Intermaxillary Fixation Screw Morbidity in Treatment of Mandibular Fractures-A Retrospective Study

被引:9
作者
Florescu, Vlad Andrei [1 ]
Kofod, Thomas [2 ]
Pinholt, Else Marie [3 ]
机构
[1] Univ Copenhagen, Inst Clin Med, Copenhagen, Denmark
[2] Univ Copenhagen Hosp, Rigshosp, Dept Oral & Maxillofacial Surg, Copenhagen, Denmark
[3] Univ Southern Denmark, Univ Southern Denmark Hosp, Hosp South West Denmark, Inst Reg Hlth Sci,Fac Hlth Sci, Esbjerg, Denmark
关键词
SAGITTAL SPLIT OSTEOTOMY; ERICH ARCH BARS; MAXILLOMANDIBULAR FIXATION; BONE SCREWS; CONDYLAR FRACTURES; ROOT DAMAGE; MANAGEMENT; OUTCOMES; OSTEOSYNTHESIS; COMPLICATIONS;
D O I
10.1016/j.joms.2016.04.018
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of the present retrospective study was to investigate the morbidity of screws used for intermaxillary fixation (IMF) in the treatment of mandibular fractures. A review of the published data was also performed for a comparison of outcomes. Our hypothesis was that the use of screws for IMF of mandibular fractures would result in minimal morbidity. Materials and Methods: Patients treated for mandibular fractures from 2007 to 2013, using screws for IMF, using the international diagnosis code for mandibular fracture, DS026, were anonymously selected (Department of Oral and Maxillofacial Surgery, Rigshospitalet, University Hospital of Copenhagen, Copenhagen, Denmark). The fracture type, radiographic findings, treatment modality, screw type and number, and root damage were recorded. For the outcome comparison, a review of the published data regarding iatrogenic dental root damage caused by screw fixation was performed in May 2015. Results: A total of 156 patients had undergone IMF with screws. The total number of screws was 793. The incidence of root lesions was 0.25% centrally and 0.88% peripherally. The incidence of screw loss was 0.13% and that of screw loosening was 1.89%. In the review, 737 related reports were identified in a search of PubMed and the Cochrane Library. Of these, 25 were considered suitable for inclusion. A lack of valid evidence resulted in a descriptive analysis, because a meta-analysis of the data was not possible. Conclusions: The results of the present retrospective study have shown that the use of screws is a valid choice for IMF in mandibular fracture treatment with minimal morbidity. The 793 screws used for IMF resulted in a negligible amount of central and peripheral tooth root trauma. (C) 2016 American Association of Oral and Maxillofacial Surgeons
引用
收藏
页码:1800 / 1806
页数:7
相关论文
共 50 条
[31]   Bone-Supported Arch Bars Are Associated With Comparable Outcomes to Erich Arch Bars in the Treatment of Mandibular Fractures With Intermaxillary Fixation [J].
Chao, Albert H. ;
Hulsen, John .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 73 (02) :306-313
[32]   Effects of different mandibular fracture patterns on the stability of miniplate screw fixation in angle mandibular fractures [J].
Pektas, Z. O. ;
Bayram, B. ;
Balcik, C. ;
Develi, T. ;
Uckan, S. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2012, 41 (03) :339-343
[33]   Treatment of extracapsular fractures of the mandibular condylar process: A retrospective evaluation of 377 cases [J].
Maurer, Michael ;
Klaes, Tabea ;
Meier, Johannes K. ;
Gottsauner, Josef Maximilian ;
Taxis, Juergen ;
Schuderer, Johannes ;
Reichert, Torsten E. ;
Ettl, Tobias .
DENTAL TRAUMATOLOGY, 2023, 39 (06) :586-596
[34]   Predictors of screw cutout in the surgical fixation of peritrochanteric hip fractures: A retrospective cohort study [J].
Aboulebda, Mohanad ;
Salman, Loay A. ;
Hammad, Mohammad ;
Foodool, Mazin A. ;
Kong, Geraldine ;
Abunimer, Abdullah M. ;
Abu Hejleh, Hasan A. ;
Ahmed, Ghalib .
JOURNAL OF MUSCULOSKELETAL SURGERY AND RESEARCH, 2023, 7 (03) :164-169
[35]   A comparative study between traditional fixation with miniplates and modified lag screws for the treatment of mandibular fractures [J].
Garcia Carricondo, Ana Rocio ;
Quesada Bravo, Francisco Javier ;
Espin Galvez, Fernando ;
Parron Carreno, Tesifon ;
Alarcon Rodriguez, Raquel .
CLINICAL ORAL INVESTIGATIONS, 2018, 22 (03) :1503-1511
[36]   Comparison of bioabsorbable screw versus metallic screw fixation for tibial tubercle fractures in adolescents: a retrospective cohort study [J].
Chen, Tian ;
Wen, Yuwei ;
Zhu, Danjiang ;
Feng, Wei ;
Song, Baojian ;
Wang, Qiang .
BMC MUSCULOSKELETAL DISORDERS, 2025, 26 (01)
[37]   Dynamic Fixation versus Static Screw Fixation for Syndesmosis Injuries in Pronation External Rotation Ankle Fractures: A Retrospective Case Control Study [J].
Lim, C. M. ;
Choi, S. W. ;
Kim, B. S. ;
Lee, S. J. ;
Kang, H. S. .
MALAYSIAN ORTHOPAEDIC JOURNAL, 2023, 17 (03) :48-58
[38]   Comparison of the Outcomes of Plating, Screw Fixation, and Pinning in Sanders Type II Fractures: A Multicenter (TRON) Retrospective Study [J].
Kato, Mihoko ;
Takegami, Yasuhiko ;
Tokutake, Katsuhiro ;
Asami, Yuta ;
Takahashi, Yu ;
Takahashi, Hidetane ;
Kumagai, Hiroaki ;
Imagama, Shiro .
JOURNAL OF FOOT & ANKLE SURGERY, 2024, 63 (02) :171-175
[39]   Treatment of odontoid fractures with single anterior screw fixation [J].
Song, Kyung-Jin ;
Lee, Kwang-Bok ;
Kim, Ki-Nam .
JOURNAL OF CLINICAL NEUROSCIENCE, 2007, 14 (09) :824-830
[40]   Rigid versus Nonrigid Fixation for Bilateral Mandibular Angle Fractures: A Retrospective Multicenter Review [J].
Young, Thomas K. ;
Tuckett, Joel ;
Johnson, Nigel R. ;
Breik, Omar .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2024, 154 (04) :737e-744e