 365 - 372
  • [32] The determination of optimal treatment plans for Volumetric Modulated Arc Therapy (VMAT)
    Dursun, Pinar
    Taskin, Z. Caner
    Altinel, I. Kuban
    EUROPEAN JOURNAL OF OPERATIONAL RESEARCH, 2019, 272 (01) : 372 - 388
  • [33] Dosimetric Comparison of IMRT and VMAT for Retinoblastoma Treatment: A treatment Planning Study
    Patil, Deepali
    Madhawi, Richa
    Zope, Mukesh K. U. M. A. R.
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2025, 40 (01): : 51 - 59
  • [34] Comparison of VMAT-SABR treatment plans with flattening filter (FF) and flattening filter-free (FFF) beam for localized prostate cancer
    Chung, Jin-Beom
    Kim, Jae-Sung
    Eom, Keun-Yong
    Kim, In-Ah
    Kang, Sang-Won
    Lee, Jeong-Woo
    Kim, Jin-Young
    Suh, Tae-Suk
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (06): : 302 - 313
  • [35] Complexity analysis of VMAT prostate plans: insights from dimensionality reduction and information theory techniques
    Kamperis, Efstathios
    Kodona, Chionia
    Papalexandrou, Apostolia
    Arsos, Georgios
    Heidich, Anna-Bettina
    Hatziioannou, Konstantinos
    Giannouzakos, Vasileios
    Papanastasiou, Emmanouil
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2023, 29 (03): : 143 - 150
  • [36] Effect of Photon-Beam Energy on VMAT and IMRT Treatment Plan Quality and Dosimetric Accuracy for Advanced Prostate Cancer
    Pasler, Marlies
    Georg, Dietmar
    Wirtz, Holger
    Lutterbach, Johannes
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 (12) : 792 - 798
  • [37] Evaluation of 3D-CRT, IMRT and VMAT radiotherapy plans for left breast cancer based on clinical dosimetric study
    Liu, Haiyun
    Chen, Xinde
    He, Zhijian
    Li, Jun
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2016, 54 : 1 - 5
  • [38] Evaluation of complexity and deliverability of prostate cancer treatment plans designed with a knowledge-based VMAT planning technique
    Wall, Phillip D. H.
    Fontenot, Jonas D.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (01): : 69 - 77
  • [39] Time and frequency to observe fiducial markers in MLC -modulated fields during prostate IMRT/VMAT beam delivery
    Xu, Qianqian
    Tong, Xu
    Lin, Muhan
    Chen, Xiaoming
    ElDib, Ahmed
    Lin, Teh
    Chen, Lili
    Ma, C-M Charlie
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 76 : 142 - 149
  • [40] Dosimetric and radiobiological comparison of prostate VMAT plans optimized using the photon and progressive resolution algorithm
    Chow, James C. L.
    Jiang, Runqing
    Xu, Lu
    MEDICAL DOSIMETRY, 2020, 45 (01) : 14 - 18