3D printed device including disk-based solid-phase extraction for the automated speciation of iron using the multisyringe flow injection analysis technique

被引:38
|
作者
Calderilla, Carlos [1 ,2 ]
Maya, Fernando [1 ]
Cerda, Victor [1 ]
Leal, Luz O. [2 ]
机构
[1] Univ Balearic Isl, Lab Environm Analyt Chem LQA2, Cra Valldemossa Km 7-5, Palma De Mallorca 07122, Spain
[2] Adv Mat Res Ctr, Environm & Energy Dept, Miguel de Cervantes 120, Chihuahua 31136, Mexico
关键词
3D printing; Solid-phase extraction; Multisyringe flow injection analysis; Automation; Water analysis; Iron determination; METAL-ORGANIC FRAMEWORKS; ENVIRONMENTAL-ANALYSIS; PLANAR CHROMATOGRAPHY; TRACE-ELEMENTS; WATER SAMPLES; SYSTEM; MICROEXTRACTION; SEAWATER; TRENDS; LEAD;
D O I
10.1016/j.talanta.2017.07.028
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of advanced manufacturing techniques is crucial for the design of novel analytical tools with unprecedented features. Advanced manufacturing, also known as 3D printing, has been explored for the first time to fabricate modular devices with integrated features for disk-based automated solid-phase extraction (SPE). A modular device integrating analyte oxidation, disk-based SPE and analyte complexation has been fabricated using stereolithographic 3D printing. The 3D printed device is directly connected to flow-based analytical instrumentation, replacing typical flow networks based on discrete elements. As proof of concept, the 3D printed device was implemented in a multisyringe flow injection analysis (MSFIA) system, and applied to the fully automated speciation, SPE and spectrophotometric quantification of Fe in water samples. The obtained limit of detection for total Fe determination was 7 ng, with a dynamic linear range from 22 ng to 2400 ng Fe (3 mL sample). An intra-day RSD of 4% (n = 12) and an inter-day RSD of 4.3% (n = 5, 3 mL sample, different day with a different disk), were obtained. Incorporation of integrated 3D printed devices with automated flow based techniques showed improved sensitivity (85% increase on the measured peak height for the determination of total Fe) in comparison with analogous flow manifolds built from conventional tubing and connectors. Our work represents a step forward towards the improved reproducibility in the fabrication of manifolds for flow-based automated methods of analysis, which is especially relevant in the implementation of interlaboratory analysis.
引用
收藏
页码:463 / 469
页数:7
相关论文
共 40 条
  • [21] 3D printed microplasma optical emission spectrometry coupled with ZIF-8 based dispersive solid-phase extraction for field analysis of waterborne arsenic
    Yang, Jiahui
    Lin, Yao
    Wang, Xi
    Li, Yuanyuan
    Deng, Yurong
    Zheng, Chengbin
    ANALYTICA CHIMICA ACTA, 2024, 1330
  • [22] A simple, fast and green nanofibers mat-based disk solid-phase extraction technique for chrysoidine analysis in soybean products
    Qi, Feifei
    Li, Xiaoqing
    Liu, Jingjing
    Huang, Kaiping
    Rong, Fei
    Xu, Qian
    ANALYTICAL METHODS, 2016, 8 (13) : 2837 - 2844
  • [23] A 3D printed centrifugal microfluidic platform for spilled oil enrichment and detection based on solid phase extraction (SPE)
    Zhang, Yong
    Xiang, Jiwen
    Wang, Yunxia
    Qiao, Zheng
    Wang, Wanjun
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 296
  • [24] 3D graphene–carbon nanotubes-based solid-phase extraction technique combined with GC–MS for the determination of organophosphorus pesticides in water samples
    Peng Sun
    Mengyao Liu
    Xiaolin Zhang
    Rui Yan
    Journal of the Iranian Chemical Society, 2020, 17 : 2275 - 2282
  • [25] An Imine-Based Porous 3D Covalent Organic Polymer as a New Sorbent for the Solid-Phase Extraction of Amphenicols from Water Sample
    Wei, Jinjian
    Chen, Lengbing
    Zhang, Rui
    Yu, Yi
    Ji, Wenhua
    Hou, Zhaosheng
    Chen, Yuqin
    Zhang, Zhide
    MOLECULES, 2023, 28 (08):
  • [26] Determination of phenols at low levels in water samples using automatic flow injection analysis coupled with on-line solid-phase extraction
    Sakai, T
    Fujimoto, S
    Higuchi, K
    Teshima, N
    BUNSEKI KAGAKU, 2005, 54 (12) : 1183 - 1188
  • [27] 3D graphene-carbon nanotubes-based solid-phase extraction technique combined with GC-MS for the determination of organophosphorus pesticides in water samples
    Sun, Peng
    Liu, Mengyao
    Zhang, Xiaolin
    Yan, Rui
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2020, 17 (09) : 2275 - 2282
  • [28] Extraction of volatile organic compounds liberated upon filament extrusion by 3D pen and its comparison with a desktop 3D printer using solid-phase microextraction fiber and Arrow
    Thapa, Bhawana
    Bell, David S.
    Anderson, Jared L.
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1719
  • [29] Simultaneous determination of neonicotinoids and fipronil and its metabolites in environmental water from coastal bay using disk-based solid-phase extraction and high-performance liquid chromatography-tandem mass spectrometry
    Li, Xiaotong
    Chen, Junhui
    He, Xiuping
    Wang, Zhiwei
    Wu, Danni
    Zheng, Xiaoling
    Zheng, Li
    Wang, Baodong
    CHEMOSPHERE, 2019, 234 : 224 - 231
  • [30] Trace multi-class organic explosives analysis in complex matrices enabled using LEGO®-inspired clickable 3D-printed solid phase extraction block arrays
    Irlam, Rachel C.
    Hughes, Cian
    Parkin, Mark C.
    Beardah, Matthew S.
    O'Donnell, Michael
    Brabazon, Dermot
    Barron, Leon P.
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1629